BK 5105B 150MHz (1GS/s) Analog/Digital Oscilloscope

Click image to enlarge
BK 5105B
|
|
Features:
- 1GS/s Real time sampling
- Auto set
- Save/recall
- Readout cursors
- Time base 50s to 5ns
- 8-Bit low noise flash A/D converters
- Pre and post trigger – 100% to +400%
- Acquisition modes: Single Event, Refresh, Average, Envelope, Roll, Peak-Detect
- On screen Help information
- RS-232 Interface Advantages of Analog over Digital:
- Analog scopes display signals in real time.
- Analog scopes can catch “rare events” that DSOs can miss due to their sampling rate limitations.
- Analog scope are not limited in vertical resolution by 8 or 12 bit A/D converters that can lose signal details during the digitizing process.
- Analog copes have a frequency response which closely follows the Gaussian curve, this means in practice that frequencies far beyond the -3dB frequency will be shown. The amplitude will be reduced but they will be shown. Advantages of the added digital operation:
- Capture and storage of single events for event analysis
- There will be no screen flicker with very low frequency signals.
- Fast signals with a low repetition rate response and low duty cycle can be displayed with high intensity
|
Description
|
The model 5105B is a 150 MHz (1GS/s) Analog/Digital Storage Oscilloscope. It is a high performance 150MHz analog oscilloscope with the capability to digitize and store waveforms with its 1GS/s A/D Converters. After the digital acquisition the data can be manipulated and displayed for examination.
The digital capabilities offer the ability for one shot events, you can see what happened before the trigger. After acquisition, the data can be manipulated and displayed in many different ways. You can change time base or vertical position. You can select which portion of a waveform you'd like to look at in more depth. You can compare the measured waveform to a "known good" waveform in memory.
|
Additional Images
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 5105B |
150MHz, 1GS/s, Digital Storage Scope, w/RS-232 Interface - Discontinued - suggested replacement: Instek GRS-6052A |
| Model |
Accessories |
List Price |
Sale Price |
| LC 201A |
Please call or email us for pricing and availability. |
| PR 150 |
150 MHz 1x/10x Oscilloscope Probe |
| $57.00 |  |
|
Specifications
| Vertical Deflection |
| Channels |
| Analog |
2 |
| Digital |
2 + 2 Logic Channels |
| Operating Modes |
| Analog |
CH 1 or CH 2 separate, DUAL (CH 1 and CH 2 alternate or chopped), Addition |
| Digital |
Analog Signal Channels: CH 1 or CH 2 separate, DUAL (CH 1 and CH 2), Addition Logic Signal Channels: CH 3 and CH 4 |
| Y in XY-Mode |
CH 1 |
| Invert |
CH 1, CH 2 |
| Bandwidth (-3 dB) |
2 × 0 - 150 MHz |
| Rise time |
< 2.3 ns |
| Overshoot |
max. 1% |
| Deflection Coefficient (CH 1, 2) |
14 calibrated steps |
| 1 mV - 2 mV/cm (10 MHz) |
±5% (0 - 10 MHz (-3 dB)) |
| 5 mV - 20 V/cm |
±3% (1-2-5 sequence) |
| Variable (uncalibrated) |
> 2.5:1 to > 50 V/cm |
| Inputs CH 1, 2 |
| Impedance |
1 MΩ // 15 pF |
| Coupling |
DC, AC, GND (ground) |
| Max. Input Voltage |
400 V (DC + peak AC) |
| Y Delay Line (analog) |
70 ns |
| Measuring Circuits |
Measuring Category |
| Digital mode only |
| Logic Channels |
CH 3, CH 4 |
| Select. switching thresholds |
TTL, CMOS, ECL |
| User definable thresholds |
3 |
| within the range |
-2 V to +3 V |
| Analog mode only |
| Auxiliary input |
CH 4: 100 V DC + peak AC |
| Function (selectable) |
Extern Trigger, Z (unblank) |
| Coupling |
AC, DC |
| Max. input voltage |
100 V DC + peak AC |
| Triggering |
| Analog and Digital Mode |
| Automatic (Peak to Peak) |
| Min. signal height |
5 mm |
| Frequency range |
10 Hz - 250 MHz |
| Level control range |
from Peak- to Peak+ |
| Normal (without peak) |
| Min. signal height |
5 mm |
| Frequency range |
0 - 250 MHz |
| Level control range |
-10 cm to +10 cm |
| Operating modes |
Slope/Video/Logic |
| Slope |
positive, negative, both |
| Sources |
CH 1, CH 2, alt. 1/2 (≥ 8 mm), Line, Ext. |
| Coupling |
| AC |
(10 Hz - 250 MHz) |
| DC |
(0 - 250 MHz) |
| HF |
(30 kHz - 250 MHz) |
| LF |
(0 - 5 kHz) Noise Rej. switchable |
| Video pos./neg. Sync. Impulse |
| Standards |
525 Line/60 Hz Systems 625 Line/50 Hz Systems |
| Field |
even/odd/both |
| Line |
all/line number selectable |
| Source |
CH 1, CH 2, Ext. |
| Indicator for trigger action |
LED |
| External Trigger via |
CH 4 (0.3 Vpp, 150 MHz) |
| Coupling |
AC, DC |
| Max. input voltage |
100 V DC + peak AC |
| Digital mode |
| Logic |
AND/OR, TRUE/FALSE |
| Source |
CH 1 or 2, CH 3 and CH 4 |
| State |
X, H, L |
| Pre/Post Trigger |
-100% to +400% related to complete memory |
| Analog mode 2nd Trigger |
| Min. signal height |
5 mm |
| Frequency range |
0 - 250 MHz |
| Coupling |
DC |
| Level control range |
-10 cm to +10 cm |
| Horizontal Deflection |
| Analog mode |
| Operating modes |
A, ALT (alternating A/B), B |
| Time base A (Sequence) |
0.5 s/cm - 50 ns/cm (1-2-5 sequence) |
| Time base B (Sequence) |
20 ms/cm - 50 ns/cm (1-2-5 sequence) |
| Accuracy A and B |
±3% |
| X-Mag. ×10 |
to 5 ns/cm |
| Accuracy X ×10 |
±5% |
| Variable time base A/B |
cont. 1:2.5 |
| Hold Off time |
var. 1:10 LED-Indication |
| Bandwidth X-Amplifier |
0 - 3 MHz (-3 dB) |
| X-Y phase shift < 3° |
< 220 kHz |
| Digital mode |
| Time base range (sequence) |
| Refresh Mode |
20 ms/cm - 5 ns/cm (1-2-5 sequence) |
| with Peak Detect |
20 ms/cm - 50 ns/cm (1-2-5 sequence) |
| Roll Mode |
50 s/cm - 50 ms/cm (1-2-5 sequence) |
| Accuracy time base |
| Time base |
50 ppm |
| Display |
±1% |
| MEMORY ZOOM |
max. 40,000:1 |
| Bandwidth X-Amplifier |
0 - 150 MHz (-3 dB) |
| X-Y phase shift < 3° |
< 100 MHz |
| Digital Storage |
| Acquisition (real time) |
Analog channels: 2 × 500 MSa/s, 1 GSa/s interleaved Logic Channels: 2 × 500 MSa/s |
| Acquisition (random sampling) |
Analog channels: 10 GSa/s |
| Bandwidth |
2 × 0 - 150 MHz (random) |
| Memory |
1 M-Samples per channel |
| Operating modes |
Refresh, Average, Envelope/Roll: Free Run/Triggered,Peak-Detect |
| Resolution (vertical) |
8 Bit (25 Pts/cm) |
| Resolution (horizontal) |
| Yt |
11 Bit (200 Pts/cm) |
| XY |
8 Bit (25 Pts /cm) |
| Interpolation |
Sinx/x, Dot Join (linear), Pulse |
| Delay |
1 Million * 1/Sampling Rate to 4 Million * 1/Sampling Rate |
| Display refresh rate |
max. 170/s at 1 MPts |
| Display |
Yt, XY (acquired points only), Interpolation, Dot Join |
| Reference Memories |
9 with 2 kPts each (for recorded signals) |
| Display |
2 signals of 9 (free selectable) |
| Operation/Measuring/Interfaces |
| Operation |
Menu (multilingual), Autoset, help functions (multilingual) |
| Save/Recall (instrument parameter settings) |
9 |
| Signal display |
max. 4 signals or 4 traces |
| Analog |
CH 1, 2 (Time Base A) in combination with CH 1, 2 (Time Base B) |
| Digital |
CH 1, 2 and CH 3, 4 or ZOOM or Reference or Mathematics |
| Frequency counter |
| 6 digit resolution |
> 1 MHz - 250 MHz |
| 5 digit resolution |
0.5 Hz - 1 MHz |
| Accuracy |
50 ppm |
| Auto Measurements |
| Analog mode |
Frequency, Period, Vdc, Vpp, Vp+, Vp- add. in digital mode Vrms/Vavg |
| Cursor Measurements |
| Analog mode |
ΔV, Δt, 1/Δt (f), V to GND, ratio X, ratio Y |
| add. in digital mode |
Pulse count, Vt to Trigger Peak to Peak, Peak+, Peak- |
| Resolution Readout/Cursor |
1000 × 2000 Pts, Signals: 250 × 2000 |
| Interfaces (plug-in) |
RS-232 |
| Mathematic functions |
| Number of Formula Sets |
5 with 5 formulas each |
| Sources |
CH 1, CH 2, Math 1-Math 5 |
| Targets |
5 math. memories, Math 1-5 |
| Functions |
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS, NEG, INV |
| Display |
max. 2 math. memories (Math 1-5) |
| Display |
| CRT |
D14-375GH |
| Display area (with graticule) |
8 cm × 10 cm |
| Acceleration voltage |
approx. 14 kV |
| General Information |
| Component tester |
| Test voltage |
approx. 7 Vrms (open circuit), approx. 50 Hz |
| Test current |
max. 7 mArms (short circuit) |
| Reference Potential |
Ground (safety earth) |
| Probe ADJ Output |
1 kHz/1 MHz square wave signal 0.2 Vpp (tr < 4 ns) |
| Trace rotation |
electronic |
| Line voltage |
105 - 253 V, 50/60 Hz ±10%, CAT II |
| Power consumption |
47 Watt at 230 V, 50 Hz |
| Protective system |
Safety class I (EN61010-1) |
| Weight |
5.6 kg |
| Cabinet (W × H × D) |
285 × 125 × 380 mm |
| Ambient temperature |
0°C ... +40°C |
| Accessories supplied |
Line cord, Operating manual, 4 Probes 10:1 with attenuation ID, Windows Software for control and data transfer |
|