3.3 GHz Handheld Spectrum Analyzer with Tracking Generator
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




BK 2652
3.3 GHz Handheld Spectrum Analyzer with Tracking Generator



BK 2652
Click image to enlarge

 BK 2652

Features:
  • Frequency response measurements of passive components such as RF cables, filters, and attenuators
  • Installation, maintenance, and trouble shooting of wireless communication systems such as W-CDMA/CDMA, GSM, WLAN and Bluetooth
  • Detection of signal interference and undesired emissions
  • TV and broadcasting
  • Antenna alignment
  • EMI compliance (E & H field measurements with optional accessories)



  Description

B+K Precision’s 2652 handheld spectrum analyzer is small and exceptionally light weight, yet delivers performance and features comparable to a full size bench spectrum analyzer. The 2652 is a 2650 with a tracking generator added and can be used to rapidly determine transmission characteristics of two-port RF devices. With its ease of use, great performance and broad functionality, the 2652 is an ideal tool for engineers and technicians who perform field measurements in the 50kHz to 3.3GHz range.




  Models, Options, & Accessories


Model Description List Price Sale Price
2652 Handheld 3.3GHz Spectrum Analyzer with Tracking Generator
$6950.00 
Model Accessories List Price Sale Price
AK 2650 PC Interface Software for model 2650/2658
$286.00 
AN 301 Dipole Antenna (0.8 to 1GHz) for model 2650/2658
$234.00 
AN 302 Dipole Antenna (1.25 to 1.65GHz) for model 2650/2658
$234.00 
AN 303 Dipole Antenna (1.7 to 2.2GHz) for model 2650/2658
$234.00 
AN 304 Dipole Antenna (2.25 to 2.65GHz) for model 2650/2658
$234.00 
AN 305 Dipole Antenna (390 to 410MHz) for model 2650/2658
$305.00 
AN 306 Dipole Antenna (4.7 to 6.2GHz) for model 2658
$309.00 
BC 2650 120V, 60Hz AC Adapter for model 2650/2658
$192.00 
BP 2650 Ni-MH Battery Pack for model 2650/2658
$192.00 
CC265 Deluxe Spectrum Analyzer Accessory Kit for 2650/2652/2658
$154.00 
LC 2650 Soft Carrying Case for models 2650/2658
$176.80 
PR 26M Magnetic Field Probe for model 2650/2658
$3200.00 
PT 2650 Printer for model 2650/2658
$551.20 
PX 2650 Roll Paper for PT 2650 (10 Rolls)
$98.80 



  Specifications

Frequency section
Frequency range 50kHz to 3.3GHz
Center frequency
Resolution 100kHz
Settable via rotary encoder, numeric or function key
Accuracy within ±(30 + 20T)kHz ± 1dot
@frequency span: 200kHz to 10MHz, RBW- 30kHz, 23 ± 5°C

within ±(100 + 700T)kHz ± 1dot
@frequency span: 20MHz to 3.3GHz, RBW- 100kHz, 23 ± 5°C
RBW frequency error within ±6% of RBW @RBW: 3kHz, 30kHz
within ±30% of RBW @RBW: 100kHz to 3MHz
Frequency span
Range 0Hz (zero span)
200kHz to 2GHz (1-2-5 step) and 3.3GHz
Accuracy within ±3% ± 20TkHz ± 1dot
@frequency span: 200kHz to 10MHz, 23 ± 5°C

