Compliance West 10x360s-1-2 MegaPulse Impulse Tester
Click image to enlarge
Compliance West 10x360s-1-2
|
Features:
- Generates the waveforms required by GR-1089, Issue 1, 2 or 3 in accordance with the referenced Table or Paragraph.
- Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse within the 968 Series, allowing easy sanity checks and proof to visiting agency engineers of test setups.
- 1000:1 BNC Oscilloscope output allows quick connections and easy evaluation of output waveforms.
- Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors.
- Additional outputs for four-wire testing, as needed, up to four. Can be expanded to 24 channels; consult factory.
- 1 year warranty
|
Peak output voltage is 1000 volts minimum, peak short circuit current is 100A minimum. A switch is provided for reversal of output polarity. Optional divider network available for oscilloscope connection.
Waveform generated is 10x360/10/360, Vp= 1000V. To perform the Surge 2 test, the front panel voltage meter is set to 1000V and the 10Ω tap is used. To perform the Surge 5 test, the front panel voltage meter is set to 1000V and the 40Ω tap is used.
Two output taps are provided, one with Zout=10Ω and one with Zout=40Ω.
Enclosure is 19 x 3U, rack mountable (not as shown).
Outputs are isolated.
The MegaPulse 10x360s-1 ships with cables, graphs of theoretical and actual waveforms, and a Calibration Certificate. One year warranty. Options include relay outputs for PLC control, and two 1000:1 oscilloscope BNC jacks (differential mode only).
This tester is configured with two outputs for testing two-wire products in accordance with Table 4-1 Test Condition A and B.
|
| Model |
Description |
List Price |
Sale Price |
| 10x360s-1-2 |
1000V peak symmetrical voltage and current output, two ch. |
| $5875.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| MT |
120/220-240V operation |
| $225.00 |  |
|
| BNCV |
Voltage BNC for MegaPulse option (grounded output testers only) |
| $200.00 |  |
|
| BNCI |
Current BNC MegaPulse option |
| $200.00 |  |
|
| RI |
Relay Isolated Remote Interface board |
| $350.00 |  |
|
| FC |
Fast Charge Power Supply (contact factory) |
| $430.00 |  |
|
| TMM |
TestMinder MegaPulse w/repetitive pulse capability |
| $1250.00 |  |
|
| IFD |
MegaPulse Insulation Fault Detector, Adjustable trip |
| $860.00 |  |
|
Options:
Specifications:
|
Specifications
|
|
Voltage Rise Time:
|
10 μs
|
|
Voltage Duration:
|
360 μs |
|
Current Rise Time:
|
10 μs
|
|
Current Duration:
|
360 μs
|
|
Max Voltage:
|
1000V
|
|
Meter Accuracy:
|
±120V
Better than 1% of full-scale reading
|
|
Operating Temperature:
|
15-40°C
|
|
Relative Humidity Range:
|
0-90% Non-Condensing
|
|
Input Power Requirements:
|
120 V AC, 50/60 Hz, 1 Amp
230 V optional; check with factory
|
|
Dimensions:
|
11.250 (W) x 12.000 (D) x 5.000 (H) in.
|
|
Weight:
|
16 lbs.
|
|