company logo Amprobe AC71B
Automatic AC Clamp Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Amprobe AC71B
Automatic AC Clamp Multimeter




Click image to enlarge

 Amprobe AC71B

Features:
  • AutoTect Function - automatically selects AC volts, DC volts or resistance depending upon measurement point
  • Automatic bright blue backlight turns on when a dark environment is sensed
  • Easy one-button control
  • AC current to 600 A
  • AC volts to 750 V
  • DC volts to 1000 V
  • Resistance and Continuity Beeper
  • Data Hold
  • Conductor size 1.25 in, 32 mm, 750 MCM
Included Accessories:
  • Carrying Case
  • Test Leads
  • Users Manual



  Description

The automatic everything clamp meter

The AC71B is a digital clamp multimeter with two additional unique features: AutoTect and automatic backlight. The Auto- Tect feature automatically senses what type of measurement is being made when the test leads are placed across a measurement point. There is no knob to turn. The meter knows what is being measured and the digital display shows the measured value along with the associated unit icon. AutoTect also utilizes a lower input impedance. This helps determine if voltage is from leakage (called ghost voltages) or a hard connection. Any ghost voltages will be zeroed out by the lower input impedance.

The automatic backlight has a sensor that recognizes when the ambient light becomes dim and turns itself on. A bright blue backlight is then available to easily read the measurement value on the digital display.

The AC71B is a complete multimeter measuring AC and DC volts, resistance, continuity in addition to the AC current. A useful tool for the electrician, plant maintenance, HVAC or field service technician.




  Models, Options, & Accessories


Model Description List Price Sale Price
AC71B AUTOMATIC 600A CLAMPMETER WITH AUTOTECT $125.94
$109.57 
Model Accessories List Price Sale Price
TL36A TEST LEAD SET W/ ALLIGATOR CLIP,CAT III 1KV $12.95
$11.27 



  Specifications

General Specifications
 
Display 6000 digit large scale liquid crystal display (LCD)
Measuring Rate 5 times per second
Overrange Display OL is displayed
Automatic Power Off Time Approximately 30 minutes after power on Low Battery Indication The battery symbol is displayed when the battery voltage drops below the operating level for accurate results.
Power Single standard 9 V battery, NEDA160A
Battery Life 250 hours with an alkaline 9 V battery
Environmental Indoor use
Operating Temperature 0°C to 30°C at ²80 % R.H.
30°C to 40°C at ²75 % R.H.
40°C to 50°C at ²45 % R.H.
Storage Temperature -20°C to 60°C at 0 to 80 % R.H. (battery removed)
Altitude 2000 m (6562 ft)
Conductor Size 32 mm diameter (1.3 in)
Max. Operation Time Delay Time = 30s for input ²30 V
Shock Vibration Sinusoidal vibration per MIL-PRF-28800F (5 to 55 Hz, 3 G maximum)
Agency Approvals CE, cCSAus
Safety Conforms to EN61010-1:2001; CAT II 1000 V, CAT III 600 V, Pollution degree 2, Class 2
EMC Conforms to EN61326-1.
 
Mechanical Specifications
Electrical Specifications ± (% reading + number of digits) at 23 °C ± 5 °C at <80 % R.H.
Temperature Coefficient: add 0.2 x (Specified Accuracy)/°C, < 18 °C, >28 °C
Function Range Accuracy
Voltage
Voltage AC (50 to 500 Hz) 1.3 V to 750.0 V ±(1.5% + 3 dgt)
Voltage DC 1.8 V to 1000.0 V ±(1% + 2 dgt)
  -0.6 V to -1000.0 V ±(1% + 4 dgt)
Overvoltage Protection 1000 V DC/750 V AC  
Input Impedance≥ 4 kW for input voltage up to 30 V. Impedance increases with input voltage to approximate 300 kΩ at 1000 V/277 kΩ at 750 V AC.  
Resistance
Resistance 0.0 Ω to 99.9 Ω ±(2% + 1 Ω)
Continuity 100.0 Ω to 2000 Ω ±(2% + 2 dgt)
Overload Protection 1000 V DC / 750 V RMS  
Maximum Open Circuit Voltage 1.5 V  
Continuity Check
Internal sounds activate if the resistance of the circuit under test is less than 25 W. It will then turn off if the resistance is increased beyond 150 W. Temperature coefficient multiply by 1.5 when operating temperature is 40 °C to 50 °C.
AC Current
AC Current (50 to 60 Hz) 0.0 to 60.0 A ±(1.9% + 2 A)
  60.0 to 400.0 A ±(1.9% + 5 A)
  401 to 500.0 A ±(2.5% + 7 A)
  501 to 600.0 A* ±(3% + 10 A)
Overload Protection 0 to 500 A: Continuous operation  
* 501 A to 600 A: 10 minutes maximum followed by 10 minute cooling period




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.