EZ Digital DM-334 Digital Multimeter
Specifications:
| |
Range |
Resolution |
Accuracy |
| DC Voltage |
400mV 4V |
0.1mV 1mV |
±(0.5%+1dgt) |
40V 400V |
10mV 100mV |
±(0.5%+3dgt) |
| 1000V |
1V |
±(0.7%+2dgt) |
| AC Voltage |
400mV 4V 40V 400V 750V |
0.1mV 1mV 10mV 100mV 1V |
±(1.0%+3dgt) |
| DC Current |
40mA 400mA |
10μ 0.1mA |
±(1.5%+2dgt) |
| 10A |
10mA |
±(2.0%+5dgt) |
| AC Current |
40mA 400mA |
10μ 0.1mA |
±(1.5%+3dgt) |
| 10A |
10mA |
±(2.0%+6dgt) |
| Resistance |
400Ω 4kΩ 40kΩ 400kΩ |
0.1Ω 1Ω 10Ω 100Ω |
±(0.7%+2dgt) |
| 4MΩ |
1kΩ |
±(1.0%+2dgt) |
| 40MΩ |
10kΩ |
±(2.5%+2dgt) |
| Frequency |
1Hz 1kHz 10kHz 100kHz 1MHz |
0.1Hz 1Hz 10Hz 100Hz 1kHz |
±(0.3%+3dgt) |
| Diode Test |
approx. 3V test voltage / 1mA maximum test current |
| Continuity Test |
Yes |
| Accuracy is given as ±(% of reading number of least significant digits) at 18°C to 28°C with relative humidity up to 80% for a period of one year after calibration. |
|