Fluke 116-322 HVAC Combo Kit

Click image to enlarge
Fluke 116/322 KIT
|
Includes
- Fluke 116 Multimeter with Temperature
- Fluke 322 Compact Clamp Meter
- Fluke 80AK Thermocouple Adapter
- Fluke 80PK-1 Thermocouple Bead Probe
- Fluke 80PK-11 Flexible Pipe Clamp Thermocouple
- Fluke C115 Deluxe Carrying Case with Shoulder Strap
- Fluke TL75 Hard Point Test Lead Set
- Fluke TPAK ToolPak Magnetic Meter Hanging Kit
- 3-year product warranty on Fluke-116 DMM, 2-year warranty on Fluke-322 Clamp Meter and 1-year warranty on accessories
|
Features
Fluke 116 HVAC True Rms Multimeter:
- Built in thermometer for HVAC applications
- Microamps to test flame sensors
- LoZ: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak)
- CAT III 600 V safety rated
Fluke 322 Compact Clamp Meter:
- Precise low current measurements with better than 2% basic accuracy
- Safety rating: IEC 1010-2-031, 600 V CAT III
- Controls positioned for one-hand operation
- Auto shut-off
- Display hold
- Includes (2) AAA batteries, test leads, instruction card, safety information and soft carrying case
- Two-year warranty
Fluke TL75 Hard Point Test Lead Set:
- Extremely hard alloy tips resist wear
- Distinctive comfort grip probes
- Economical PVC insulated leads
- Cat III, 1000V, 10A
Fluke 80AK-A Thermocouple Adapter:
- Allows the Fluke-16, Fluke-78, Fluke-89-IV, Fluke-179, Fluke-187 and Fluke-189 multimetes to be used with any K-type thermocouple probe.
- The 80AK-A adapter does not affect measurement range and accuracy.
Fluke 80PK-1 General Purpose Bead Probe:
- 80PK-1 is compatible with K-type thermometers; 80PJ-1 works with J-Type thermometers
- Measurement range: -40 to 260ºC (-40 to 500ºF)
Fluke 80PK-11 Velcro Pipe Clamp Thermocouple:
- Designed for hands free measurement of HVAC temperature measuring applications
- Use multiple and leave in place for route based routine maintenance
- Use with any temperature-measuring instrument designed to accept Type-K thermocouples
Fluke ToolPak Magnetic Meter Hanging Strap:
- Kit includes, universal hanger clips (2), hook & loop straps (2 lengths) and strong magnet
- Combine components to meet most hanging needs
- Attaches to back of a 110/170/180 Series meter, 20/70 -III with integrated holster (with adapter), 724/725 and 50 Series II
- One year warranty
|
Description
This new kit is a direct replacement for the obsolete 16/322 HVAC combo kit.
For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
Specifications
| Maximum voltage between any terminal and earth ground |
600 V |
| Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| Display |
Digital: 6,000 counts, updates 4/sec |
| Bar graph |
33 segments, updates 32/sec |
| Operating temperature |
-10 °C to + 50 °C |
| Storage temperature |
-40 °C to + 60 °C |
| Battery |
9 volt Alkaline, NEDA 1604A/IEC 6LR61 |
| Battery life |
400 hours typical, without backlight |
| Measurement |
Range |
Resolution |
Accuracy ± ([% of reading] + [counts]) |
| DC millivolts |
600.0 mV |
0.1 mV |
2.0 % + 3 |
| DC volts |
6.000 V |
0.001 V |
|
| 60.00 V |
0.01 V |
| 600.0 V |
0.1 V |
| Auto volts |
600.0 V |
0.1 V |
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms |
600.0 mV |
0.1 mV |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms |
6.000 V |
0.001 V |
1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| 60.00 V |
0.01 V |
| 600.0 V |
0.1 V |
| Continuity |
600 Ω |
1 Ω |
Beeper on < 20 O off > 250 Ω; detects opens or shorts of 500 µs or longer. |
| Ohms |
600.0 Ω |
0.1Ω |
0.9 % + 2 |
| 6.000 kΩ |
0.001 kΩ |
0.9 % + 1 |
| 60.00 kΩ |
0.01 kΩ |
| 600.0 kΩ |
0.1 kΩ |
| 6.000 MΩ |
0.001 MΩ |
| 40.00 MΩ |
0.01 MΩ |
1.5 % + 2 |
| Diode test |
2.000 V |
0.001 V |
0.9 % + 2 |
| Capacitance |
1000 nF |
1 nF |
1.9 % + 2 |
| 10.00 µF |
0.01 µF |
| 100.0 µF |
0.1 µF |
| 9999 µF |
1 µF |
|
| 100 µF to 1000 µF |
|
1.9 % + 2 |
| > 1000 µF |
|
5 % + 20 |
| Lo-Z capacitance |
1 nF to 500 µF |
|
10 % + 2 typical |
| Temperature2 (Type-K thermocouple) |
-40 °C to 400 °C |
0.1 °C |
1 % + 102 |
| -40 °F to 752 °F |
0.2 °F |
1 % + 182 |
| AC µamps true-rms (45 Hz to 500 Hz) |
600.0 µA |
0.1 µA |
1.5 % + 3 (2.5 % + 3 > 500 Hz) |
| DC µamps |
600.0 µA |
0.1 µA |
1.0 % + 2 |
| Hz (V or A input)3 |
99.99 Hz |
0.01 Hz |
0.1 % + 2 |
| 999.9 Hz |
0.1 Hz |
| 9.999 kHz |
0.001 kHz |
| 50.00 kHz |
0.01 kHz |
Back to Top
| General Specifications |
| Min/Max |
No |
| Backlight |
No |
| Operating Temperature |
-14 °F to 122 °F (-10 °C to 50 ° C) |
| Battery Life |
(2) AAA carbon zinc approximately 100 hours continuous, automatic low battery indicator. |
| Safety Rating |
IEC 1010-2-031, 600 V CAT III |
| Warranty |
Two years |
| Temperature De-rating |
< 18 °C, > 28 °,C add 0.1 x specified accuracy / °C |
| Storage Temperature |
-22 °F to 140 °F (-30 °C to 60 °C) |
| Display Hold |
Yes |
| Weight |
8 oz. (224 g) |
| Size |
Height |
7.5" (19.05 cm) |
| Width |
2.5" (6.35 cm) |
| Depth |
1.4" (3.50 cm) |
| Jaw Opening |
1" (2.54 cm) |
| Technical Specifications |
| AC Current |
Range |
0 - 40.00 A, 40.0 - 400.0 A |
| Accuracy |
1.8% ± 5 counts (50 - 60 Hz) 3.0% ± 5 counts (60 Hz - 400 Hz) |
| AC Response |
Averaging |
| AC Volts |
Range |
0 - 400.0 V, 400 - 600 V |
| Accuracy |
1.2% + 5 counts (50 - 400 Hz) |
| AC Response |
Averaging |
| DC Volts |
Range |
0 - 400.0 V, 400 - 600 V |
| Accuracy |
1% + 5 counts |
| Resistance |
Range |
0-400.0 Ohms |
| Accuracy |
1% ± 5 counts |
| Continuity |
≤ 30 Ohms |
|
|