within ±3% ± 200TkHz ± 1dot
@frequency span: 20MHz to 3.3GHz, 23 ± 5°C
Display resolution
(horizontal)
Frequency span/250
The unit displays 251 horizontal dots but stores 1001 trace data points internally which can be captured via RS232 interface
Resolution bandwidth (-3dB bandwidth)
Range 3kHz to 3MHz (1-3 step) and AUTO
Accuracy within ±20%
Shape Factor 1to12 (typical, 3dBto60dB)
Video bandwidth 100Hz to 1MHz (1-3 step), AUTO
SSB phase noise -90dBc/Hz (typical) @100kHz offset, RBW- 3kHz, VBW- 100Hz, Sweep time- 0.3s
Spurious response < -60dBc
Harmonics < -40dBc @100MHz to 3.3GHz
Amplitude section
Reference level
Range +10 to -60dBm (1dB step)
Accuracy within ±0.8dB ± 1dot
@center frequency: 100MHz, RBW- 3MHz, VBW- 1MHz, ATT- 0dB, 23 ± 5°C
Unit dBm, dBV, dBmV, dBµV, dBµV/m, dBµA/m
(dBµV/m and dBµA/m are available for certain measurement functions)
Average noise level -110dBm (typical)
@center frequency- 100MHz, RBW- 3kHz, VBW- 100Hz
Frequency response Within ±2.0dB ± 1dot @50kHz to 100MHz
Within ±1.0dB ± 1dot @100MHz to 3.3GHz
Input impedance 50Ω
Input VSWR < 2.0
Input attenuator
Operating range 0 to 25dB (1dB step), coupled with reference level
Switching error within ±0.6dB @100MHz
RBW switching error within ±0.6dB
Display resolution 200 dots
Display scale
Scale 10dB/div, 2dB/div
Accuracy within ±0.8dB/10dB ± 1dot
within ±0.2dB/2dB ± 1dot
within ±1.6dB/70dB ± 1dot
Input damage level +23dBm (CW average power), 25VDC
Sweep section
Sweep time
Range 10ms to 30s and AUTO (1-3 step) @ 0 to 2GHz span
30ms to 30s and AUTO (1-3 step) @full span
Accuracy within ±0.1% ± 1dot @ 0 to 2GHz span
within ±1.5% ± 1dot @ full span
Trigger mode AUTO (frequency span: zero span)
Detection mode Positive peak, Negative peak, Sample
Measurement and Calculation Functions
Markers NORM- displays frequency (7 digits max) and level (4 digits max) at marker point.
DELTA- displays ∆f (Frequency) and ∆dBx (level)
Peak search NORM- searches a peak point within full range. This mode also supports NEXT peak (10max).
ZONE- searches a peak point within a zone defined by center and width.
Calculations NORM, MAX HOLD, MIN HOLD, AVERAGE, OVER WRITE
MAX/MIN HOLD- 2 to 1024 times
AVERAGE- 2 to 256
Measurements Measure Channel power, Adjacent channel leakage power, Occupied frequency bandwidth, Electric field strength (requires antenna), Magnetic field strength (requires magnetic field probe)
AUTO tuning Automatically scans the full bandwidth, detects the maximum level spectrum and centers it on screen. Automatically adjusts reference level, RBW, VBW and sweep time to optimum levels.
Tracking Generator
Frequency range 5MHz to 3.3GHz
Output Level -10dBm ± 1dB @1GHz (fixed)
Output flatness ±1.5dB
Output impedance 50Ω
VSWR < 2.0
Output connector SMA (J)
General
Input connector SMA (J)
Save/Load
Save Saves 100 traces and 100 setups
Load Loads 1 trace and 1 setup
Communications
Interface RS-232C
Baud rate 2,400 to 38,400bps
Hard copy (Allows direct hard copy with optional printer.)
Display
Display LCD
Backlight CFL backlight
Resolution 320 (H) × 240 (V) dots
Power source
Battery Ni-MH battery
Operating Time Approx. 110 min. with the backlight turned off (battery fully charged)
External DC source DC jack, +4.75 to +5.25VDC/4A
Immunity of radiated interference
Level display at 10V/m
Less than -35dBc (reference level- 10dBm)
Immunity to cabled interference
Level display at transient interference of 4.0kV
Less than -30dBc (reference level: 10dBm)
Environmental and size
Operating temperature 0 to 50°C (Guaranteed at 23 ± 10°C, without soft carrying case)
Operating humidity less than 40°C/80%RH
(Guaranteed at less than 33°C/70%RH, without soft carrying case)
Storage temperature -20 to 60°C, less than 60°C/70%RH
Dimensions 162 (W) × 70 (H) × 260 (D) mm
6.38 (W) × 2.76(H) × 10.25 (D) inch
(exclude projections and stand)
Weight approx. 4lbs (1.8kg), including battery
approx. 3.3lbs (1.5kg) without battery



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET