Amprobe ACD-30P 1000A Clamp-on Power Meter

Click image to enlarge
Amprobe ACD-30P
|
|
Features:
- TRMS sensing
- AutoVA - Auto Selection of AC Volts, DC Volts or AC Amps
- AC/DC Voltage up to 600V, AC Current up to 1000A, Resistance, Frequency
- Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Auto power off
- Automatic polarity
- Low battery indication
- Peak hold
- Data hold
- Large, easy to read LCD display
- Accommodates conductors up to 1.77” (45mm) in diameter
- Carrying case, test leads, batteries (installed),and manual included
- Voltage overload protection for all functions up to 600V AC/DC
- Limited Life Time Warranty
|
Description
|
These instruments combine the standard features of professional clamp-on meters, with full Power analyzing capabilities! Measure: Active (W), Reactive (VAR) and Apparent (VA) Powers along with dual display Power Factor readout. Increase measuring efficiency with an optional PC interface kit.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| ACD-30P |
1000A CLAMP-ON POWER METER, TRMS - Discontinued - replaced by Amprobe ACD-31P |
| ACD-31P |
1000A CLAMP-ON POWER METER, TRMS W/BACKLIGHT |
$249.95 |
| $217.46 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| RS-232KIT2 |
Please call or email us for pricing and availability. |
| A47L |
POWER LINE SPLITTER AND ENERGIZER - Discontinued - replaced by Amprobe ELS2A |
| CT50-1 |
Current Transducer - Discontinued - replaced by Amprobe CT50-2 |
| CT50-2 |
Current Transducer - Discontinued - no replacement |
| VRC-320 |
SET, PUSH-ON ALLIGATOR CLIPS, 1 RED/1 BLACK - Discontinued - replaced by Amprobe TL36A |
| Model |
Replacement Parts |
List Price |
Sale Price |
| MTL-90B |
SET OF TEST LEADS WITH ALLIGATOR CLIPS |
$16.95 |
| $14.75 |  |
|
| TPK-59 |
THERMOCOUPLE, DUAL BANANA |
$17.95 |
| $15.62 |  |
|
| SV-U |
CASE, UNIVERSAL |
$19.95 |
| $17.36 |  |
|
Specifications
| General |
| TRMS |
YES |
| AC Current |
40.0 / 400.0 / 1000 A |
| AC Current Basic Accuracy |
+/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
| DC Voltage |
600.0V |
| DC Voltage Basic Accuracy |
+/-(0.5% Rdg + 5 LSD) |
| AC Voltage |
600.0V |
| AC Voltage Basic Accuracy |
+/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
| Resistance |
999.9 Ohms |
| Resistance Basic Accuracy |
+/-(1.0% Rdg + 6 LSD) |
| Frequency |
5.00Hz to 500.0Hz |
| Frequency Basic Accuracy |
+/-(0.5% Rdg +4 LSD) |
| Active Power (W) |
0 to 600.0 kW |
| Active Power (W) Basic Accuracy |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
| Reactive Power (VAR) |
0 to 600.0 kVAR |
| Reactive Power (VAR) Basic Accuracy |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
| Apparent Power (VA) |
0 to 600.0 kVA |
| Apparent Power (VA) Basic Accuracy |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
| Power Factor |
0.10 to 0.99 |
| Power Factor Basic Accuracy |
+/- 3 LSD @ Harmonics Fund to 21th |
| Safety |
CAT III 600V |
|