Tequipment
An InterWorld Highway, LLC Company
Call Us 1.877.571.7901
Pico 2204A PicoScope 2 channel + AWG, 10MHz
 
 
 
 
 

Fluke 190-504/AM Color ScopeMeter, 500 MHz, 4 channels

Fluke 190-504/AM
Catalog #: 4419882
         
0 reviews
SCOPEMETER 4CH 500MHZ COLOR AMERICAS

Click to Listen - Top Features

Free Gift From Fluke With Purchase
FREE battery pack & carrying case
with purchase

Features

  • Color ScopeMeter, 500 MHz, 4 channels
  • Two independent floating isolated inputs, up to 1000 V
  • Up to 5 GS/s real time sampling (Depending on model and channels used)
  • Deep memory: 10,000 points per trace waveform capture (scope mode)
  • CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments
  • Up to seven hours of battery operation using BP291
  • Isolated USB host port for direct data storage to a USB memory device; USB device port for easy PC communication
  • Easy access battery door for quick battery swaps in the field
  • Compact and only 2.2 kg (4.8 lb)
  • Security slot: lock down oscilloscope with Kensington® lock while unattended
  • IP 51 rating, dust- and drip-proof
  • Connect-and-View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals
  • Frequency Spectrum using FFT-analysis
  • Automatic capture and REPLAY of 100 screens
  • ScopeRecord™ Roll mode gives 30,000 points per input channel for low frequency signal analysis
  • TrendPlot™ paperless recorder mode with deep memory for long-term automatic measurements
  • 5,000 count DMM included in the 2-channel models
Loading Prices
Loading Callouts
Request a Quote
Loading Series Compare

Compare Products in this Series

Product Name Bandwidth Channels Sampling Rate Availability Price  
190-504/AM
190-504/AM
SCOPEMETER 4CH 500MHZ COLOR AMERICAS
500 Mhz 4 5 GS/S (5000 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-204/AM
190-204/AM
SCOPEMETER 4 CHANNEL 200 MHZ COLOR AMERICAS
200 Mhz 4 2.5 GS/S (2500 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-104/AM
190-104/AM
SCOPEMETER 4 CHANNEL 100 MHZ COLOR AMERICAS
100 Mhz 4 1.25 GS/S (1250 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-204/AM/S
190-204/AM/S
SCOPEMETER 4 CHANNEL 200 MHZ COLOR AMERI SCC
200 Mhz 4 2.5 GS/S (2500 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-202/AM/S
190-202/AM/S
SCOPEMETER 2CH 200MHZ COL AMERICAS SCC
200 Mhz 2 2.5 GS/S (2500 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-062/AM/S
190-062/AM/S
SCOPEMETER 2CH 60MHZ COL AMERICAS SCC
60 Mhz 2 625 MS/S Availability
in stock!
Edu Price Standard Price Gov't Price
190-102/AM/S
190-102/AM/S
SCOPEMETER 2CH 100MHZ COL AMERICAS SCC
100 Mhz 2 1.25 GS/S (1250 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-202/AM
190-202/AM
SCOPEMETER 2CH 200MHZ COL AMERICAS
200 Mhz 2 2.5 GS/S (2500 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-502/AM
190-502/AM
SCOPEMETER 2CH 500MHZ COL AMERICAS
500 Mhz 2 5 GS/S (5000 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-502/AM/S
190-502/AM/S
SCOPEMETER 2CH 500MHZ COL AMERICAS SCC
500 Mhz 2 5 GS/S (5000 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-104/AM/S
190-104/AM/S
SCOPEMETER 4 CHANNEL 100 MHZ COLOR AMERI SCC
100 Mhz 4 1.25 GS/S (1250 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-062/AM
190-062/AM
SCOPEMETER 2CH 60MHZ COL AMERICAS
60 Mhz 2 625 MS/S Availability
in stock!
Edu Price Standard Price Gov't Price
190-102/AM
190-102/AM
SCOPEMETER 2CH 100MHZ COL AMERICAS
100 Mhz 2 1.25 GS/S (1250 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price
190-504/AM/S
190-504/AM/S
SCOPEMETER 4CH 500MHZ COLOR AMERICAS SCC
500 Mhz 4 5 GS/S (5000 MS/S) Availability
in stock!
Edu Price Standard Price Gov't Price

Product Information

The four channel Fluke 190-504/AM is the top offering in the powerful 190 Series II line of color scopemeters. The 190-504/AM boasts a bandwidth of 500MHz, and a real-time sampling rate of 5 GS/s.  An easy to use combination of the power of a high performance oscilloscope, multimeter and paperless recorder, is what you get with the popular 190-504/AM. 

190 Series II ScopeMeter Oscilloscopes—the first highperformance scopes built for harsh industrial environments
Introducing the first high-performance portable oscilloscopes with 2 or 4 independently insulated input channels, an IP51 dust- and dripwater proof rating and a CAT III 1000 V/CAT IV 600 V safety rating. Choose from 500 MHz, 200 MHz, 100 MHz or 60 MHz bandwidth models. Now plant maintenance engineers can take a 2- or 4-channel scope into the harsh world of industrial electronics.

 

Fluke 190 Series II -- 20 years of ScopeMeter® Test Tool Innovation.
As the first two and four-channel portable scopes safety rated CAT III 1000V / CAT IV 600V, the Fluke ScopeMeter® 190 Series II combines an unprecedented level of performance, ruggedness, and portability. You can choose from 60MHz, 100MHz or 200MHz or 500MHz bandwidth models, with real-time sampling rates up to 5 GS/s and 200 ps resolution to capture noise and other disturbances. Both models feature deep memory—up to 10,000 samples per channel— so you can examine very small parts of the waveform in detail. And both are IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.

 


Gain Four Times the Diagnostic Power Plus CAT IV Safety Rating

The new Fluke ScopeMeter 190 Series II portable scopes are double-insulated two and four-channel floating oscilloscopes safety rated for measurements in CAT III 1000V/CAT IV 600V environments.

Three-dimensional testing for industrial systems »
Inspect input signals, output feedback loops or safety interlocks simultaneously to find a range of problems including:

  • Circuit voltage/current overloading
  • Signal timing measurements and synchronization issues
  • Attenuation/input impedance mismatch
  • Signal fluctuation/drif

Three-phase testing for diagnosing VSD, power inverters, and converters »

  • Test for harmonics, transients and loads at the three-phase power input
  • Troubleshoot dc to ac converters for faulty IGBT gates or filter circuits
  • Test PWM output for reflections and transients or voltage unbalance

Safely measure from mV to kV
Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.

Take on the Harshest Conditions with the only IP-51-rated Scope on the Market
Rugged and shock-proof, all ScopeMeter portable oscilloscopes are built for harsh environments. Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable accurate performance every time you need them.
Built in multimeter to quickly and conveniently perform precise measurements.
Built-in digital multimeter 190 Series II 2 channel models with isolated dual input scope and dedicated digital multimeter. Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors. The Fluke-190-X04, 4 channel models incorporate quad meter measurements via the 4 channel scope BNC inputs.
Work a Full Shift on a Single Charge
New high-performance batteries take advantage of Li-ion technology to keep you going strong for up to seven hours in 4 channel models or up to four hours in 2 channel models. And with the easy-access battery door you can make battery swaps fast.
Capture and Share Waveforms Easily with New USB connectivity
Two USB ports, electrically isolated from measurement input circuits offer you easy USB connectivity to a PC or USB memory devices. Store unlimited waveform, screen captures or instrument steups to a USB memory device. Connect to a PC USB interface to transfer and archive critical measurement data using FlukeView software for windows.
See a Stable Display Instantly with Connect-and-View™ Triggering
Connect-and-View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable, and repeatable display of virtually any signal including motor drive and control signals. Expedites measuring several test-points in rapid succession.
Record Up to 48 Hours of High-Resolution Waveforms with ScopeRecord™
ScopeRecord memory stores up to 30,000 data points per channel, capturing intermittents and fast glitches. (Two sets of multiple-channel recordings can be stored for later analysis.)
  • Stores events like motion profiles, UPS, power supply, and motor start-ups
  • With the Stop-on-Trigger mode, the ScopeMeter automatically recognizes a power failure and stores the waveform data preceding it
  • With the waveform zoom (up to 100x) you can look at the smallest details, like individual power cycles

What's In The Box

  • 4x VPS 410-x (one red, one blue, one grey, one green)
  • BC 190 Energy efficient Universal Power Supply 100-240V ±10%
  • BP 291 High capacity Li-ion battery pack (4800mAh)
  • Flukeview™ Software limited demo version  
  • Hanging strap and hand strap
  • Multi-language user manuals on CD-ROM
  • USB interface cable

Specifications

Fluke 190 Series 190-062 190-102 190-202 190-502 190-104 190-204 190-504
OSCILLOSCOPE MODES
Vertical deflection
Number of channels 2 2 2 2 4 4 4
Bandwidth 60 MHz 100 MHz 200 MHz 500 MHz 100 MHz 200 MHz 500 MHz
Rise time 5.8 ns 3.5 ns 1.7 ns 0.7 ns 3.5 ns 1.7 ns 0.7 ns
Number of scope inputs 2 input channels plus external trigger 4 input channels
Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination
Input coupling AC or DC, with ground level indicator
Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth
Normal/invert/variable On each input channel, switched separately
Input voltage CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
Vertical resolution 8 bit
Accuracy ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance 1 MΩ ± 1 % // 14 pF ± 2 pF
Horizontal
Maximum real-time sample rate (sampled simultaneously) 625 MS/s for each channel 1.25 GS/s for each channel 2.5 GS/s (2ch) 5 GS/s (single channel) or 2.5 GS/s (on 2ch) 1.25 GS/s for each channel 2.5 GS/s (2ch) 1.25 GS/s (4ch) 5 GS/s (single channel) or
1.25GS/s per channel
Record length Up to 10,000 samples per channel
Time base range
10 ns/div to 4 s/div 5 ns/div to 4 s/div 2 ns/div to 4 s/div 1 ns/div. to 4 s/div. 5 ns/div to 4 s/div 2 ns/div to 4 s/div 1 ns/div to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length 10,000 samples per channel in scope mode; 30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy ± (0.01 % of reading + 1 pixel)
Glitch capture 8 ns peak detect on each channel
(using real time sampling and data compression, at any timebase setting)
Display and Acquisition
Display 153 mm (6 in) full-color LCD with LED backlight
Display modes Any combination of channels; average on/off; replay
Visible screen width 12 divisions horizontally in scope mode
Digital persistence modes off/short/medium/long/infinite and envelope mode
Waveform mathematics One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode Frequency Spectrum using FFT analysis
Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and Delay
Source Input A, B or External (via meter input) Input A, B, C or D
Modes Automatic Connect-and-View™, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Video triggering (on ch. A) NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering (on channel A) Pulse width qualified by time
Allows for triggering t, =t, ? t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggering Triggers on both rising and falling edges alike
N-cycle triggering Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 9
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events
Replay Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storage Two sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window Automatic, Hamming, Hanning or None
Automatic window Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scale Linear/Logarithmic (in volts or amps)
Frequency axis Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform Compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope
Pass/Fail Testing In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), risetime (using cursors), falltime (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between any 2 inputs), pulsewidth (pos./neg.), dutycycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 I and 600 I, VPWM ac and VPWM(ac+dc) for measurement on pulsewidth modulated motordrives and frequency inverters, V/Hz ration (190-xx2 only)
Advanced power and motor drive functions V/Hz ratio (190-x02 only), Power Factor (PF), Watts, VA, VA reactive, VPWMac and VPWM (ac+dc) for measurement on pulsewidth modulated motordrives and frequency inverters
Advanced functions mA*s (current-over-time, between cursors);
V*s (voltage over time, between cursors);
W*s (energy, between cursors)
Cursor measurements
Source On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors
Single vertical line Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
ZOOM Ranges from full record overview to zoom in up to sample level, at any record length
METER MODES
Meter inputs Via 4 mm banana inputs, fully isolated from scope inputs and scope ground Via BNC scope inputs
Number of readings One at a time Up to 4 simultaneously
Maximum resolution 5,000 counts 999 counts
Input impedance 1 MO ± 1 % // 14 pF ± 2 pF
Advanced meter functions Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
  The specified accuracy is valid over the temperature range 18 °C to 28 °C
Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
V dc accuracy ± (0.5 % + 5 counts) ± (1.5 % + 5 counts)
V ac true rms accuracy
15 Hz to 60 Hz:
60 Hz to 1 kHz:
60 Hz to 20 kHz:
± (1 % + 10 counts)
± (2.5 % + 15 counts)
15 Hz to 60 Hz: ± (1.5 % + 10 counts) 60 Hz to 1 kHz:
60 Hz to 20 kHz: ± (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz:
60 Hz to 1 kHz:
60 Hz to 20 kHz:
± (1 % + 10 counts)
± (2.5 % + 15 counts)
15 Hz to 60 Hz: ± (1.5 % + 10 counts)
Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,000 V
Resistance
Ranges 500 O, 5 kO, 50 kO, 500 kO, 5 MO, 30 MO
Accuracy ± (0.6 % + 5 counts)
Other meter functions
Continuity Beeper on < 50 O (± 30 O)
Diode test Up to 2.8 V
Current (A) A dc, A ac, A ac+dc using an optional current clamp or shunt
Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
Temperature With optional accessories. Scale factors 1 °C/mV or 1 °F/mV
RECORDER MODES
ScopeRecord™ Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and display Input A, Input B, Dual.
All channels sampled simultaneously.
Any combination of inputs, up to 4 channels. All channels sampled simultaneously.
Bandwidth 20 MHz or 20 kHz, user selectable
Memory depth 30,000 data points, each holding min/max pair of information
Min/max values Min/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches
Recording modes Single sweep, continuous roll,
Start-on-Trigger (through external),
Stop-on-Trigger (through external)
Single sweep, continuous roll, Start-on-Trigger (through any channel), Stop-on-Trigger (through any channel)
Stop-on-trigger ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scale Time from start, time of day
Zoom Ranges from full record overview to zoom in up to sample level, at any record length
Memory Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range 5 ms/div ~ 2 min/div
Recorded timespan 6 sec ~ 48 hr
Time/division in ‘view all’ mode 0.5 s/div ~ 4 h/div
Glitch capture 8 ns
Sample rate 125 MS/s
Resolution 200 µsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and display Any combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth 18,000 points (sets) per measurement. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and timestamp.
Ranges Normal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time span Up to 22 days, with a resolution of 102 seconds
Recording mode Continuous recording, starting at 5 s/div with automatic record compression
Measurement speed 3 automatic measurements per second or more
Horizontal scale Time from start, time of day
Zoom Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Memory Two multiple input TrendPlot records can be saved internally for later recall and analysis Direct storage on external flash memory drive through USB host port
Cursor measurements—all recorder modes
Source Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical lines Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time.
GENERAL SPECIFICATIONS
Input voltage range
Rated maximum floating voltage CAT III 1000 V/CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410 CAT III 1000 V/CAT IV 600 V (Maximum voltage between 10:1 probe tip and reference lead)
Probe input voltage VPS510 CAT III 300 V (Maximum voltage between 10:1 probe tip and reference lead)
Maximum BNC input voltage CAT IV 300 V (maximum voltage on BNC input directly)
Maximum voltage on meter input CAT III 1000 V/CAT IV 600 V
(safety designed banana input connectors) —
Memory save and recall
Memory locations (internal) 30 waveform memories plus 10 recording memories plus 9 screen copy memories (190-XX, 2 channel models); 15 waveforms memories plus 2 recording memories plus 1 screen copy memory (190-XX, 4 channel models)
15 waveform memory locations Stores Scope-trace waveform data (2 or 4 traces each) plus screen-copy plus corresponding setup
Two recording memories Each may contain:
• a 100 Screen Replay sequence, or
• a ScopeRecord Roll-mode recording (2 or 4 traces), or
• a TrendPlot recording of up to 4 measurements
External data storage • On PC, using FlukeView™ Software, or
• Direct storage on external flash memory drive (maximum 2 GB) through USB host port
Screencopies • On PC, using FlukeView™ Software, or
• Internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
Volatility Measurement data is initially stored in RAM, which is maintained by the main battery with a 30 seconds back-up when battery is exchanged When storing data, this is written in non-volatile flash-ROM
Real-time clock Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings
Case
Design Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard Kensington lock supported to lock down instrument when left unattended
Drip and dust proof IP 51 according to IEC529
Shock and vibration Shock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2
Display size 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
Resolution 320 x 240 pixels
Contrast and brightness User adjustable, temperature compensated
Brightness 200 cd/m2 typ. using power adapter, 90 cd/m2 typical using battery power
Mechanical data
Size 265 mm x 190 mm x 70 mm (10.4 in x 7.5 in x 2.8 in)
Weight (including battery) 2.1 kg (4.6 lb) 2.2 kg (4.8 lb)
Power
Line power Mains adapter/battery charger BC190 included, version depending of country
Battery power Re-chargeable double capacity Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery] BP290; 2400 mAh
[BP291 (4800 mAh) optional]
BP291; 4800 mAh
Battery charge indicator Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen
Battery operating time (with backlight low) Up to four hours using BP290 (included), Up to eight hours using BP291 (optional) Up to seven hours using BP291 (included)
Battery charging time 2½ hours using BP290; 5 hours using BP291 Five hours BP291
Battery power saving functions Auto ‘power down’ with adjustable power down time; Auto ‘Display off’ with adjustable power down time; On-screen battery power indicator
Safety
Compliance EN61010-1-2001, Pollution Degree 2; CAN/CSA C22.2, No. 61010-1-04, with approval; UL61010B; ANSI/ISA-82.02.01
Environmental
Operating temperature 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature -20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95 % RH non-condensing;
+30 °C ~ +40 °C: 75 % RH non-condensing;
+40 °C ~ +50 °C: 45 % RH non-condensing
Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V;
up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic- Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry USB-host port directly connects to external flash memory drive (up to 2 GB) for storage of waveform data, complete datasets in which data and setup information is included, instrument settings and screen copies A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control
Probe calibration output Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel
Warranty Three years (parts and labor) on main instrument, one year on accessories
Included accessories
Battery charger/mains adapter BC190
Li-Ion battery pack BP290 (2400 mAh) BP291 (4800 mAh)
Voltage probe sets. Each set includes ground lead, hook clip, ground spring and probe tip insulation sleeve. VPS410 (one red, one blue) VPS410 (one red, one grey, one blue, one green)
Test leads TL175 (one red, one black) with test pins (N/A)
Voltage Probes VPS410-x: each set includes: Ground lead, hook clip, ground spring and probe tip insulation sleeve. VPS510-x: each set includes: Ground lead, hook clip, ground spring, probe tip insulation sleeve and BNC-to probe tip adapter.
Other Li-Ion battery (BP290 or BP291, see above); Battery charger (BC190); Hangstrap; Handstrip (user selectable for left- or right hand use); Multi language users manuals on CD-ROM; FlukeView® demo package (with restricted functionality); USB interface cable for PC connectivity.

