| General Specifications |
| Display |
3-1/2 digit LCD, 1999 counts, with annunciators and menu features |
| Polarity Indication |
Automatic |
| Input overload indication |
1 |
| Low Battery Indication |
< 50 hours battery life remain, accuracy is no longer guaranteed |
| Display Update Rate |
2.5/sec, nominal |
| Oper. Temp. |
0 °C to +50 °C, (< 75 % R.H.) |
| Storage Temp |
-20 °C to 60 °C, 0 to 80 % RH, battery removed |
| Temperature coefficient |
0.1 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) all functions and ranges except for mVDC 0.3 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) for mVDC |
| Altitude |
Up to 2000 m — indoor use |
| Fuse |
F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700 |
| Power |
Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F22 |
| Auto Power-Down |
Meter powers down after approx. 30 min. of inactivity. |
| Battery Life |
250 hours typical with carbon-zinc, 500 hours typical with alkaline |
| Dimensions, with holster (H x W x D) |
200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) |
| Weight (incl. battery) |
642 g (20 oz) |
| Accessories |
Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (in instrument), hex wrench in holster, Magne-Grip flex strap and User Manual |
| Case material |
Flame retardant, high-impact thermoplastic |
| Safety |
Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 |
| EMC |
Meets EN 61326-1 |
| DC Volts Ranges |
200 mV, 2 V, 20 V, 200 V, 1500 V |
| DC Volts Resolution |
0.1 mV |
| DC Volts Accuracy |
All ranges ±(0.1 % rdg+2 dgts) |
| DC Volts Input Impedance |
10 MÙ |
| DC Volts OL Protection |
1500 V dc/1000 V ac rms |
| DC Volts Transient Protection |
12 kV impulse (1.2 ìS/50 ìS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
| AC Volts (45 Hz to 2 kHz) Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V |
| AC Volts (45 Hz to 2 kHz) Resolution |
0.1 mV |
| AC Volts (45 Hz to 2 kHz) Accuracy |
200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts), |
| AC Volts (45 Hz to 2 kHz) Accuracy |
200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) |
| AC Volts (45 Hz to 2 kHz) Accuracy |
1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) |
| AC Volts (45 Hz to 2 kHz) Accuracy |
1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) |
| AC Volts (45 Hz to 2 kHz) Input Impedance |
10 MÙ |
| AC Volts (45 Hz to 2 kHz) OL Protection |
1500 V dc/1000 V ac rms |
| AC Volts (45 Hz to 2 kHz) Transient Protection |
12 kV impulse (1.2 ìS/50 ìS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV. |
| DC Current Ranges |
200 ìA, 2 mA, 20 mA, 200 mA, 2 A |
| DC Current Resolution |
0.1 ìA |
| DC Current Accuracy |
200 ìA to 20 mA ±(0.5 % rdg+2 dgts) |
| DC Current Accuracy |
200 mA to 2 A ±(1.0 % rdg+2 dgts) |
| DC Current Voltage Burden |
250 mV max. (1 mV/1 ìA on 200 ìA Range) |
| DC Current Voltage Burden |
100 mV/1 mA on 2 mA Range) |
| DC Current Voltage Burden |
(10 mV/1 mA on 20 mA Range) |
| DC Current Voltage Burden |
(1.5 mV/1 mA on 200 mA Range) |
| DC Current Voltage Burden |
(500 mV/1 A on 2 A Range) |
| DC Current OL Protection |
A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) (FP 700) |