Bacharach 19-8038 Informant 2 Dual Purpose Refrigerant & Combustible Gas Leak Detector
|
|
Features:
- One instrument-two functions
- Lightweight and ergonomically designed
- Swap sensor tips in seconds
- Microprocessor controlled for accuracy and reliability
- Sensitivity is automatically adjusted
- Sensors are the industry’s most responsive
- Hydrophobic filter prevents moisture contamination
- Optional rubber boot holds MagLite flashlight
- Sequential flashing probe tip, dual LED displays and loud tick rate indicates relative concentration levels
- Detects all halogens and combustibles
- Response time is two-tenths of one second
- Probe length adjustable from 3" to 20"
|
Description
|
Dual Purpose Refrigerant & Combustible Gas Leak Detector
The Informant2 leak detector allows pinpoint detection of both refrigerant and combustible gas leaks with the same instrument.
Its unique combination of state-of-the-art patented sensor technology, advanced software design and microprocessor controlled circuitry offers you unmatched precision coupled with tremendous speed. It is unquestionably the most sensitive, most reliable, most accurate leak detector on the market today. And the fastest.
Swap sensor tips within seconds and never worry about adjusting sensitivity levels-it’s taken care of automatically-even where high levels of background vapors or refrigerants are present. The refrigerant sensor tip is finely tapered to 0.2 inch diameter-so you can get in between coils and fittings, gaining access to hard to reach areas.
The Informant2 leak detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of refrigerant or combustible gases.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 19-8038 |
Informant 2 Contractor Kit Instrument comes with refrigerant and combustible gas sensors, color-coded probe tips, instruction manual, 4 AA batteries and a hard carrying case. |
$411.00 |
| $390.45 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| 19-8042 |
Dual refrigerant/combustible gas Informant 2 detector kit with refrigerant and combustible gas sensors, color-coded probe tips, instruction manual, 4 AA batteries, 5 filters and a soft carrying case. |
$440.00 |
| $418.00 |  |
|
| 19-8045 |
Deluxe dual refrigerant/combustible gas Informant 2 detector kit with refrigerant and combustible gas sensors, color-coded probe tips, protective rubber boot, flashlight, instruction manual, 6 AA batteries, 5 filters and a hard carrying case. |
$521.00 |
| $494.95 |  |
|
| 19-8040 |
Refrigerant only Informant 2 detector kit with refrigerant sensor, color-coded probe tip, instruction manual, 4 AA batteries, 5 filters and a soft carrying case. |
$370.00 |
| $351.50 |  |
|
| 19-8037 |
Deluxe upgrade kit. Includes protective rubber boot, MagLite, 2 AA batteries and a hard carrying case. |
$109.00 |
| $103.55 |  |
|
| 19-8047 |
Combustible gas upgrade kit, to upgrade a refrigerant Informant 2 to a dual sensing instrument. Includes a combustible gas sensor, color coded probe tip and 5 filters. |
$88.00 |
| $83.60 |  |
|
| 19-0499 |
Replacement combustible gas sensor (Informant 2 only) |
$42.00 |
| $39.90 |  |
|
| 19-0510 |
Replacement refrigerant sensor (Informant and Informant 2) |
$42.00 |
| $39.90 |  |
|
| 19-0509 |
Replacement filters, pack of five (Informant and Informant 2) |
$9.00 |
| $8.55 |  |
|
Specifications
| Sensing Elements |
Refrigerant - Heated Diode, U.S. Patent No. 5,932,176 Combustible - Patented semiconductor type, 5 year typical life, plug-in replacement |
| Refrigerants Detected |
All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or Bromine gas) |
| Combustible Gases Detected |
All combustible gases and vapors |
| Alarm Sensitivity |
Refrigerant 0.25 oz/year of R134a (hardest to detect refrigerant) Combustibles Minimum 50 PPM (Methane) |
| Alarm Types |
Audible and dual visual LEDs |
| Power Source |
Four (4) AA disposable alkaline batteries included |
| Warm-up Time |
10 seconds |
| Response Time |
0.2 second |
| Battery Life |
4 to 5 hours, under typical intermittent operation. |
| Probe |
20" (50.8 cm) maximum length, fully extended; 3" (7.62 cm) if wrapped around instrument. Includes LED indicator |
| Size |
1.75"W (4.44cm) x 9.62"L (24.43cm) x 2.25"H (5.72 cm) |
| Weight |
0.86 lbs. (0.39 kg) with batteries |
| Agency Approvals |
Refrigerant UL listed in accordance with SAE J1627 Combustible MET Lab certified to UL 913, intrinsically safe for use in Class I, Division 1, Group D hazardous areas. |
| CE-Mark |
Independently tested |
|