company logo Compliance West
HT-2000 AC Hi-Pot Tester
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 




Compliance West
HT-2000 AC Hi-Pot Tester



Compliance HT-2000
Click image to enlarge

 Compliance HT-2000

Features:
  • AC Output to 2000 volts; delivers up to 20mA.
  • Logic controlled, one button test. LED’s indicate test progress. Upon failure, buzzer sounds and testing is terminated.
  • Output voltage, leakage current limit, voltage ramp-up time and test duration are controlled from the rear panel.
  • Automatic voltage rampdown circuit eliminates residual voltage.
  • Ground continuity test is defeatable for testing of two wire products.
  • Nema 5-15R receptacle provided on front panel for high voltage output.
  • Performs to UL, CE, IEC, CSA, TUV safety agency requirements for production line testing.
  • 1 year warranty.
Options:



  Description

The HT-2000 is ideal for general purpose production-line testing of electrical, medical and other low primary-to-ground capacitance products. This unit performs all the production line tests required by UL CSA and CE. Provided with leads, manual and calibration certificate.

The most user-friendly hipot/continuity tester on the market today, at an attractive price. Watch to see how easy it is to operate!

Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.

Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel.

Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.

Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate included.

In-depth testing. Both Arc Dectection and Leakage Current circuits test the product for more accurate testing.

RED lights and a buzzer leave no question if a failure has occurred.

Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™.

Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1.




  Models, Options, & Accessories


Model Description List Price Sale Price
HT-2000 Hipot Tester, 0-2000Vac @ 20mA - Discontinued - replaced by Compliance HT-2000P
HT-2000P Hipot Tester, P controlled, 0-2000Vac @ 20mA
$1095.00 
Model Accessories List Price Sale Price
TM TestMinder HT
$350.00 
TL TestLink for GF and HT test combination
$100.00 
240 240V only operation
$200.00 
HVP High Voltage Probe (up to 10kV)
$150.00 
MT 120/220-240V operation - Discontinued - no replacement
AR Auto Reset on Pass
$100.00 
RI Relay Isolated Remote Interface board
$350.00 
LC Leakage Current Display - Discontinued - no replacement
LI Line Current Measurement - Discontinued - no replacement
LR Line Resistance Measurement
Call
AH 2500Vac 20mA and/or 3400Vdc 5mA output
$145.00 
LLC Low Leakage Current Trip (10uA min) - Discontinued - no replacement
HO Front Panel High Voltage Receptacle and Lead
$50.00 
MHC Manufactured Housing Cordset (2 red, 1 black)
$40.00 
MHC-RV Recreational Vehicle Cordset (2 red, 1 black, small alligator clips)
$40.00 



  Specifications

Electrical
Output 0-2000 Volts AC into NEMA 5-15R recptacle. Pigtail and Receptacle adapters available for most configurations. Consult factory.
Leakage Current 0-20 mA
Pass/Fail Criteria Ground Continuity: 3Ω ±5% * (defeatable)
Leakage Current: User adjustable 1-20 mA
Dielectric Breakdown: Separate high frequency detection circuit for breakdown spike detection.
Test Time User adjustable 1-60 sec.
Voltage Ramp Time User adjustable .5-5 sec.
Pass/Fail Repeatability ± 3%
Duty Cycle 100%
Meter Accuracy ±3% Full Scale
Discharge Time Voltage dependent; discharge progress displayed on front panel meter.
Test Adjustments Tamper-proof operation available.

Environmental
Operating Temperature 15-40°C
Relative Humidity Range 0-90% non-condensing

General
Input Power Requirements Model HT-2000: 114-127 volts, 50/60 Hz
Model HT-2000L: 98-109 volts, 50/60 Hz
Weight 10.5 lbs.
Dimensions 9.250 (W) x 4.250 (H) x 10.000 (L) in.

Safety
Transformer Output <500 VA
Visual Indication Of Voltage Output Provided by front panel meter, directly connected to high voltage output.
Failure Indication Audible, provided by internal buzzer. Visual, provided by red LED’s on front panel. Test automatically terminated on failure.
Ground Test Provided; 3 ohm pass/fail point. May be defeated for testing of products with two wire power supply cords.
Leakage Test Provided; 5mA factory set pass/fail point, user adjustable. 120 Kohm calibration resistor provided on rear panel.
Operation Instructions Provided on rear panel.




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.