Our agents are available:
9:00 AM - 6:00 PM EST
Compliance West
HT-20000AC AC Hi-Pot Tester
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Compliance West
HT-20000AC AC Hi-Pot Tester



Compliance West HT-20000AC Click image to enlarge

  Compliance West
  HT-20000AC
Features:
  • AC output to 20Kv. Delivers up to 10 mA leakage current. Custom outputs available to 25mA.
  • Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
  • Rear panel adjustments: leakage limit, ramp time, test time and voltage.
  • Automatic voltage ramp-down circuit eliminates residual voltage.
  • Designed for product development and laboratory use.
  • High voltage test jack output.
  • Calibrated to NIST standards.
  • 1 year warranty
The HT-20000 is available for very high voltage dielectric withstand testing, in either an AC Voltage or DC Voltage output design. The front panel voltage dial-up makes this unit easy to use. As with our HT-5000, test termination on failure, voltage ramp time, and the test timer may be disabled for specific research. Provided with leads, manual, and calibration certificate.



Model Description List Price Sale Price
HT-20kVac Hipot Tester, 0-20kV @ 8mA to 15kV, derated 1.2mA/kv above - Discontinued - no replacement
HT-20kVac-25mA Hipot Tester, 0-20kV @ 25mA - Discontinued - no replacement
Model Accessories List Price Sale Price
VF Voltage Hold on Failure
$200.00 
240 220/240V only operation
$145.00 
MT 120/220-240V operation
$225.00 
RI Relay Isolated Remote Interface board
$350.00 
MHC Manufactured Housing Cordset (2 red, 1 black)
$42.00 
MHC-RV Recreational Vehicle Cordset (2 red, 1 black, small alligator clips)
$40.00 

    Options:


    Specifications:

Electrical
Output: 0-20000 Volts AC, Leakage Current: 0-8 mA to 15 kVAC, derated 1.2 ma/kV to 20 kVAC
Pass/Fail Criteria: Leakage Current: Pass/Fail point user adjustable.
Dielectric Breakdown: Separate high frequency detection circuit for breakdown spike detection
Test Time: User adjustable 1-60 sec., defeatable.
Voltage Ramp Up Time: User adjustable 1-5 sec., defeatable
Voltage Ramp Down Time: Factory set 8 sec. maximum
Pass/Fail Repeatability: ± 3%
Duty Cycle: 100%
Test Adjustments: Front panel: Ramp Time, Test Time, Leakage Limit, Voltage Adjust, Voltage Ramp ON/DEFEAT, Timer Duration ON/DEFEAT, Failure Shutdown ON/DEFEAT


Environmental
Operating Temperature: 15-40°
Relative Humidity Range: 0-90%, non-condensing


General
Input power requirements: 114-127 volts, 50/60 Hz
Weight: 32 lbs.
RESET and TEST Lamp Type: Replace with type 73 14V lamp.


Safety Agency Topics
Transformer Output: < 500VA
Visual Indication of Voltage Output Provided by front panel meter, directly connected to high voltage output
Failure Indication: Audible, provided by internal buzzer
Visual, provided by red LEDs on front panel
Test can be automatically terminated on failure
Leakage Test: Provided; 5 mA AC factory set pass/fail point, user adjustable.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET