Bacharach 55-8020 Hi Flow Sampler Natural Gas Leak Rate Measurement Bacharach 55-8020, 55 8020, 558020
Our agents are available:
9:00 AM - 6:00 PM EST
Bacharach 55-8020 Hi Flow Sampler
Natural Gas Leak Rate Measurement
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Bacharach 55-8020 Hi Flow Sampler
Natural Gas Leak Rate Measurement




Click image to enlarge

 55-8020

Datasheet
User Manual

Features:
  • Allows ranking of gas leaks in leak-rate order
  • Re-chargeable, NiMH battery pack
  • Allows users to determine payback periods for particularly expensive repairs
  • Allows users to determine the potential savings from repairing a leak by calculating cost of lost gas
  • Allows more cost-effective use of your maintenance budget
  • Identifies problem areas
  • Determines baseline leakage conditions
  • Provides permanent record of leakage and repair
  • Greenhouse gas credits
  • Pays for itself in recovered gas
  • Intrinsically safe for Hazardous Locations, Class 1, Div. 1 Groups A, B, C, and D
  • One-man operation


Includes:
  • Backpack
  • Sampling hose assembly
  • (2) rechargeable battery packs
  • Battery charger
  • Sampling attachments including flange attachments, beveled attachments and capture bags



  Description

Hi Flow Sampler Natural Gas Leak Rate Measurement

The Hi Flow Sampler is designed to measure the rate of gas leakage around various pipe fittings, valve packings, and compressor seals found in natural gas transmission, storage, and compressor facilities. This is accomplished by sampling at a very large flow rate (8 to 10 SCFM) to completely capture any gas leaking from the component. Then by accurately measuring the flow rate of the sampling stream and the natural gas concentration, it is possible to calculate the rate of the gas leak.

Taking Leak Detection To A New Dimension

Many changes and enhancements have been made from the original instrument including: intrinsic safety; data logging, and instantaneous leak-rate display just to name a few.




  Models, Options, & Accessories


Model Description List Price Sale Price
55-8020 Please call or email us for pricing and availability.
Model Accessories List Price Sale Price
55-8002 Please call or email us for pricing and availability.
55-0060 Please call or email us for pricing and availability.
51-1121 Calibration gas, 2.5% CH4, 103 L $155.00
$147.25 
55-0270 Please call or email us for pricing and availability.
55-8000 Please call or email us for pricing and availability.



  Specifications

Measured Values Gas sample flow rate
Background gas concentration
Sample gas concentration
Calculated Values Leak rate of component under test
Leak concentration corrected for background
Measurable Leak Rate 0.05 to 8.00 SCFM
Accuracy of Calculated Leak Rate ±10%
Sampling Flow Rate 10.5 SCFM maximum (297 LPM) at full battery charge
Memory Stores up to 1000 individual test parameters
Natural Gas Sensor Detection Method: Catalytic oxidation / Thermal conductivity
Range: 0 to 5% methane, catalytic; 5 to 100% methane, thermal
Hi Flow Sampler Natural Gas Leak Rate Measurement
Battery Type: NiMH rechargeable pack
Voltate: 5.5V max.
Recharge Time: 8 to 10 hours
Run Time: >4.5 hours continuous at 68°F
Operating Temperature 32 to 122°F
Measurement Method Differential pressure across restriction
Dimensions 18 x 12 x 7 inches
Weight 20 lb
Agency Approvals Designed to be intrinsically safe for use in hazardous locations, Class I, Division 1, Groups A, B, C & D in North America
CAN/CSA-C22.2 No. 157 (June 1992)
ANSI (June 27, 2002)/UL913-2002
CE Mark

    back to top



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET