Our agents are available:
9:00 AM - 6:00 PM EST
EZ Digital DM-341
Digital Multimeter
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



EZ Digital DM-341
Digital Multimeter




Click image to enlarge

  EZ Digital DM-341


Features:
  • 4 and 1/2 digit display, 19999 count
  • 0.05% basic accuracy on DC volts
  • Manual range type
  • AC/DC volts/amps
  • Resistance/Frequency/TR hfe/Capacitance/Diode/Continuity check
  • Low battery indication
  • Overload protection/Safety rubber holster



Model Description List Price Sale Price
DM-341 Handheld, Manual Ranging, TR, Hz, Diode, Cap. Cont. - Discontinued - no replacement

Click here to download DM-341 Series Operation Manual in PDF format
Click here to download the Calibration Manual in PDF format


   Specifications:

  Range Resolution Accuracy
DC Voltage 200mV
2V
20V
200V
0.01mV
0.1mV
1mV
10mV
±(0.1%+4dgt)
1000V 100mV ±(0.15%+4dgt)
AC Voltage 200mV
2V
20V
200V
750V
0.01mV
0.1mV
1mV
10mV
100mV
±(0.5%+10dgt)
DC Current 20mA
200mA
1μA
10μA
±(0.5%+1dgt)
10A 1mA ±(0.75%+3dgt)
AC Current 20mA
200mA
1μA
10μA
±(0.75%+10dgt)
10A 1mA ±(1.5%+10dgt)
Resistance 200Ω 0.01Ω ±(2.0%+5dgt)
2kΩ
20kΩ
200kΩ
0.1Ω

10Ω
±(2.0%+2dgt)
2MΩ
20MΩ
100Ω
1kΩ
±(0.5%+2dgt)
Capacitance 2000pF
200nF
0.1pF
1pF
±(2.0%+6dgt)
20μF 0.1nF ±(5.0%+6dgt)
Frequency 20kHz
200kHz
1Hz
10Hz
±(2.0%+3dgt)
TR hfe Base current 2.4μA and 3.0Vce
Diode Test approx. 3V test voltage / 1mA maximum test current
Continuity Test Yes
Accuracy is given as ±(% of reading number of least significant digits) at 18°C to 28°C with relative humidity up to 80% for a period of one year after calibration.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET