| Display |
| Color transmissive LCD |
320 x 240 pixels (70 mm diagonal) with 2 level backlight |
| Power supply |
| Battery type |
1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
| Battery life |
typically > 10 hours (backlight on full) > 12 hours (backlight reduced) |
| Battery Eliminator BE345 |
Input: 110 V/230 V, 50/60 Hz Output: 15 V dc, 300 mA |
| Ambient conditions (For indoor use only) |
| Reference conditions |
All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F) |
| Operating temperature |
0 °C to 50 °C (32 °F to 122 °F) |
| Temperature coefficient of current |
≤ ± 0.15 % of rdg per °C |
| Temperature coefficient of voltage |
≤ ± 0.15 % of rdg per °C |
| Maximum relative humidity |
80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F) |
| Maximum operating altitude |
2000 m |
| Electrical safety |
| Safety Rating |
IEC 61010-1 600 V CAT IV, double or reinforced insulation, pollution degree 2 Protection IP40; EN60529 |
| Maximum safe working voltages |
| Current measurement |
600 V ac rms or dc between uninsulated conductor and ground |
| Voltage measurement |
600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
| EMC |
| Emission |
IEC/EN 61326-1:1997 class B |
| Immunity |
IEC/EN 61326-1:1997 |
| Mechanical |
| Dimensions (length x width x depth) |
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
| Weight including batteries |
820 g/1.8 lb |
| Jaw opening |
60 mm |
| Jaw capacity |
58 mm diameter |
| Cleaning |
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or |
| other solvents. |
| Electrical data |
| All accuracies stated at |
23 °C ± 1 °C (73.4 °F ± 1.8 °F). |
| See Ambient conditions specifications for temperature coefficients. |
| Current measurement (dc, dc rms, ac rms) |
| Measuring range |
0 to 2000 A dc or 1400 ac rms |
| Autorange facility |
40 A/400 A/2000 A |
| Resolution |
10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
| Accuracy |
| DC and dc rms |
| I > 10 A |
± 1.5 % rdg ± 5 digits |
| I < 10 A |
± 0.2 A |
| AVG |
| I > 10 A |
± 3 % rdg ± 5 digits |
| I < 10 A |
± 0.5 A |
| Pk |
| I > 10 A |
± 5 % rdg ± 5 digits |
| I < 10 A |
± 0.5 A |
| AHr |
| I > 10 A |
± 2 % rdg ± 5 digits |
| I < 10 A |
± 0.5 AHr |
| CF (Crest Factor) |
| 1.1 ≤ CF < 3 |
± 3 % rdg ± 5 digits |
| 3 ≤ CF < 5 |
± 5 % rdg ± 5 digits |
| Resolution |
0.01 |
| RPL (Ripple) |
| 2 % ≤ RPL < 100 % |
± 3 % rdg ± 5 digits |
| 100 % ≤ RPL < 600 % |
± 5 % rdg ± 5 digits |
| Resolution |
0.1 % |
| |
Idc > 5 A |
| |
Iac > 2 A |
All measurements dc and 15 Hz to 1 kHz Maximum overload 10,000 A or rms x frequency < 400,000 Amps rms is a true-rms measurement (ac + dc) |
| Voltage measurement (dc, dc rms, ac rms) |
| Measuring range |
0 to 825 V dc or ac rms |
| Autorange facility |
4 V/40 V/400 V/750 V |
| Resolution |
1 mV in 4 V range 10 mV in 40 V range 100 mV in 400 V range 1 V in 750 V range |
| Accuracy |
| DC and dc rms |
| V > 1 V |
± 1 % rdg ± 5 digits |
| V < 1 V |
± 0.02 V |
| AVG |
| V > 1 V |
± 3 % rdg ± 5 digits |
| V < 1 V |
0.03 V |
| Pk |
| V > 1 V |
± 5 % rdg ± 5 digits |
| V < 1 V |
± 0.03 V |
| CF (Crest Factor) |
| 1.1 ≤ CF < 3 |
± 3 % rdg ± 5 digits |
| 3 ≤ CF < 5 |
± 5 % rdg ± 5 digits |
| Resolution |
0.01 |
| RPL (Ripple) |
| 2 % ≤ RPL < 100 % |
± 3 % rdg ± 5 digits |
| 100 % ≤ RPL < 600 % |
± 5 % rdg ± 5 digits |
| Resolution |
0.1 % |
| |
Vdc > 0.5 V |
| |
Vac > 0.2 V |
All measurements dc and 15 Hz to 1 kHz Maximum overload 1,000 V rms Volts rms is a true-rms measurement (ac + dc) |
| Harmonics |
| THD (Total Harmonic Distortion) |
| 1 % ≤ THD < 100 % |
± 3 % rdg ± 5 digits |
| 100 % ≤ THD < 600 % |
± 5 % rdg ± 5 digits |
| Resolution |
0.1 % |
| DF (Distortion Factor) |
| 1 % ≤ DF < 100 % |
± 3 % rdg ± 5 digits |
| Resolution |
0.1 % |
| H02 ≤ Vharm < H13 |
± 5 % rdg ± 2 digits |
| H13 ≤ Vharm ≤ H30 |
± 10 % rdg ± 2 digits |
All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz) Frequency range F0 15 Hz to 22 Hz and 45 Hz to 65 Hz Vacrms > 1V |
| Watts measurement (single- and three-phase) (dc, dc rms, ac rms) |
| Measuring range |
0 to 1650 kW dc or 1200 kW ac |
| Autoranging facility |
4 kW, 40 kW, 400 kW, 1650 kW ac |
| Resolution |
1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW |
| Accuracy |
2.5 % rdg ± 5 digits W1Ø < 2 kW ± 0.08 kW W3Ø < 4 kW ± 0.25 kW |
| VA measurement (single- and three-phase) (dc, dc rms, ac rms) |
| Measuring range |
0 to 1650 kVA dc or 1200 kVA ac |
| Autorange facility |
4 kVA, 40 kVA, 400 kVA, 1650 kVA |
| Resolution |
1 VA in 4 kVA 10 VA in 40 kVA 100 VA in 400 kVA 1 kVA in 1200 kVA |
| Accuracy |
| VA > 2 kVA |
2.5 % rdg ± 5 digits |
| VA < 2 kVA |
± 0.08 kVA |
| VAR measurement (single- and three-phase) |
| Measuring range |
0 to 1250 kVAR |
| Autorange facility |
4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR |
| Resolution |
1 VAR in 4 kVAR 10 VAR in 40 kVAR 100 VAR in 400 kVAR 1 kVAR in 1200 kVAR |
| Accuracy |
| VAR > 4 kVAR |
± 2.5 % rdg ± 5 digits |
| VAR < 4 kVAR |
± 0.25 kVAR |
| Power factor range 0.3 < PF < 0.99 |
| Power factor (single- and three-phase) |
| Power factor |
| Measuring range |
0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive) |
| Resolution |
0.001 |
| Accuracy |
± 3° |
| Frequency range |
15 Hz to 1 kHz |
| Displacement power factor |
| Measuring range |
0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive) |
| Resolution |
0.001 |
| Accuracy |
± 3° |
| Frequency range |
15 Hz to 22 Hz and 45 Hz to 65 Hz |
| Kilowatt hour (kWHr) |
| Measuring range |
40,000 kWHr |
| Autorange facility |
1 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr Resolution 1 WHr in 4 kWHr 10 WHr in 40 kWHr 100 WHr in 400 kWHr 1 kWHr in 4,000 kWHr 10 kWHr in 40,000 kWHr |
| Accuracy |
| kWHr > 2 kWHr |
± 3 % ± 5 digits |
| kWHr < 2 kWHr |
± 0.08 kWHr |
| All Watts /VA /VAR /PF measurements |
| Frequency range |
DC and 15 Hz to 1 kHz |
| Current range |
10 A to 1400 A rms |
| Voltage range |
1 V to 825 V rms |
| Maximum input |
825 V rms/1400 A rms |
| Maximum overload |
1000 V rms/10,000 A |
| Frequency measurement (from current or voltage sources) |
| Measuring range |
15 Hz to 1 kHz |
| Resolution |
0.1 Hz |
| Accuracy |
15 to 22 Hz ± 0.5 % rdg 40 Hz to 70 Hz ± 0.5 % rdg 15 Hz to 1000 Hz ± 1% rdg |
| Current range |
10 A to 1400 A rms |
| Voltage range |
1 V to 825 V rms |
| Scope function |
| Current measurement |
| Ranges |
10 A/20 A/40 A/100 A/200 A/400 A/1000 A/2000 A |
| Resolution |
1 A in 40 A 10 A in 400 A 50 A in 2000 A |
| Accuracy |
± 3 % rdg ± 1 pixel |
| Maximum overload |
10,000 A |
| Voltage measurement |
| Ranges |
4 V/10 V/20 V/40 V/100 V/200 V/400 V/1000 V |
| Resolution |
100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
| Accuracy |
± 2 % rdg ± 1 pixel |
| Maximum overload |
1000 V rms |
| Frequency range |
DC and 15 Hz to 600 Hz |
| Time base |
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div |
| Refresh rate |
0.5 seconds |
| Maximum sampling rate |
15.625 kHz |
| Inrush current function |
| Ranges |
40 A, 400 A, and 2000 A |
| Resolution |
10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
| Accuracy |
| I > 10 A |
± 5 % rdg ± 1 pixel |
| I < 10 A |
± 0.5 A |
| All measurements dc and 15 Hz to 1 kHz |
| Maximum overload |
Maximum overload 10,000 A or rms x frequency < 400,000 |
| Amps rms is a true-rms measurement (ac + dc) |
| Capture time |
1 s, 3 s, 10 s, 30 s, 100 s, and 300 s |
| Maximum sampling rate |
15.625 kHz |
| Interface |
| USB Interface to a PC |
| Power Log software for download, analysis, and reporting |
| 345 Upgrade Utility for installing a new firmware version |
| Logging Memory |
| Logging areas |
Three areas that can be used individually or combined into one large area |
| Averaging periods |
1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom |
| Logging times |
| Volts and current mode |
| Average time Logging time (1 area) Logging time (3 areas) |
| 1 s |
1 h 49 m |
5 h 12 m |
| 2 s |
3 h 38 m |
10 h 24 m |
| 5 s |
9 h 06 m |
1 d 2 h 00 m |
| 10 s |
18 h 12 m |
2 d 04 h 00 m |
| 30 s |
2 d 06 h 36 m |
6 d 12 h 01 m |
| 1 min |
4 d 13 h 12 m |
13 d 00 h 03 m |
| 5 min |
22 d 18 h 00 m |
65 d 00 h 15 m |
| 10 min |
45 d 12 h 00 m |
130 d 00 h 30 m |
| 15 min |
68 d 06 h 00 m |
195 d 00 h 45 m |
| V & A harmonics mode |
| Average time Logging time (1 area) Logging time (3 areas) |
| 1 s |
0 h 34 m |
1 h 38 m |
| 2 s |
1 h 08 m |
3 h 16 m |
| 5 s |
2 h 52 m |
08 h 11 m |
| 10 s |
5 h 44 m |
16 h 23 m |
| 30 s |
17 h 13 m |
2 d 01 h 11 m |
| 1 min |
1 d 10 h 26 m |
4 d 02 h 23 m |
| 5 min |
7 d 04 h 10 m |
20 d 11 h 25 m |
| 10 min |
14 d 08 h 20 m |
81 d 0 h 50 m |
| 15 min |
21 d 12 h 30 m 121 |
d 13 h 15 m |
| single- and three-phase power mode |
| Average Time Logging Time (1 area) Logging Time (3 areas) |
| 1 s |
1 h 40 m |
4 h 47 m |
| 2 s |
3 h 21 m |
9 h 34 m |
| 5 s |
8 h 22 m |
23 h 57 m |
| 10 s |
16 h 45 m |
1 d 23 h 54 m |
| 30 s |
2 d 02 h 17 m |
5 d 23 h 42 m |
| 1 min |
4 d 04 h 35 m 11 |
d 23 h 25 m |
| 5 min |
20 d 22 h 55 m |
59 d 21 h 05 m |
| 10 min |
41 d 21 h 50 m |
119 d 18 h 10 m |
| 15 min |
62 d 20 h 45 m |
179 d 15 h 15 m |