Features:
- The 15XP-B is the right choice for electronics engineers, technicians and field service
- Autoranging display for faster measurements
- TTL logic test for digital circuits
- Integrated tilt stand for easy bench use
- Diode test for component level troubleshooting
- Data Hold freezes display to “hold” measurement reading
- 750 V AC / 1000 V DC—highest voltage rating in this size of meter
- Special 2000M ? measurement range
- Warranty: One-year
- Battery Life: 200 hours typical with carbon-zinc
- Safety: CAT II 1000V, CATIII 600V, CE, N10140
Included Accessories:
- Pair of test leads (TL245A)
- fuse 2 A/1000 V (P/N FP200)
- 9 V battery (installed)
- Magne-Grip Holster with magnetic hanging strap
- User's manual
|
Description
|
A compact digital multimeter for electronics and test applications. The 15XP-B is the right choice for electronics engineers, technicians, and field service.
|
Models, Options, & Accessories
- VC30 - Vinyl Carrying Case
- DL243C
| Model |
Description |
List Price |
Sale Price |
| 15XP-B |
COMPACT DMM WITH NCV AND LOGIC TEST |
$59.95 |
| $52.16 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| VC30 |
Please call or email us for pricing and availability. |
| DL243C |
Please call or email us for pricing and availability. |
Specifications
| General Specifications |
| 15XP-B Digital Multimeter |
| Display |
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
(OL) or (-OL) is displayed |
| Zero |
Automatic |
| Low Battery Indication |
The ”+” is displayed when the battery voltage drops below the operating level |
| Auto Power Off |
Approx. 10 minutes |
| Measurement Rate |
2 times per second, nominal |
| Operating Environment |
0 °C to 50 °C at <70 % R.H. |
| Storage Temperature |
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter |
| Accuracy |
Stated accuracy at 23 ?C ? 5 ?C, <75 % relative humidity |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
200 hours typical with carbon-zinc |
| Dimensions |
(H x W x D) 155 mm x 72 mm x 32 mm |
| Weight |
Approx. 210 g including battery |
| Warranty |
One-year |
| Electrical Specifications |
| Function |
Range |
Accuracy |
| Voltage |
| DC Volts |
| Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V |
± (0.5 % rdg + 1 dgt) |
| AC Volts (45 Hz to 500 Hz) |
| Ranges |
200 mV (45 Hz to 100 Hz) |
± (1.5 % rdg + 5 dgts) |
| |
2 V, 20 V, 200 V, 750 V |
± (1.5 % rdg + 5 dgts) |
| Resolution |
100 μV |
|
| Input Impedance |
400 mV: >100 MW; 4 V: 10 MW; 40 V to 1000 V: 9.1 MΩ |
|
| Overload Protection |
1000 V DC or 750 V AC RMS |
|
| Current |
| DC Current |
| Ranges |
200 μA, 2000 μA, 20 mA, 200 mA |
± (1.0 % rdg + 2 dgt) |
| |
2 A |
± (2.0 % rdg + 3 dgts) |
| AC Current (45 Hz to 500 Hz) |
| Ranges |
200 μA, 2000 μA, 20 mA, 200 mA |
± (1.5 % rdg + 5 dgts) |
| |
2 A |
± (2.5 % rdg + 5 dgts) |
| Resolution |
0.1 μA |
|
| Input Protection |
2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input |
|
| Burden Voltage |
500 mV max. (2 V max. on 2 mA, 200 mA ranges) |
|
| Resistance |
200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ |
± (1.0 % rdg + 4 dgts) |
| |
2000 MΩ |
± {5.0 % (rdg -10 dgts) +20 dgt} |
| Resolution |
100 mΩ |
|
| Open Circuit Voltage |
-0.45 V DC typical, (-1.2 V DC on 200 Ω range) |
|
| Overload Protection |
1000 V DC or 750 V AC RMS |
|
| Continuity |
| Audible Indication |
Less than 25 Ω |
|
| Response Time |
100 ms |
|
| Overload Protection |
1000 V DC or 750 V AC RMS |
|
| Diode Test |
| Test Current |
1.2 mA (approximate) |
±(1.5 % rdg + 3 dgts) |
| Resolution |
1 mV |
|
| Open Circuit Voltage |
3.0 dc typical |
|
| Overload Protection |
1000 V DC or 750 V AC RMS |
|
| Logic Test |
TTL |
|
| Thresholds Logic 1 (Hi ) |
2.8 V ± 0.8 V |
|
| Thresholds Logic 0 (Lo) |
0.8 V ± 0.5 V |
|
| Test Voltage |
TTL 5 VDC |
|
| Frequency Range |
20 MHz |
|
| Pulse Width |
25 ns min |
|
| Duty Cycle Limits |
> 30 % and < 70 % |
|
| Indication |
40 ms beep at Logic 0 ( Lo) |
|
| Overload Protection |
1000 VDC or 750 VAC RMS |
|
| Non-Contact Voltage Indicator |
| Sense voltage 70 V to 600 V ac (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges |
|