HT-2000 AC Hi-Pot Tester
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Compliance West
HT-2000 AC Hi-Pot Tester



Compliance West HT-2000 Click image to enlarge

  Compliance West
  HT-2000

Features:
  • AC Output to 2000 volts; delivers up to 20mA.
  • Logic controlled, one button test. LED’s indicate test progress. Upon failure, buzzer sounds and testing is terminated.
  • Output voltage, leakage current limit, voltage ramp-up time and test duration are controlled from the rear panel.
  • Ground continuity test is defeatable for testing of two wire products.
  • Nema 5-15R receptacle provided on front panel for high voltage output.
  • Automatic voltage rampdown circuit eliminates residual voltage.
  • Performs to UL, CE, IEC, CSA, TUV safety agency requirements for production line testing.
  • 1 year warranty.
The HT-2000 is ideal for general purpose production-line testing of electrical, medical and other low primary-to-ground capacitance products. This unit performs all the production line tests required by UL CSA and CE. Provided with leads, manual and calibration certificate.



Model Description List Price Sale Price
HT-2000 Hipot Tester, 0-2000Vac @ 20mA
$995.00 
Model Accessories List Price Sale Price
TM TestMinder HT
$350.00 
TL TestLink for GF and HT test combination
$100.00 
240 220/240V only operation
$145.00 
MT 120/220-240V operation
$225.00 
AR Auto Reset on Pass
$100.00 
RI Relay Isolated Remote Interface board
$350.00 
LC Leakage Current Display
$350.00 
LI Line Current Measurement
$350.00 
LR Line Resistance Measurement
Call
AH 2500Vac 20mA and/or 3400Vdc 5mA output
$145.00 
LLC Low Leakage Current Trip (10uA min)
$100.00 
HO Front Panel High Voltage Receptacle and Lead
$50.00 
MHC Manufactured Housing Cordset (2 red, 1 black)
$42.00 
MHC-RV Recreational Vehicle Cordset (2 red, 1 black, small alligator clips)
$40.00 

Click here to download the HT-2000 Data Sheet in PDF format


    Options:



    Specifications:


Electrical
Output: 0-2000 Volts AC into NEMA 5-15R recptacle. Pigtail and Receptacle adapters available for most configurations. Consult factory.
Leakage Current: 0-20 mA
Pass/Fail Criteria: Ground Continuity: 3Ω ±5% * (defeatable)
Leakage Current: User adjustable 1-20 mA
Dielectric Breakdown: Separate high frequency detection circuit for breakdown spike detection.
Test Time: User adjustable 1-60 sec.
Voltage Ramp Time: User adjustable .5-5 sec.
Pass/Fail Repeatability: ± 3%
Duty Cycle: 100%
Meter Accuracy: ±3% Full Scale
Discharge Time: Voltage dependent; discharge progress displayed on front panel meter.
Test Adjustments: Tamper-proof operation available.


Environmental
Operating Temperature: 15-40°C
Relative Humidity Range: 0-90% non-condensing


General
Input Power Requirements: Model HT-2000: 114-127 volts, 50/60 Hz
Model HT-2000L: 98-109 volts, 50/60 Hz
Weight: 10.5 lbs.
Dimensions: 9.250 (W) x 4.250 (H) x 10.000 (L) in.


Safety
Transformer Output: <500 VA
Visual Indication Of Voltage Output: Provided by front panel meter, directly connected to high voltage output.
Failure Indication: Audible, provided by internal buzzer. Visual, provided by red LED’s on front panel. Test automatically terminated on failure.
Ground Test: Provided; 3 ohm pass/fail point. May be defeated for testing of products with two wire power supply cords.
Leakage Test: Provided; 5mA factory set pass/fail point, user adjustable. 120 Kohm calibration resistor provided on rear panel.
Operation Instructions: Provided on rear panel.




   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET