Compliance West 1.2x50-7 MegaPulse Impulse Tester

Click image to enlarge
Compliance West 1.2x50-7
|
Features:
- Generates either of the waveforms described in EN60950, Annex N, Table N.1, for testing electrical separation (MegaPulse 10/700 Series) or creepage in floating secondary circuits (MegaPulse 1/2/50 Series). Use a general purpose oscilloscope to read and record test results.
- Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse, allowing easy sanity checks and proof to visiting agency engineers of test setups.
- 1000:1 BNC Oscilloscope output option allows quick connections and easy evaluation of output waveforms.
- Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors.
- 1 year warranty
|
The 1.2/50-7 is designed to test the clearances in floating secondary circuits as described in Para. 2.9.1. The waveform generated is in accordance with the instructions in Annex N, Table N.1, line 2. In accordance with these requirements, the 1.2/50-7 can generate the required waveform with up to 7,000 volts peak A front panel switch reverses output polarity. Use with a general purpose oscilloscope for waveform capture.
The MegaPulse 1.2/50-7 ships with cables, graphs of theoretical and actual waveforms, and a Calibration Certificate. One year warranty. Options include relay outputs for PLC control, and a 1000:1 oscilloscope output BNC jack.
|
| Model |
Description |
List Price |
Sale Price |
| 1.2x50-7 |
2000-7000V, 1.2x50-7 Voltage Waveform, 39 ohm 1 chnl |
| $3495.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| IER |
IEC 65 Figure 7b Switch |
| $1650.00 |  |
|
| IFD |
MegaPulse Insulation Fault Detector, Adjustable trip |
| $860.00 |  |
|
Options:
Specifications:
|
Specifications
|
|
Voltage Rise Time:
|
1.2 μs
|
|
Voltage Duration:
|
50 μs |
|
Current Rise Time:
|
8 μs
|
|
Current Duration:
|
20 μs
|
|
Max Voltage:
|
7000V
|
|
Meter Accuracy:
|
±140V
Better than 1% of full-scale reading
|
|
Operating Temperature:
|
15-40°C
|
|
Relative Humidity Range:
|
0-90% Non-Condensing
|
|
Input Power Requirements:
|
120 V AC, 50/60 Hz, 1 Amp
230 V optional; check with factory
|
|
Dimensions:
|
11.250 (W) x 12.000 (D) x 5.000 (H) in.
|
|
Weight:
|
16 lbs.
|
|