Compliance West HT-5000 AC/DC Hi-Pot Tester
Click image to enlarge
Compliance West HT-5000
|
Features:
- AC Output to 5000 volts; DC output to 7200 volts delivers up to 20 milliamps. Custom configurations up to 300 mA available..
- AC/DC selectable. Logic controlled, one button test. LED’s indicate test progress. Upon failure, buzzer sounds and testing is terminated.
- Leakage current limit, voltage ramp-up time and test duration are controlled from the rear panel. Output voltage adjustable from front and rear.
- Ground continuity test is defeatable for testing of two wire products.
- Automatic voltage rampdown circuit eliminates residual voltage.
- Voltage ramp, shutdown on failure and test timer are defeatable.
- 1 year warranty.
|
|
The HT-5000 is best suited for engineers conducting type testing and product design. Front panel voltage dial-up and AC/DC rocker switch make this unit easy to use. Test termination on failure, voltage ramp time, and the test timer may be disabled for specific research.
|
| Model |
Description |
List Price |
Sale Price |
| HT-5000 |
Hipot Tester, 0-5000Vac @ 10mA / 0-7000Vdc @ 5mA |
| $1595.00 |  |
|
| HT-5000-50mA |
Hipot Tester, 0-5000Vac @ 50mA / 0-7000Vdc @ 10mA |
| $2675.00 |  |
|
| HT-5000-50mA-I |
Hipot Tester, 0-5000Vac @ 50mA / 0-7000Vdc @ 10mA |
| $3695.00 |  |
|
| HT-5000AC-200mA |
Hipot Tester, 0-5000Vac @ 200mA |
| $4795.00 |  |
|
| HT-5000-200mA |
Hipot Tester, 0-5000Vac @ 200mA / 0-7000Vdc @ 200mA |
| $11895.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| TM |
TestMinder HT |
| $350.00 |  |
|
| 240 |
220/240V only operation |
| $145.00 |  |
|
| MT |
120/220-240V operation |
| $225.00 |  |
|
| RI |
Relay Isolated Remote Interface board |
| $350.00 |  |
|
| LC |
Leakage Current Display |
| $350.00 |  |
|
| VF |
Voltage Hold on Failure |
| $200.00 |  |
|
| MHC |
Manufactured Housing Cordset (2 red, 1 black) |
| $42.00 |  |
|
| MHC-RV |
Recreational Vehicle Cordset (2 red, 1 black, small alligator clips) |
| $40.00 |  |
|
Click here to download the HT-5000 Data Sheet in PDF format
Options:
Specifications:
|
Electrical
|
|
Output:
|
0-5000 Volts AC and 0-72000 Volts DC. Leakage current 0-10 mA AC; 0-5 mA DC Other configurations available.
|
|
Pass/Fail Criteria:
|
Leakage Current: Pass/Fail point user adjustable
Dielectric Breakdown: Separate high frequency detection circuit for breakdown spike detection.
|
|
Test Time:
|
User adjustable 1-60 sec.
|
|
Voltage Ramp Time:
|
User adjustable .5-5 sec.
|
|
Voltage Ramp Down Time:
|
Factory set 8 sec. maximum
|
|
Pass/Fail Repeatability:
|
± 3%
|
|
Duty Cycle:
|
100%
|
|
Meter Accuracy:
|
±3% Full Scale
|
|
Test Adjustments:
|
Rear panel: Ramp Time / Test Time / Leakage Limit / Voltage Adjust / Voltage Ramp Defeat / Timer Duration Defeat / Shutdown on Faliure Defeat.
|
|
Environmental
|
|
Operating Temperature:
|
15-40°C
|
|
Relative Humidity Range:
|
0-90% non-condensing
|
|
General
|
|
Input Power Requirements:
|
114-127 volts, 50/60 Hz
|
|
Weight:
|
17.5 lbs.
|
|
Dimensions:
|
11.250 (W) x 4.250 (H) x 12.000 (L) in.
|
|
Safety
|
|
Transformer Output:
|
<500 VA
|
|
Visual Indication Of Voltage Output:
|
Provided by front panel meter, directly connected to high voltage output.
|
|
Failure Indication:
|
Audible, provided by internal buzzer. Visual, provided by red LED’s on front panel. Test automatically terminated on failure.
|
|
Leakage Test:
|
Provided; 5mA factory set pass/fail point, user adjustable. 120 KΩ calibration resistor provided on rear panel.
|
|