| General Specifications |
| Display |
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
(OL) or (-OL) is displayed |
| Zero |
Automatic |
| Low Battery Indication |
The Indication is displayed when the battery voltage drops below the operating level |
| Measurement Rate |
2.5 times per second, nominal |
| Operating Environment |
0 °C to 50 °C at <70 % R.H. |
| Storage Temperature |
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter |
| Accuracy |
Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity |
| Temperature Coefficient |
0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C) |
| Altitude |
2000 m (6561.7 ft) |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
200 hours typical with carbon-zinc |
| Dimensions |
(H x W x D) 155 mm x 72 mm x 32 mm (6.1 in x 2.8 in x 1.3 in) |
| Weight |
Approx. 210 g (7.4 oz) including battery |
| Warranty |
One-year |
| Electrical Specifications |
| DC Volts Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V Accuracy: ± (1.0 % rdg + 1 dgt) |
| AC Volts (45 Hz to 500 Hz) Ranges |
200 mV, 2 V, 20 V, 200 V, 750 V Accuracy: ± (1.5 % rdg + 5 dgts) |
| Voltage Resolution |
100 µV |
| Voltage Input Impedance |
10 Mω |
| Overload Protection |
200 mV: 1000 V dc or 750 V ac rms (3 minutes) All other ranges: 1000 V dc or 750 V ac rms |
| DC Current Ranges |
200 µA, 2 mA, 20 mA, 200 mA Accuracy: ± (1.5 % rdg + 1 dgt) |
| AC Current (45 Hz to 500 Hz) Ranges |
200 µA, 2 mA, 20 mA, 200 mA Accuracy: ± (2.0 % rdg + 5 dgts) |
| Current Resolution |
0.1 µA |
| Input Protection |
315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input |
| Burden Voltage |
300 mV max. (1 V max. on 200 mA range) |
| Resistance |
200 ω , 2 kω , 20 kω , 200 kω ± (1.0 % rdg + 4 dgts) |
| Resistance |
2 Mω ± (1.5 % rdg + 4 dgts) |
| Resistance |
20 Mω ± (2.0 % rdg + 5 dgts) |
| Resistance Resolution |
100 mω |
| Open Circuit Voltage |
0.3 V dc typical, (3.0 V dc on 200 ω range) |
| Overload Protection |
1000 V dc or 750 V ac rms |
| Continuity |
Audible Indication: 75 ω ± 25 ω, Response Time: 100 ms |
| Diode Test Current |
1.0 mA (approximate) ±(1.5 % rdg + 3 dgts) |
| Diode Test Resolution |
1 mV |
| Open Circuit Voltage |
3.0 V dc typical |
| Non-Contact Voltage Indicator |
Sense voltage 70 V to 600 V ac; beeper chirps and bright red LED on, works on all ranges |
| Battery Test |
1.5 V, 9 V Accuracy: ± (3.5 % rdg + 2 dgts) |