| DC Volts |
| Ranges |
340 mV, 3.4 V, 34 V, 340 V, 1000V |
| Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
| Accuracy |
±(1.0 % rdg + 2 dgts) |
| Input Impedance |
340 mV: >100 MΩ; 3.4 V: 10 MΩ; 34 V to 1000 V: 9.1 MΩ |
| Overload Protection |
1000 VDC or 750 VACrms |
| AC Volts (50 Hz-500 Hz) |
| Ranges |
3.4 V, 34 V, 340 V, 750 V |
| Resolution |
1 mV, 10 mV, 100 mV, 1 V |
| Accuracy |
3.4 V & 34 V ranges: ±(2.0 % rdg + 8 dgts) 340 V & 750 V ranges: ±(2.0 % rdg + 8 dgts) |
| Input Impedance |
3.4 V: 10 MΩ; 34 V to 1000 V: 9.1 MΩ |
| Overload Protection |
1000 VDC or 750 VACrms* |
| DC Current |
| Ranges |
340 uA, 3400 uA, 34 mA, 340 mA, 10 A |
| Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
| Accuracy |
340 uA to 340 mA ranges: ±(2.0 % rdg + 2 dgts) 10 A range: ±(3.0 % rdg + 3 dgts) |
| Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses |
| AC Current (50 Hz-500 Hz) |
| Ranges |
340 uA, 3400 uA, 34 mA, 340 mA, 10 A |
| Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
| Accuracy |
340 uA to 340 mA ranges: ±(2.5 % rdg + 10 dgts) 10 A range: ±(3.5 % rdg + 10 dgts) |
| Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses |
| Resistance |
| Ranges |
340 Ω, 3.4 kΩ, 34 kΩ, 340 kΩ, 3.4 MΩ, 34 MΩ |
| Resolution |
0.1 Ω, 1.0 Ω, 10 Ω, 100 MΩ, 1 kΩ, 10 kΩ |
| Accuracy |
340 Ω to 340 kΩ ranges: ±(1.5 % rdg + 4 dgts) 3.4 MΩ range: ±(2.5 % rdg + 4 dgts) 34 MΩ range: ±(5.0 % rdg + 5 dgts) |
| Open Circuit Voltage (typical) |
-0.45 VDC (-1.2 VDC on 660 Ω range) |
| Overload Protection |
500 VDC/ACrms |
| Diode Test |
| Test Current |
1.0 mA (typical) |
| Resolution |
10 mV |
| Accuracy |
±(3.0 % rdg + 3 dgts) |
| Open Circuit Voltage |
3.0 VDC (typical) |
| Overload Protection |
500 VDC/ACrms |
| Continuity |
| Audible Indication |
Less than 35 Ω |
| Response Time |
500 ms |
| Overload Protection |
500 VDC/ACrms |
| General |
| Display |
3 3/4 digit, 6600 count LCD |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
OL or -OL is displayed |
| Low Battery Indication |
The battery symbol will display when battery voltage drops below operating levels |
| Measurement Rate |
2 times per second |
| Auto Power Off |
Approximately 30 minutes |
| Operating Environment |
0ºC to 50ºC at <70 % relative humidity |
| Storage Environment |
-20ºC to 60ºC at 0 to 80 % relative humidity |
| Accuracies |
Stated accuracy at 23ºC +5ºC at <75 % relative humidity |
| Temperature Coefficient |
0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC) |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
150 hours typical |
| Dimensions |
165 mm (H) x 78 mm (W) x 42.5 mm (D) |
| Weight |
Approximately 10.3 oz. (377 g) with battery and hanger |
| * 600 VDC/Acrms for 15 seconds on 200 mV range |