Our agents are available:
9:00 AM - 6:00 PM EST
Amprobe PM51A Shirt-Pocket DMM w/ Frequency & Capacitance
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Amprobe PM51A Shirt-Pocket DMM w/ Frequency & Capacitance




Click image to enlarge

 Amprobe PM51A




Click image to enlarge

Features:
  • Measures ac and dc voltage, resistance, continuity w/ beeper, capacitance and frequency
  • Fully autoranging with 7 measurement functions and 27 ranges
  • Large oversize digital display with measurement results and the unit icon
  • Data Hold freezes measurement value on
  • Average sensing
  • Power consumption (typical) 2 mA
  • Automatic Power Off , timing Idle for 30 minutes
  • APO consumption (typical) 2.2 µA
  • E.M.C. Meets EN61326
  • Audible Continuity Tester Open circuit voltage 0.4 V dc typical
  • Diode Tester Test current (typical) 0.25 mA
  • Diode Tester Open circuit voltage 1.6 V dc
  • Battery installed, and User’s manual
Includes:
  • Battery (installed)
  • Users manual

UL & CE Listed, CAT III 300 V, CAT 600 V



  Description

PM51A - Shirt-Pocket DMM w/ Frequency & Capacitance

This shirt-pocket sized meter isonly 3/8" thick and weighs less than 3 oz.With full functionality offering ac and dc voltage to600 V, resistance to 40 Megohm, capacitance to 3000 µF, frequencyto 1 MHz, continuity w/beeper,and diode test.

Fully autoranging, this meter offers seven different measurement functions with 27 full ranges of measurement. The digital display is oversized with large digits and annunciators. In spite ofits size, this meter is fully safetyrated to CAT III 300 V, CAT II 600 Vand is UL listed. No other meter offers this small size with such performance and high safety ratings.



  Models, Options, & Accessories


Model Description List Price Sale Price
PM51A POCKET DMM W FREQ AND CAPACITANCE $28.95
$25.19 
Model Accessories List Price Sale Price
H-PM Please call or email us for pricing and availability.
VC3 Please call or email us for pricing and availability.



  Specifications

Display and update rate 3-3/4 digits 4000 counts; Updates 3 per second nominal
Operating temperature 0°C - 40°C
Relative humidity Max. 80 % R.H. up to 31°C, decreasing linearly to 50 % R.H. at 40°C
Altitude Operating below 2000 m
Storage temperature -20°C ~ 60°C, < 80 % R.H. (with battery removed)
Temperature coefficient Nominal 0.15 x (specified accuracy)/ °C @ (0°C ~ 18°C or 28°C ~ 40°C), or otherwise specified
Sensing Average sensing
Overload protection 600 V dc and V ac rms
Low battery Below approx. 2.4 V
Power supply 3 V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC)
Power consumption (typical) 2 mA
Automatic Power Off (APO) timing Idle for 30 minutes
APO consumption (typical) 2.2 μA
Dimension L 113 mm x W 53 mm x H 10.2 mm (4.4 x 2.1 x 0.4 in)
Weight Approx. 78 gm (3 oz)
Special features Data Hold, and 30 ms MAX Hold
Agency approvals CE, cULus
Safety Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2 No. 1010.1-92, CAT II 600 V and CAT III 300 V,
Pollution Degree 2, Class 2
E.M.C. Meets EN61326
Function Range Accuracy
DC Voltage
  400.0 mV ± (1.0 %+2 dgt)
  4.000 V, 40.00 V, 400.0 V ± (2.0 %+2 dgt)
  600 V ± (2.5 %+4 dgt)
NMRR > 50 dB @ 50 Hz/60 Hz  
CMRR > 120 dB @ dc, 50 Hz/60 Hz; Rs=1 kW  
Input impedance 10 MΩ, 30 pF nominal; (1000 MW for 400.0 mV range)  
AC Voltage
50 Hz - 60 Hz 4.000 V, 40.00 V, 400.0 V ± (2.0 %+5 dgt)
60 Hz - 500 Hz 4.000 V, 40.00 V, 400.0 V ± (3.0 %+5 dgt)
50 Hz - 500 Hz 600 V ± (3.5 %+5 dgt)
Input impedance 10 MW, 30 pF nominal  
CMRR > 60 dB @ dc to 60 Hz, Rs=1 kW  
Capacitance
  500.0 nF, 5.000 μF, 50.00 μF  
  500.0 μF, 3000 μF 1 3 ± (3.5 %+6 dgt4)
1Additional 50.00 nF range accuracy is not specified
2Accuracies with film capacitor or better
3Updates > 1 minute on large values
4Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of
approx 2.4 V.
Resistance
  400.0 Ω ± (1.5 %+6 dgt)
  4.000 KΩ , 40.00 KΩ , 400.0 KΩ ± (1.0 %+4 dgt)
  4.000 MΩ ± (1.5 %+4 dgt)
  40.00 MΩ ± (2.5 %+4 dgt)
Open circuit voltage 0.4 V DC typical  
Frequency
  400 Hz, 4 kHz, 40 kHz, 400 kHz, 1 MHz 1 ± (0.5 %+4 dgt)
1Specified at input voltage < 20 V ac rms input signal: Sine-wave, or square-wave with duty cycle > 40 % & < 70 %
Sensitivity (V-peak)
  5 Hz - 100 kHz > 1.3 Vp
  100 kHz - 500 kHz > 2.2 Vp
  500 kHz - 1 MHz > 4.2 Vp
Diode Tester
Test current (typical) 0.25 mA  
Open circuit voltage 1.6 V dc  
Audible Continuity Tester
Open circuit voltage 0.4 V dc typical  
Audible threshold 65 Ω ±55 Ω  



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET