Our agents are available:
9:00 AM - 6:00 PM EST
Amprobe ACF-3000SR 3000A Flexible Current Transducer
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Amprobe ACF-3000SR 3000A Flexible Current Transducer




Click image to enlarge

 Amprobe ACF-3000SR

Features:
  • Accessory for the DM-III (recorders marked as the DM-III on the front label*) and the MT-2000
  • Current measurement from 15A to 3000A for each of the three phases
  • Neutral wire current measurement down to milliamps for the DM-III
  • Flexible head fits all small conductors and large bus-bars up to 7" in diameter
  • Recommended one ACF-3000 SR for single phase system, and three for three phase systems
  • Output Sensitivity (AC coupled): 0.333mV per Amp
  • Accuracy: ±1% of range
  • Safety: CATIII 600
*For recorders marked as the DM-IIIS on the front label use the FLEX3 flexible CT.




  Models, Options, & Accessories


Model Description List Price Sale Price
ACF-3000SR 3000A FLEXIBLE CURRENT TRANSDUCER F/ DM-III $499.95
$434.96 
Model Accessories List Price Sale Price
ACF-3A EXTERNAL POWER SUPPLY $25.95
$22.58 



  Specifications

General Characteristics
Head Cable Colour Yellow
Head Cable Length (double insulated) 24 inches (610mm)
Head Cable Diameter 0.562 inches (14.3 mm)
Head Bend Radius 1.5 inches (38.1 mm)
Cable Length (head to electronics) 78.7 inches (2 meters)
Output Connection Hypotronics D01EEB306FST
Operating Temperature Range -4 to 194°F (-20 to +90°C) head
-4 to 185°F (-20 to +85°C) electronics
Storage Temperature Range -40 to 221°F (-40 to +105°C) head
-4 to 185°F (-20 to +85°C) electronics
Operating Humidity 15% to 85% (non condensing)
Weight 0.40 Lb (180 g) head
The ACF-3000 SR is an AC current probe utilising the Rogowski principle. It can be used to measure currents up to 3000A.
Safety Standards
BSEN61010-1 1993, 600V Cat III, Pol. Deg 2
Use of the probe on uninsulated conductors is limited to 600 V ACRMS or DC and frequencies below 1 kHz.
EMC Standards
EN 61326 1998
Electrical Characteristics
Current Ranges 3000 A ACRMS
Output Sensitivity (AC coupled) 0.333 mV per A
Load Impedance 100 kOhm minimum
Accuracy (at +25°C) ± 1% of range (45 - 65 Hz)
Linearity (10% to 100% of range) ± 0.2% of reading
Noise 0.3 mV ACRMS
Frequency Range 10 Hz to 5 kHz (- 3 dB)
Phase Error < ± 1% (45 - 65Hz), ± 10° (at 5 kHz)
Position Sensitivity (with cable > 25mm from the coupling) ± 2% of range
External Field (with cable > 200mm from the head) ± 1% of range
Power Supply 2 x AAMN 1500 LR6 alkaline 4000 hours, 3000 hrs typical
Low battery indication Red LED
External power Battery eliminator, via 2.1mm connector, 3V DC: Socket type A16M500
Gain variation ± 0.08% of reading per 1.8° F (1° C)
Common mode voltage Voltage between Output and Earth must not exceed 30V
Working Voltage (see Safety Standards section) 600 V ACRMS or DC



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET