Tequipment
An InterWorld Highway, LLC Company
Call Us 1.877.571.7901
Hioki Clampmeters with Bluetooth
 
 
 
 
 

Fluke CNX i3000 iFlex AC Wireless Current Module

Fluke CNX I3000
Catalog #: 4221459
         
0 reviews
CNX WIRELESS IFLEX AC CURRENT MODULE
Free Gift From Fluke With Purchase

Features

  • True-RMS AC current measurements to 2500 A
  • 3% accuracy
  • Memory recording up to 65,000 readings
  • iFlex current probe allows you to get into tight, awkward spaces
  • Backlit LCD display
  • CAT IV 600 V, CAT III 1000 V
Loading Prices
List Price: $199.95
Loading Callouts
Request a Quote
Loading Series Compare

Product Information

 

The CNX i3000 iFlex AC Wireless Current Module is part of the Fluke team of wireless troubleshooting tools.

Connect the CNX i3000 iFlex AC Wireless Current Module to your test point, and view the results up to 20 meters away on the CNX Wireless Multimeter. You’ll save time, with less run-around, collecting multiple measurements. Use multiple modules for measurements on three-phase systems. Or use as a stand-alone measurement tool or combine with other CNX modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus, no more writing down data as the CNX i3000 Current Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.

Fluke CNX 3000 Series

  • Digital Multimeter
  • AC Voltage Module
  • AC True-rms Current Clamp Module
  • iFlex True-rms AC Current Clamp Module
  • K-Type Temperature Module
  • PC Adapter

Productivity

  • Save money and time by taking multiple measurements simultaneously
  • Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
  • Work with fewer interruptions by recording multiple sessions before downloading. Data is saved to a PC in .csv format (comma separated variable) file format for easy viewing at your convenience
  • Capture readings at different intervals, with user-set recording intervals from one second to one hour
  • Choose the module(s) that work best for your applications

Convenience

  • No more run-around. See up to four measurements (DMM and 3 modules) on one screen, in one place at the same time.
  • No more writing data down. Capture up to 65000 sets of min/max/avg readings over single or multiple logging sessions using the recording capability. Each reading and session is time stamped
  • Avoid awkward or uncomfortable measurement positions. Set up the measurement once, step back and read it as many times as you want, when you want
  • Identify up to 10 placed modules with meter or PC and choose only the ones you need
  • View up to 10 live readings at once on a PC to get a complete understanding of the situation
  • Easily see backlit displays in dark or dimly lit work environments
  • Choose auto or manual ranging
  • Use the optional TPak magnetic hanger for even more hands-free working
  • Integrated holster protects the meters, while probe holders keep accessories organized

Safety

  • Increase safety by taking readings in a separate location than the point of measurement
  • Fluke CNX meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards: AC current clamp 600 V CAT III; AC Voltage Module and iFlex Clamp Meters 600 V CAT IV / 1000 CAT III

Fluke CNX wireless test tools work together to help you solve problems faster. With the CNX team, measurements are:

  • remote
  • Simultaneous
  • recordable

The new Fluke wireless troubleshooting team lets you see live measurements from multiple modules simultaneously and remotely on a single screen. This customizable tool set, built with the durability, reliability and quality you’ve come to expect from Fluke tools, will change the way you work.

Wireless multimeter displays readings from up to three wireless modules, plus the meter from up to 20 meters away. Add a laptop and review ten measurements at once.

Possible Applications

Detecting power interruption measurement procedures Single phase measurement procedures
Determining current imbalance Measure incoming current

No More Run Around:

  • See up to four measurements (DMM and 3 modules) on one screen, in one place at the same time
  • Set up the modules and take the readings from up to 20 meters away
  • View and analyze readings from 10 tools at once on a PC to get a complete understanding of the situation

No More Writing Down:

  • Capture up to 65,000 sets of min/max/avg readings over single to multiple logging sessions using the recording capability

No More Waiting Around:

  • Save time and money by taking multiple measurements simultaneously
  • Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules

No More Uncomfortable Positions:

  • Set up the measurement once, step back and read it as many times as you want, when you want, from where you want
  • Increase safety by taking readings in a separate location from the point of measurement
  • Fluke CNX meets measurement category 1000 V CAT III and category IV 600 V safety standards

Fluke CNX™ Series  Wireless system

Your tools connected.
The new Fluke wireless trouble-shooting team works together to help you solve problems faster.

See live measurements from multiple modules simultaneously. Customize your tool set by mixing and matching to suit your unique testing needs and provide maxium flexibility.

Wireless will change the way you work

  • No more running around
  • Pen and paper no longer needed
  • No more waiting around
  • No more uncomfortable positions

Specifications

Detailed Specifications
Fluke CNX 3000 Series Wireless Multimeter
AC Voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of = 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range ¹ Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
))) 600 Ω 1 Ω Meter beeps at < 25 O, beeper detects opens or shorts of 250 µs or longer.
Ω 600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF ¹ 1 µF 10 %
¹ In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function Range ¹ Resolution Accuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range ¹ Resolution Accuracy
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale Typical short circuit current
To 6 MΩ 50 MΩ
1100 V RMS < 2.7 V DC < 0.7 V DC < 0.9 V DC < 350 mA
1100 V RMS < 2.7 V DC 2.000 V DC < 1.1 mA
Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration
General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54

 

Fluke CNX 3000 Series AC Voltage Module
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
6.000 V 0.001 V 1.0 % + 3 2.0 % + 3
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
¹ All AC voltage  ranges are specified  from 1 % of range  to 100  % of range.
² Crest factor of = 3 at full scale  up to 500  V, decreasing linearly  to crest  factor = 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add  –(2 % of reading + 2 % full scale) typical, for crest  factor up to 3.
General Specifications
LCD w/backlight 3½  digits, 6000 counts,  updates 4/sec
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400  Hours
Memory Record up to 65,000 readings
Unbound listen interval 5 seconds
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10  °C to +50 °C
Storage temperature -40  °C to +60 °C
Operating humidity 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600  V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008
Pollution degree 2
Temperature coefficient 0.1 X (specified  accuracy)/°C (< 18 °C or > 28 °C)
Safety rating CAT IV 600  V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size  (HxWxD) 16.5  cm x 6.35  cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)

 

General specifications
Fluke CNX a3000 AC Wireless Current Clamp Module
Range 400.0 A
Resolution 0.1 A
Accuracy 400.0 A: 2 % ± 5 digits (10 Hz to 100  Hz), 2.5 % ± 5 digits (100 Hz to 500  Hz)
Inrush Max displayed reading: 999.9A
Crest  factor (50 Hz/60 Hz) 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % for C.F. > 2
LCD w/backlight 3½  digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400  hours
Memory Record up to 65,000 readings
Unbound listen interval 5 seconds
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10  °C to +50 °C
Storage temperature -40  °C to +60 °C
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1-030:2010 to 600 V Measurement Category (CAT) III
EN/IEC 61010-2-030:2010
EN/IEC 61010-032:2002
Pollution degree 2
Temperature coefficient Add 0.1 x (specified  accuracy)/°C (< 18 °C or > 28 °C)
Safety rating CAT III 600  V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size  (HxWxD) 20.3  cm x 7.49  cm x 3.56 cm (8 in x 2.95  in x 1.4 in)
Weight .22 kg (8 oz)
Jaw opening 34 mm (1.33 in)

 

General specifications
Fluke CNX i3000 iFlex True-rms AC Current Clamp Module
Range 2500 A AC
Resolution 0.1 A
Accuracy 3 % ± 5 digits
Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display 3-1/2 digits,  LCD w/backlight
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory record up to 65,000 readings
Unbound listen interval 5 seconds
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree 2
Temperature coefficient Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm
(6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Jaw opening 25.4 cm (10 in) coil

 

General specifications
Fluke CNX t3000 K-Type Wireless Temperature Module
Range K-Type: -200 °C to 1372 °C
Resolution 0.1 °C
Accuracy ±[0.5 % + 0.3 °C] counts
Input terminals K-Type mini
LCD w/backlight 3 . digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
Unbound listen interval 5 seconds
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature scale ITS-90
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance CAT I per IEC/EN 61010-1:2010, EN/IEC 61010-2-030:2010
Pollution degree 2
Temperature coefficient 0.01 % of reading +0.03 °C per °C
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP30
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)

Reviews

CNX I3000 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
 
Most Helpful First | Newest First      Prev Page
 
Prev Page
 

Accessories

Loading Accessories

Fluke Price List

Fluke 376
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X