| General Specifications |
| Display |
3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999 |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
(OL) or (-OL) is displayed |
| Zero |
Automatic |
| Low Battery Indication |
The indicator is displayed when the battery voltage drops below the operating level |
| Auto Power Off |
Approx. 10 minutes |
| Measurement Rate |
2 times per second, nominal |
| Operating Environment |
0 °C to 50 °C at <70 % R.H. |
| Storage Temperature |
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter |
| Accuracy |
Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity |
| Temperature Coefficient |
0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 C to 50 °C) |
| Altitude |
2000 m |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
150 hours typical with carbon-zinc, 300 hours typical with alkaline |
| Dimensions |
(H x W x D) 155 mm x 72 mm x 32 mm |
| Weight |
Approx. 400 g including battery |
| Warranty |
One-year |
| Electrical Specifications |
| DC Volts Range |
400 mV, 4 V, 40 V, 400 V, 1000 V |
| AC Volts (45 Hz to 500 Hz) Range |
400 mV (45 Hz to 100 Hz) |
| AC Volts (45 Hz to 500 Hz) Range |
4 V, 40 V, 400 V, 750 V |
| Voltage Resolution |
100 µV |
| Input Impedance |
400 mV: >100 Mω ; 4 V: 10 Mω ; 40 V to 1000 V: 9.1 Mv |
| Overload Protection |
1000 V dc or 750 V ac rms |
| DC Current Range |
400 µA, 4000 µA, 40 mA, 400 mA ± (1.0 % rdg + 2 dgt) |
| DC Current Range |
2 A ± (2.0 % rdg + 3 dgts) |
| AC Current (45 Hz to 500 Hz) Range |
400 µA, 4000 µA, 40 mA, 400 mA ± (1.5 % rdg + 5 dgts) |
| AC Current (45 Hz to 500 Hz) Range |
2 A ± (2.5 % rdg + 5 dgts) |
| Current Resolution |
0.1 µA |
| Input Protection |
2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input |
| Burden Voltage |
500 mV max. (2 V max. on 4 mA, 400 mA ranges) |
| Resistance |
400 ω , 4 kω , 40 kω , 400 kω , 4 Mω ± (1.0 % rdg + 4 dgts) |
| Resistance |
40 Mω ± (2.0 % rdg + 5 dgts) |
| Resistance Resolution |
100 mω |
| Open Circuit Voltage |
-0.45 V dc typical, (-1.2 V dc on 400 ω range) |
| Overload Protection |
1000 V dc or 750 V ac rms |
| Temperature |
400 °C, 1000 °C, 400 °F, 1832 °F Range -20 °C to 10 °C Accuracy ± (2.0 % rdg + 4 °C) Range 10 °C to 200 °C Accuracy ± (1.0 % rdg + 3 °C) Range 200 °C to 1000 °C Accuracy ± (3.0 % rdg + 2 °C) Range -4 °F to 50 °F Accuracy ± (2.0 % rdg + 8 °F) Range 50 °F to 400 °F Accuracy ± (1.0 % rdg + 6 °F) Range 400 °F to 1832 °F Accuracy ± (3.0 % rdg + 4 °F) |
| Resolution |
0.1 °C, 0.1 °F |
| Overload Protection |
1000 V dc or 750 V ac rms |
| Frequency |
Range4 k, 40 k, 400 k, 1 M Accuracy ± (0.1 % rdg + 3 dgts) |
| Resolution |
1 Hz |
| Sensitivity |
10 Hz to 1 MHz: >2.5 V rms |
| Minimum Pulse Width |
> 25 ns |
| Duty Cycle Limits |
> 30 % and < 70 % |
| Overload Protection |
1000 V dc or 750 V ac rms |
| Continuity |
| Audible Indication |
Less than 25 ½ |
| Response Time |
100 ms |
| Overload Protection |
1000 VDC or 750 VAC rms |
| Diode Test |
| Test Current |
Range 1.2 mA (approximate) Accuracy ± (1.5 % rdg + 3 dgts) |
| Resolution |
1 mV |
| Open Circuit Voltage |
3.0 dc typical |
| Overload Protection |
1000 V dc or 750 V ac rms |
| Non-Contact Voltage Indicator |
Sense voltage 70 V to 600 V ac beeper chirps and big bright red LED comes on, works on all ranges |