Fluke 1520 MegOhmMeter
| Technical Data |
| Auto ranges |
Range: 4 MW, 40 MW, 400 MW, 4000 MW
Accuracy to 100 MW: 2% + 2 counts
over 100 MW: 10% + 2 counts +1% / GW
Resolution: 0.001MW to 10 MW |
| Test voltages |
Range: 250V, 500V, 1000V
Accuracy: +20%, -0% |
| Max measurement current |
1 mA |
| Audible/visible voltage warning |
³ 30V ac or dc |
| Lo-Ohms resistance |
Range: O to 40W
Accuracy: 2% + 2 counts
Resolution: 0.01W |
| Lo-Ohms analog bar graph |
0 to 100W |
| Lo-Ohms audible / visible voltage warning |
³ 30V ac or dc |
| Resistance |
Range: 4 k W
Accuracy: 2% + 2 counts
Resolution: 1W |
| Analog bar graph |
0 to 10kW |
| Voltage |
Range: 0 to 600V ac (50/60 Hz), 0 to 600V dc
Accuracy: 2% + 2 counts
Resolution: 1V |
| Safety Specifications |
| Electrical safety |
Meets IEC 1010-1 and EN 61557 |
| Protection class |
Pollution degree II |
| Overvoltage category |
IEC 1010-1 CAT III 600V |
| Agency approvals |
UL, CSA, TUV (pending) |
| Environmental Specifications |
| Operating temperature |
-10°C to +50°C |
| Storage temperature |
-40°C to +70°C |
| Humidity (without condensation) |
75% RH (40°C) |
| Dust / water resistance |
IP42 per IEC 529 |
| Operating altitude |
2,500 meters (7,500 feet) |
| Mechanical & General Specifications |
| Battery check function |
Indicates remaining percent of charge |
| Size |
241 x 108 x 72mm (9.5 x 4.25 x 2.85 inches) |
| Weight |
1.1 kg (2.5 lbs) |
| Batteries |
4 C size 1.5V alkaline |
| Warranty |
3 years |
|
|
|
|