Tequipment
An InterWorld Highway, LLC Company
Call Us 1.877.571.7901
Flir Ex Thermal Imagers
 
 
 
 
 

Fluke 1529-R-156 Chub-E4 Thermometer

Fluke 1529-R-156
Catalog #: 1672247
         
0 reviews
THERMOMETER,CHUB-E4,4-PRT/THERMISTOR
Free Gift From Fluke With Purchase

Features

  • Logs up to 8,000 readings with date and time stamps
  • Battery provides eight hours of continuous operation
  • Four channels for PRTs, thermistors, and thermocouples
  • Displays eight user-selected data fields from any channel
Loading Prices
Sale: $5,155.00
  + Free shipping over $99

Marketing-Promo-Add-to-Cart-176x92-3-items

Loading Callouts
Request a Quote
Loading Series Compare

Compare Products in this Series

Product Name Unique Features Warranty Details Additional Info/Comments Availability Price  
1529-R-156
1529-R-156
THERMOMETER,CHUB-E4,4-PRT/THERMISTOR
Chub-E4 has four inputs for reading four different sensors simultaneously One-, two-, and four-year<br>plans available 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering Availability
in stock!
Edu Price Standard Price Gov't Price
1529-156
1529-156
THERMOMETER,CHUB-E4,2-PRT,2-TC
Chub-E4 has four inputs for reading four different sensors simultaneously One-, two-, and four-year<br>plans available 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering Availability
in stock!
Edu Price Standard Price Gov't Price
1529-T-156
1529-T-156
THERMOMETER,CHUB-E4,4-TC INPUTS
Chub-E4 has four inputs for reading four different sensors simultaneously One-, two-, and four-year<br>plans available 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering Availability
in stock!
Edu Price Standard Price Gov't Price

Product Information

1529-R-156 Chub-E4 Thermometer, 4 PRT/Thermistor inputs

Lab-quality accuracy on four channels for PRTs, thermistors and thermocouples

So you need multiple channels, battery power, outstanding accuracy, and the ability to read many different sensor types—but you don’t need all the power of a 1 ppm Super-Thermometer. We have the answer for you.

Fluke Calibration’s 1529 Chub-E4 Thermometer gives you four channels, three major sensor types, lab-quality accuracy, and a ton of great features, all at a price you’ll love.

Inputs

The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways according to your preference. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem.

100-ohm, 25-ohm, or 10-ohm PRTs and RTDs are read using ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods. Typical accuracies include ±0.004 °C at –100 °C and ±0.009 °C at 100 °C. Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025 °C at 25 °C with resolution of 0.0001 °.

Thermocouple inputs read all the common thermocouple types, including B, E, J, K, N, R, S, T, and Au-Pt, and allow you to choose between internal and external reference junction compensation. Typical accuracy for a type J thermocouple at 600 °C is ±0.35 °C using internal reference junction compensation and not including the thermocouple. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples.)

PRTs and thermistors connect easily to the 1529 using Fluke Calibration’s patented mini DWF connectors, which accept bare wire, spade lug, or mini banana plug terminations. Thermocouples connect using standard or miniature terminations. Measurements are taken each second and can be taken simultaneously or sequentially. A special high-speed mode allows measurements on one channel to be taken at the rate of 10 per second.

Display

If you think three sensor types and four inputs sounds versatile, wait until you see the display panel on the Chub-E4. Displaying measurements in °C, °F, K, ohms, or millivolts and choosing temperature resolution from 0.01 to 0.0001 are just the beginning.

You can also select any eight items from our long list of displayable data fields to view on-screen. Choose statistical functions such as averages, standard deviations, and spreads; choose probe information such as probe type and serial number; choose T1–T2 functions using inputs from any two channels; or choose utility functions such as the date, time, and battery power level. You can even save up to 10 screen configurations for easy recall.

The push of a single front-panel button also brings up a simple menu system to easily guide you through all the internal setup and memory options of the 1529. Probe coefficients, sample intervals, communication settings, password settings, and a host of other functions are all easily accessible.

Communications

The memory and communications capabilities of the Chub-E4 make it perfect for benchtop thermometry, on-site measurements, lab calibration work, and remote data logging. Optional software packages from Fluke make this one of the most powerful thermometers on the market.

With battery power and memory to store up to 8,000 measurements (including date and time stamps) at user-selected intervals, the 1529 has plenty of data logging capability. Store 100 individual measurements or any number of automatic log sessions (up to 8,000 readings), each tagged with an identifying session label. Fourteen different logging intervals may be selected, from 0.1 second to 60 minutes.

With Fluke Calibration’s 9935 LogWare II, data may be quickly downloaded to your PC for complete graphical and statistical analysis. Separate log sessions may even be automatically downloaded to separate files based on session labels. With this software, the 1529 can even be used for real-time data logging. Log four channels at once directly to your PC with virtually no limit to the number of data points you take. You can analyze data, set alarm events, and even set delayed start and stop times.

With MET/TEMP II software, the Chub-E4 may be integrated into a completely automated calibration system. Use one input for your reference thermometer and calibrate up to three other thermometers automatically (see page 81). An RS-232 port is standard on every unit. An IEEE-488 port is optional.

More great features

Did we forget some aspect of versatility on this thermometer? No!

The 1529 runs on AC power from 100 to 240 volts, DC power from 12 to 16 volts, or off its internal nickel-metal-hydride battery for eight hours between charging. The standard battery charges in less than three hours and lasts through 500 charge/recharge cycles.

If you want to rack-mount your Chub-E4, we’ve even got a rack-mount kit for you. This unit fits on your benchtop, in your instrument rack, and even in your hand.

Of course, all the reference thermometers you might need for your 1529 are available from Fluke, including secondary standard PRTs, standard thermistors, and noble-metal thermocouples. Carrying cases and even a serial printer for direct printer output are also available.

We’ve said it before and we’ll keep saying it: Fluke Calibration simply makes the best thermometer readouts in the world. No one else gives you a comparable combination of accuracy, versatility, productivity-enhancing features, and price. No one. Get a Chub-E4 and just enjoy everything it’ll do for you. You’ll love it.

Specifications

Specifications
  PRT / RTD Thermistor Thermocouple
Inputs 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering; PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available.
Temperature Range –189 °C to 960 °C –50 °C to 150 °C –270 °C to 1800 °C
Measurement Range 0 to 400 W 0 to 500 KW –10 to 100 mV
Characterizations ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen Steinhart-Hart, YSI-400 NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial
Temperature Accuracy (meter only) ± 0.004 °C at –100 °C
± 0.006 °C at 0 °C
± 0.009 °C at 100 °C
± 0.012 °C at 200 °C
± 0.018 °C at 400 °C
± 0.024 °C at 600 °C
± 0.0025 °C at 0 °C
± 0.0025 °C at 25 °C
± 0.004 °C at 50 °C
± 0.010 °C at 75 °C
± 0.025 °C at 100 °C
Ext. RJC Int. RJC
B at 1000 °C ± 0.6 °C ± 0.6 °C
E at 600 °C ± 0.07 °C ± 0.25 °C
J at 600 °C ± 0.1 °C ± 0.35 °C
K at 600 °C ± 0.15 °C ± 0.4 °C
N at 600 °C ± 0.15 °C ± 0.3 °C
R at 1000 °C ± 0.4 °C ± 0.5 °C
S at 1000 °C ± 0.5 °C ± 0.6 °C
T at 200 °C ± 0.1 °C ± 0.3 °C
Temperature Resolution 0.001 ° 0.0001 ° 0.01 to 0.001 °
Resistance/Voltage Accuracy 0 W to 20 W: ± 0.0005W 20 W to 400 W: ± 25 ppm of rdg 0 W to 5 KW: ± 0.5 W 5 KW to 200 KW: ± 100 ppm of rdg. 200 KW to 500 KW ± 300 ppm of rdg. –10 to 50 mV: ± 0.005 mV 50 to 100 mV: ± 100 ppm of rdg. Internal RJC: ± 0.25 °C)
Operating Range 16 °C to 30 °C
Measurement Interval 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval
Excitation Current 1 mA, reversing 2 and 10 µA, automatically selected n/a
Display 33 x 127 mm (1.3 x 5 in) backlit LCD graphical display
Display Units °C, °F, K, W, KW, mV
Data Logging Up to 8,000 time- and date-stamped measurements can be logged
Logging Intervals 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
Averaging Moving average of most recent 2 to 10 readings, user selectable
Probe Connection Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations Universal receptacle accepts miniature and standard TC connectors
Communications RS-232 included, IEEE-488 (GPIB) optional
AC Power 100–240 V ac, 50-60 Hz, 0.4 A
DC Power 12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A)
Battery NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles
Size (HxWxD) 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in)
Weight 2 kg (4.5 lb)
Calibration Accredited NIST-traceable resistance calibration and NIST-traceable voltage calibration provided

Reviews

Fluke 1529-R-156 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
 
Most Helpful First | Newest First      Prev Page
 
Prev Page
 

Accessories

Loading Accessories

Fluke Price List

X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X