| DC Volts |
| Ranges |
660 mV, 6.6 V, 66 V, 660 V, 1000 V |
| Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
| Accuracy |
±(0.5 % rdg + 2 dgts) |
| Input Impedance |
660 mV: >100 MΩ 6.6 V: 10 MΩ 66 V to 1000 V: 9.1 MΩ |
| Overload Protection |
1000 VDC or 750 VACrms |
| AC Volts (50 Hz-500 Hz) |
| Ranges |
660 mv, 6.6 V, 66 V, 660 V, 750 V |
| Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
| Accuracy |
660 mV range at 50 Hz to 60 Hz ±(1.5 % rdg + 8 dgts) 6.6 V to 660 V ranges: ±(1.5 % rdg + 8 dgts) 750 V range: ±(2.0 % rdg + 8 dgts) |
| Input Impedance |
660 mV: >100 MΩ 6.6 V: 10 MΩ 66 V to 750 V: 9.1 MΩ |
| Overload Protection |
1000 VDC or 750 VACrms* |
| DC Current |
| Ranges |
660 uA, 6600 uA, 66 mA, 400 mA, 10 A |
| Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
| Accuracy |
660 uA to 400 mA ranges: ±(1.5 % rdg + 2 dgts) 10 A range: ±(3.0 % rdg + 3 dgts) |
| Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses |
| AC Current (50 Hz-500 Hz) |
| Ranges |
660 uA, 6600 uA, 66 mA, 400 mA, 10 A |
| Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
| Accuracy |
660 uA to 400 mA ranges: ±(2.0 % rdg + 10 dgts) 10 A range: ±(3.5 % rdg + 10 dgts) |
| Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses |
| Resistance |
| Ranges |
660 Ω, 6.6 kΩ, 660 kΩ, 6.6 MΩ, 66 MΩ |
| Resolution |
0.1 Ω, 1.0 Ω, 10 Ω, 1 kΩ, 10 kΩ |
| Accuracy |
660 Ω to 660 kΩ ranges: ±(1.2 % rdg + 5 dgts) 6.6 MΩ range: ±(2.0 % rdg + 5 dgts) 66 MΩ range: ±(3.5 % rdg + 5 dgts) |
| Open Circuit Voltage (typical) |
-0.45 VDC (-1.2 VDC on 660 Ω range) |
| Overload Protection |
500 VDC/ACrms |
| Capacitance |
| Ranges |
6.6 nF , 66 nF, 660 nF, 6.6 uF, 66 uF, 660 uF, 6.6 mF, 66 mF |
| Resolution |
1 pF, 10 pF, 100 pF, 1 nF, 10 nF, 100 nF, 1 uF, 10 uF |
| Accuracy |
6.6 nF range: ±(3.0 % rdg + 30 dgts) 66 nF to 660 uF ranges: ±(3.0 % rdg + 5 dgts) 6.6 mF to 66 mF ranges: ±(5.0 % rdg + 20 dgts) |
| Overload Protection |
500 VDC/ACrms |
| Frequency |
| Ranges |
660 Hz, 6.6 kHz, 66 kHz, 660 kHz, 6.6 MHz, 66 MHz |
| Resolution |
0.1 Hz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz |
| Accuracy |
±(0.1 % rdg + 3 dgts) |
| Sensitivity |
10 Hz to 6.6 MHz: >2.5 Vrms, 6.6 MHz to 66 MHz: >2.5 Vrms <5 Vrms |
| Overload Protection |
500 VDC/AC rms |
| Diode Test |
| Test Current |
1.2 mA (typical) |
| Resolution |
1 mV |
| Accuracy |
±(1.5 % rdg + 3 dgts) |
| Open Circuit Voltage |
3.5 VDC (typical) |
| Overload Protection |
500 VDC/ACrms |
| Continuity |
| Audible Indication |
Less than 30 Ω |
| Response Time |
100 ms |
| Overload Protection |
500 VDC/ACrms |
| General |
| Display |
3 3/4 digit, 6600 count LCD |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
OL or -OL is displayed |
| Low Battery Indication |
The battery symbol will display when battery voltage drops below operating levels |
| Measurement Rate |
2 times per second |
| Auto Power Off |
Approximately 30 minutes |
| Operating Environment |
0ºC to 50ºC at <70 % relative humidity |
| Storage Environment |
-20ºC to 60ºC at 0 to 80 % relative humidity |
| Accuracies |
Stated accuracy at 23ºC +5ºC at <75 % relative humidity |
| Temperature Coefficient |
0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC) |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
150 hours typical |
| Dimensions |
165 mm (H) x 78 mm (W) x 42.5 mm (D) |
| Weight |
Approximately 10.3 oz. (377 g) with battery and hanger |
| * 600 VDC/Acrms for 15 seconds on 200 mV range |