500 Amp Clamp-On CT
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Dent CT-CON-0500
500 Amp Clamp-On CT





Click image to enlarge
Dent CT-CON-0500-U

Features:
  • Nominal Rating: 500 Amps
  • Useful Current Range: 10 - 600 Amps
  • Window Diameter: 1.2"



  Description

Clamp-on current transformers are the one-hand operating solution for temporary or long-term studies. They are designed to work in tight places and clamp around bus bars.

DENT’s energy monitoring components are used for a variety of applications, including building automation, tenant submetering, performance verification, energy management and new technology assessment.




  Models, Options, & Accessories


Model Description List Price Sale Price
CT-CON-0500-U Current Transformer -- Clamp-On - Opening: 2" (50mm) Rectangular - Range: 10-600A - Terminations: Unterminated (For All Indoor Enclosures) $225.00
$213.75 
CT-CON-0500-B Current Transformer -- Clamp-On - Opening: 2" (50mm) Rectangular - Range: 10-1200A - Terminations: Banana Plug (Required for Weather-Tight Enclosures) $240.00
$228.00 



  Specifications

Electrical
Nominal Rating 500A
Useful Current Range 10 to 600A AC
Output Signal .666 mV/A
333mV @ 500A AC
Accuracy 10 to 600A: ± 2.5% ± .6A; 48-440 Hz
10 to 600A: ± 3.5% ± .6A; 440-1000Hz
Phase Shift 10 to 600A < 3°
Frequency Range 48 Hz to 1000 Hz
Mechanical
Dimensions 19.5 x 6.6 x 3.4 cm
(7.7 x 2.6 x 1.3”)
Maximum Cable/Bus Bar Cable Diameter 3.0 cm (1.2”)
Bus bar 6.3 x 0.5 cm (2.5” x 0.2”)
Polarity Red lead is positive
Output Lead Double insulated cable, 3 m (10 ft )
Operating Temperature -10° to 50°C (14° to 120°F)
Other
Jaw Opening 3.3 cm (1.2”)
Weight 350 g (12.3 oz)
Dielectric Strength 6000V, 50/60 Hz between primary, secondary and the outer case of the handle 3000V 50/60 Hz between primary and secondary
Storage Temperature -40° to +80° C (40° to 175° F)
Case Protection IP 40 (IEC 529)
Drop Test Test per IEC 68-2-32: 1.0 m drop on 38 mm of oak on concrete
Mechanical Shock Test per IEC 68-2-6
Common Mode Voltage 30 Vrms
Safety
Working Voltage Maximum 600 Vrms
CE Mark Extra insulation between electrical parts and handle; conforms to IEC 1010-2-032



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET