| DC Volts |
| Ranges |
200 mV, 2 V, 20 V, 200 V, 1000V |
| Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
| Accuracy |
±(0.8 % rdg + 1 dgts) |
| Input Impedance |
10 MΩ |
| Overload Protection |
1000 VDC or 750 VACrms* |
| AC Volts (50 Hz-500 Hz) |
| Ranges |
200 mV, 2 V, 20 V, 200 V, 750V |
| Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
| Accuracy |
200 mV & 20 V ranges: ±(1.5 % rdg + 5 dgts) 200 V & 750 V ranges: ±(2.0 % rdg + 5 dgts) |
| Input Impedance |
10 MΩ |
| Overload Protection |
1000 VDC or 750 VACrms* |
| DC Current |
| Ranges |
20 mA, 200 mA, 10 A |
| Resolution |
10 uA, 100 uA, 10 mA |
| Accuracy |
20 mA to 200 mA ranges: ±(1.0 % rdg + 1 dgts) 10 A range: ±(3.5 % rdg + 3 dgts) |
| Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses |
| 10A Input |
10 A for 60 sec max. followed by a 10 minute cooling period |
| AC Current (50 Hz-500 Hz) |
| Ranges |
20 mA, 200 mA, 10 A |
| Resolution |
10 uA, 100 uA, 10 mA |
| Accuracy |
20 mA to 200 mA ranges: ±(2.0 % rdg + 5 dgts) 10 A range: ±(3.5 % rdg + 5 dgts) |
| Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses |
| 10A Input |
10 A for 60 sec max. followed by a 10 minute cooling period |
| Resistance |
| Ranges |
200 Ω, 2 kΩ, 200 kΩ, 20 MΩ, 2000 MΩ |
| Resolution |
0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ, 1 MΩ |
| Accuracy |
200 Ω to 200 kΩ ranges: ±(1.0 % rdg + 4 dgts) 20 MΩ range: ±(2.0 % rdg + 4 dgts) 2000 MΩ range: ±(5.0 % rdg + 10 dgts) |
| Open Circuit Voltage (typical) |
0.3 VDC (3.0 VDC on 200 Ω, 2000 MΩ range) |
| Overload Protection |
500 VDC/ACrms |
| Capacitance |
| Ranges |
2 nF , 20 nF, 200 nF, 2.0 uF, 20 uF |
| Resolution |
1 pF, 10 pF, 100 pF, 1 nF, 10 nF |
| Accuracy |
±(4 % rdg + 10 dgts) |
| Overload Protection |
Discharge capacitor before connecting |
| Frequency |
| Ranges |
2 kHz, 20 kHz, 200 kHz, 2 MHz, 20 MHz |
| Resolution |
1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz |
| Accuracy |
±(0.1 % rdg + 3 dgts) |
| Sensitivity |
2.0 Vrms minimum |
| Minimum Pulse Width |
>25 ns |
| Duty Cycle Limits |
>30 % and <70 % |
| Overload Protection |
500 VDC/AC rms |
| Diode Test |
| Test Current |
1.0 mA (typical) |
| Resolution |
10 mV |
| Accuracy |
±(1.5 % rdg + 3 dgts) |
| Open Circuit Voltage |
3.0 VDC (typical) |
| Overload Protection |
500 VDC/ACrms |
| Continuity |
| Audible Indication |
Less than 100 Ω |
| Response Time |
100 ms |
| Overload Protection |
500 VDC/ACrms |
| Transis tor hFE |
| Ranges |
0 to 1000 |
| Base Current |
Approximately 10 uADC (VCE = 3.0 VDC) |
| Logic Test |
| Threshold |
Logic Hi (2.8 V +0.8 V) / Logic Lo (0.8 V +0.5 V) |
| Indication |
40 msec beep at logic Lo |
| Overload Protection |
500 VDC/AC rms |
| General |
| Display |
3 1/2 digit, 2000 count LCD |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
OL or -OL is displayed |
| Low Battery Indication |
The battery symbol will display when battery voltage drops below operating levels |
| Measurement Rate |
2.5 times per second |
| Auto Power Off |
Approximately 30 minutes |
| Operating Environment |
0șC to 50șC at <70 % relative humidity |
| Storage Environment |
-20șC to 60șC at 0 to 80 % relative humidity |
| Accuracies |
Stated accuracy at 23șC +5șC at <75 % relative humidity |
| Temperature Coefficient |
0.1 x (specified accuracy) per șC. (șC to 18șC, 28șC to 50șC) |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
150 hours typical |
| Dimensions |
165 mm (H) x 78 mm (W) x 42.5 mm (D) |
| Weight |
Approximately 10.3 oz. (377 g) with battery and hanger |
| * 600 VDC/Acrms for 15 seconds on 200 mV range |