Fluke 87V Ex Intrinsically Safe True RMS Multimeter
Specifications
| General Specifications |
| Voltage DC |
| Maximum voltage |
1000 V |
| Accuracy |
± (0.05 % + 1) |
| Maximum resolution |
10 μV |
| Voltage AC |
| Maximum voltage |
1000 V |
| Accuracy |
± (0.7 % + 2) True-rms |
| AC bandwidth |
20 kHz |
| Maximum resolution |
10 μV |
| Current DC |
| Maximum amps |
10 A (20 A for 30 seconds maximum) |
| Amps accuracy |
± (0.2 % + 2) |
| Maximum resolution |
0.01 μA |
| Current AC |
| Maximum amps |
10 A (20 A for 30 seconds maximum) |
| Amps accuracy |
± (1.0 % + 2) |
| Maximum resolution |
True-rms 0.01 μA |
| Resistance |
| Maximum resistance |
50 MΩ |
| Accuracy |
± (0.2 % + 1) |
| Maximum resolution |
0.01 Ω |
| Capacitance |
| Maximum capacitance |
9,999 μF |
| Accuracy |
± (1 % + 2) |
| Maximum resolution |
0.001 nF |
| Frequency |
| Maximum frequency |
200 kHz |
| Accuracy |
± (0.005 % + 1) |
| Maximum resolution |
0.001 Hz |
| Duty Cycle |
| Maximum duty cycle |
99.90 % |
| Accuracy |
± (0.2 % per khz +0.1 %) |
| Maximum resolution |
0.10 % |
| Temperature |
| Range |
-200.0 °C to 1090 °C (-328 °F to 1994 °F) excluding probe |
| 80BK Temperature Probe |
| Range |
-40.0 °C to 260 °C (-40 °F to 500 °F) |
| Accuracy |
2.2 °C or 2 % whichever is greater |
| Conductance |
| Maximum conductance |
60.00 nS |
| Accuracy |
± (1.0 % + 10) |
| Maximum resolution |
0.001 nS |
| Diode |
| Range |
3 V |
| Resolution |
1 mV |
| Accuracy |
± (2 % + 1) |
| Duty Cycle Range |
| Accuracy |
Within ± (0.2 % per kHz + 0.1 %) |
| Measurements restriction in Ex-hazardous area |
| Voltage |
65 V |
| Current |
5 A |
| Environmental Specifications |
| Operating Temperature |
-20 °C to +50 °C |
| Storage Temperature |
-40 °C to +60 °C |
| Humidity (Without Condensation) |
0 % to 80 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 50 °C) |
| Operating Altitude |
2000 m |
| Safety Specifications |
| Overvoltage category |
EN 61010-1 to 1000 V CAT III, 600 V CAT IV |
| Agency Approvals |
CSA, TÜV |
| ATEX certification |
Ex II 2 G EEx ia IIC T4 |
| Agency Approvals |
ZELM 05 ATEX 0274 |
| Mechanical & General Specifications |
| Size |
201 x 98 x 52 mm (with holster) |
| Weight |
12,5 oz. (355 kg) with holster |
| Display (Digital) |
6000 counts updates 4/sec. 19,999 counts in high-resolution mod |
| Display (Analog) |
32 segments, updates 40/sec. |
| Warranty |
1 year |
| Battery Life |
~400 hours typical without backlight |
| Shock |
1 Meter drop per IEC 61010-1:2001 |
| Vibration |
Per MIL-PRF-28800 for a Class 2 instrument |
|