Compliance West HT-3000 AC/DC Hi-Pot Tester
Click image to enlarge
|
Features:
- AC Output to 2000 volts; delivers up to 20mA, and DC output to 2800 volts; delivers up to 5mA.
- Logic controlled, one button test. LEDs indicate test progress. Upon failure, buzzer sounds and testing is terminated.
- Output voltage, leakage current limit, voltage ramp-up time and test duration are controlled from the rear panel.
- Ground continuity test is defeatable for testing of two wire products.
- Two high voltage output connections; NEMA 5-15R receptacle and a high voltage test jack.
- Automatic voltage rampdown circuit eliminates residual voltage.
- Performs to UL, CE, IEC, CSA, TUV safety agency requirements for production line testing.
- 1 year warranty.
|
| The HT-3000 is suitable for component testing as well as testing of finished products. This unit contains all the features of both the HT-2000 and HT-2800 with an AC/DC rocker switch on front panel. This unit performs the production line tests required by UL, CSA and CE. Provided with leads, manual and calibration certificate. |
| Model |
Description |
List Price |
Sale Price |
| HT-3000 |
Hipot Tester, 0-2000Vac @ 20mA/ 0-2800Vdc @ 5mA |
| $1495.00 |  |
|
| HT-3000AC-1A |
Hipot Tester, 0-3000Vac @ 1A |
| $5795.00 |  |
|
| HT-3000DC-500mA |
Hipot Tester, 0-3000Vac output @ 500mA |
| $5495.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| TM |
TestMinder HT |
| $350.00 |  |
|
| TL |
TestLink for GF and HT test combination |
| $100.00 |  |
|
| 240 |
220/240V only operation |
| $145.00 |  |
|
| MT |
120/220-240V operation |
| $225.00 |  |
|
| AR |
Auto Reset on Pass |
| $100.00 |  |
|
| RI |
Relay Isolated Remote Interface board |
| $350.00 |  |
|
| LC |
Leakage Current Display |
| $350.00 |  |
|
| LI |
Line Current Measurement |
| $350.00 |  |
|
| LR |
Line Resistance Measurement |
| Call |  |
|
| AH |
2500Vac 20mA and/or 3400Vdc 5mA output |
| $145.00 |  |
|
| DH |
3500Vdc 5mA output |
| $145.00 |  |
|
| LLC |
Low Leakage Current Trip (10uA min) |
| $100.00 |  |
|
| VF |
Voltage Hold on Failure |
| $200.00 |  |
|
| XI |
External Interlock |
| $360.00 |  |
|
| HVP |
High Voltage Probe (up to 10kV) |
| $150.00 |  |
|
| SV |
Safe Voltage Relay Output |
| $200.00 |  |
|
| MHC |
Manufactured Housing Cordset (2 red, 1 black) |
| $42.00 |  |
|
| MHC-RV |
Recreational Vehicle Cordset (2 red, 1 black, small alligator clips) |
| $40.00 |  |
|
Click here to download the HT-3000 Data Sheet in PDF format
| Electrical |
| Output: |
0-2000 Volts AC and 0-2800 Volts DC. Pigtail and Receptacle adapters available for most configurations. Consult factory. |
| Leakage Current: |
0-20 mA AC; 0-5 mA DC |
| Pass/Fail Criteria: |
Ground Continuity: 3Ω ±5% * (defeatable)
Leakage Current: Pass/Fail point user adjustable.
Dielectric Breakdown: Separate high frequency detection circuit for breakdown spike detection. |
| Test Time: |
User adjustable 1-60 sec. |
| Voltage Ramp Time: |
User adjustable .5-5 sec. |
| Voltage Ramp Down Time: |
Factory set 1 sec. approx. |
| Pass/Fail Repeatability: |
± 3% |
| Duty Cycle: |
100% |
| Meter Accuracy: |
±3% Full Scale |
| Test Adjustments: |
Rear Panel: Ramp Time, Test Time, Leakage Limit, Voltage Adjust. Tamper-proof operation available by removing adjustment shafts. |
| Environmental |
| Operating Temperature: |
15-40°C |
| Relative Humidity Range: |
0-90% non-condensing |
| General |
| Input Power Requirements: |
114-127 volts, 50/60 Hz |
| Weight: |
10.5 lbs. |
| Dimensions: |
9.250 (W) x 4.250 (H) x 10.000 (L) in. |
| Safety |
| Transformer Output: |
<500 VA |
| Visual Indication Of Voltage Output: |
Provided by front panel meter, directly connected to high voltage output. |
| Failure Indication: |
Audible, provided by internal buzzer. Visual, provided by red LEDs on front panel. Test automatically terminated on failure. |
| Ground Test: |
Provided; 3 ohm pass/fail point. May be defeated for testing of products with two wire power supply cords. |
| Leakage Test: |
Provided; 5mA AC/1 mA DC factory set pass/fail point, user adjustable. 120 KΩ calibration resistor provided on rear panel. |
| Operation Instructions: |
Provided on rear panel. |
|