| General Specifications (Stated accuracy at 23 ºC ±5 ºC, <75 % relative humidity.) |
| Display |
4 ¾ digit liquid crystal display (LCD) with a 41 segment analog bargraphic. |
| Auto ranging |
9999 counts |
| Manual ranging |
9999 counts |
| Polarity |
Automatic, positive implied, negative polarity indication. |
| Overrange |
(OL) or (-OL) is displayed. |
| Zero |
Automatic. |
| Low battery indication |
The indicator is displayed when the battery voltage drops below the operating level. |
| Auto power off |
Approx. 30 minutes. |
| Measurement rate |
2 times per second, nominal. |
| Operating environment |
0 ºC to 50 ºC at <70 % R.H. |
| Storage temperature |
-20 ºC to 60 ºC, 0 to 80 % R.H. with battery removed from meter. |
| Temperature Coefficient |
0.1 x (specified accuracy) per ºC. (0 ºC to 18 ºC, 28 ºC to 50 ºC). |
| Altitude |
(2000 m) 6562 feet |
| Power |
Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. |
| Battery life |
75 hours typical with carbon-zinc. 150 hours typical with alkaline. Using the backlight will decrease battery life. |
| Dimensions |
196 mm (H) x92 mm (W) x60 mm (D). |
| Weight |
with battery and holster, 482 grams |
| Electrical Specifications |
| DC Voltage Ranges |
1000 mV, 10 V, 100 V, 1000 V |
| DC Voltage Accuracy |
all ranges ± (0.1 % rdg + 5 dgt) |
| DC Voltage Resolution |
100 µV |
| AC Voltage (45 Hz to 2 kHz) True RMS Ranges |
1000 mV, 10 V, 100 V, 750 V |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Resolution |
100 µV |
| AC coupled |
True RMS specified from 5 % to 100 % of range |
| DC Current Ranges |
100 µ, 1000 µ, 10 mA, 100 mA, 400 mA, 10 A |
| DC Current Accuracy |
100 µ range: ± (0.5 % rdg + 10 dgt) |
| DC Current Accuracy |
1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts) |
| DC Current Accuracy |
10 A range: ± (1.5 % rdg + 10 dgt) |
| DC Current Resolution |
0.01 µA |
| AC Current (45 Hz to 1 kHz) True RMS Ranges |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy |
100 µ to 100 mA ranges: ± (1.5 % rdg + 10 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy |
400 mA range: ± (2.0 % rdg + 10 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy |
10 A range: ± (2.5 % rdg + 10 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Resolution |
0.01 µA |
| Resistance Ranges |
1000 ω 10 kω 100 kω 1000 kω 10 Mω 40 Mω |
| Resistance Accuracy |
1000 ω to 1000 kω ranges: ± (0.5 % rdg + 8 dgts) |
| Resistance Accuracy |
10 Mω range: ± (1.0 % rdg + 10 dgts) |
| Resistance Accuracy |
40 Mω range: ± (2.0 % rdg + 10 dgts) |
| Logic Test , Logic Type |
TTL, CMOS |