Fluke 190-504/AM Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Multimeters Template

TypeDigital
StyleHand-Held
Measures AC VYes
Measures DC VYes
Measures AC ANo 
Measures DC ANo 
True RMS What's This?Yes
Maximum Voltage AC600 V 
Resolution AC Volts1 mV
Maximum Voltage DC600 V 
Resolution DC Volts1 mV
Basic Accuracy V DC1.5%
Counts What's This?999 .
BacklightYes
Manual/Autoranging What's This?Both
Dual DisplayNo
Analog Bargraph on DisplayNo
DecibelsYes
ResistanceYes 
FrequencyNo
Continuity What's This?Yes
CapacitanceNo
TemperatureNo 
Diode TestingYes
CAT Rating What's This?IV
CAT Voltage What's This?1,000 V, 300 V, 600 V 
Peak HoldNo 
Overload ProtectorNo
Kelvin 4-Wire Measurement Capability What's This?No
Intrinsically Safe What's This?No
Wireless DisplayNo
Data Hold What's This?No
Low-Pass Filter What's This?No
Duty Cycle %4% to 98%

Oscilloscopes/Portable Oscilloscopes Template

Bandwidth What's This?500 Mhz
Channels4
Sampling Rate What's This?5 GS/S (5000 MS/S)
Screen Type (Oscilloscopes)LCD
Isolated Inputs What's This?Yes
Screen Size6 IN
Bits What's This?8
Color ScreenYes
Rise Time What's This?0.7 ns

Test Equipment General Attributes

Unique FeaturesDual-input digital oscilloscope and multimeter.
Warranty3 YEARS
Warranty DetailsThree years (parts and labor) on main instrument, one year on accessories
Calibration IncludedNone
Power Supply Voltage120V/220V Universal, Battery Powered
Safety ApprovalCE, CSA
Data Logging What's This?Yes
Interfaces I/O USB Host, USB
StorageInternal Memory, USB Flash Drive
IP Rating What's This?IP51
Product Weight9.26 LBS
Battery TypeLi-ion 
Product Height4.72 IN
Product Length16.93 IN
Product Width16.93 IN
Shipping Weight10.19 LBS
Country of OriginRomania
Shipping Height4.72 IN
Shipping Length16.93 IN
Shipping Width16.93 IN
UPC095969601290

Reviews

Fluke 190-504/AM Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
 
Most Helpful First | Newest First      Prev Page
 
Prev Page
 

Accessories

Loading Accessories

Fluke Price List

Learn Before You Buy
Checkout Our Guides!

Instek MSO-2000E - Digital Oscilloscopes
Teledyne LeCroy WaveSurfer 510 1GHz digital oscilloscope
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X