Our agents are available:
9:00 AM - 6:00 PM EST
Fluke 80T-IR
Non-Contact Infrared Temperature Probe
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Fluke 80T-IR
Non-Contact Infrared Temperature Probe



Click image to enlarge
The 80T-IR is compatible with any DMM with 10 MOhms input impedance, standard diameter banana jacks, and mV dc capability. Ideal for maintenance applications where object to be measured is hazardous to touch, is moving, easily contaminated, or difficult to reach.


Model Description List Price Sale Price
80T-IR INFRARED THERMOMETER PROBE - Discontinued - no replacement

     Click here to download the 80T-IR Instruction Sheet (PDF, 52kB)
     Click here to download the 80T-IR Instruction Sheet Supplement (PDF, 6kB)
     Click here to download the 80T-IR Calibration Information (PDF, 43kB)

  • Temperature Range: -18 to 260ºC (0 to 500ºF)
  • Accuracy: ± 3% of reading or ± 3ºC (±5ºF), whichever is greater, 18ºC to 28ºC (64ºF to 82ºF) ambient operating temperature.
  • Spot Size Ratio: 4:1
  • Minimum Spot Size: 0.1 inch diameter
  • Output Signal: 1mV per deg C or F (switchable)
  • Safety Rating: Complies with IEC Publication 1010-1-1990 including Ammendment 1, CSA C22.2 No. 231, ANSI/ISA-S82.01 and .03 Safety Standards.

     Looking for an accessory not listed here?
       Check the Fluke Accessory page or look on the Fluke Price List


   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET