company logo BK 878A Dual Display Auto Ranging LCR Meter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 

 
 




BK 878A Dual Display Auto Ranging LCR Meter



BK 878A
Click image to enlarge

 BK 878A

Features:
  • Selectable test frequencies 120Hz, 1KHz
  • Simultaneously displays measured component value and Q or Dissipation Factor (D)
  • Display hold
  • Relative mode
  • Tolerance mode
  • RS 232 Interface (cable and software required)



  Description

The 878A measures capacitance, resistance (of non-inductive components) and inductance. Components can be measured with selectable test frequencies in series or parallel modes as desired. The 4 1/2 digit main LCD displays values to 19,999, and the secondary 3 digit 1,000 count display reads D or Q. Both models can be used in either auto ranging or manual ranging modes.




  Models, Options, & Accessories


Model Description List Price Sale Price
878A Universal LCR Meter
$249.00 
Model Accessories List Price Sale Price
AK 87X Software and RS-232 cable for 878A and 879
$78.00 
LC 29B DMM Carrying Case
$17.75 
TL 8 Tweezer Test Lead (Surface Mount)
$26.00 
TL LCR Test Leads for 875B, 878, 878A, 879, 890, & 890B (Sheathed)
$10.00 



  Specifications

Parameters Measured L/C/R/D/Q
Measuring Circuit Mode Inductance (L)
–Defaults to series mode
Capacitance/ Resistance (C/R)
-Defaults to parallel mode
Displays L/C/R: Maximum display 19999
D/Q: Maximum display 999 (Auto Range)
Ranging Mode Auto & Manual
Measuring Terminals 3 terminals with sockets
Test Frequency Accuracy ±0.1% 120Hz= 120 Hz 1KHz =1010 Hz
Backlit display Excluded
Tolerance mode 1%, 5%, 10%
Test Signal Level 0.6Vrms approx
Measuring Rate 1 time/second, nominal
Response time Approx. 1 second/ DUT (device under test)
(@ manual range)
Auto Power-Off 5 minutes approx. without operation
Temperature Coefficient 0.15 x (Specified Accuracy) / °(0-18° or 28-40°)
Operation Temperature 0° to 40°; 0-70% R.H
Storage Temperature -20° to +50°; 0-80% R.H
Low Battery Indication Approx. 6.8V
Power Consumption Approx. 40mA for operation/ 0.08mA after Auto Power-off
Power Requirements 1) DC 9V Battery
2) Ext. DC Adaptor: DC 12Vmin –15Vmax. (Load 50mA Min.)
Protective Fuse 0.1A/250V Fuse (input protective)
Standard Accessories Test alligator clips (pair)
DC 9V Battery.
User manual




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




BK 110% Price Match Guarantee

Quote Request

We Take POs, How To Order

Free Shipping on BK










Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET