company logo Amprobe 15XP-A
Compact Digital Multimeter
with NCV & Logic Test
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Amprobe 15XP-A
Compact Digital Multimeter
with NCV & Logic Test




Click image to enlarge

Amprobe 15XPA




Click image to enlarge

Features:
  • 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
  • Automatic, positive implied, negative polarity indication
  • (OL) or (-OL) is displayed
  • Low Battery Indication
  • Auto Power Off : Approx. 10 minutes
  • Measurement Rate 2 times per second, nominal
  • Operating Environment 0 °C to 50 °C at <70 % R.H.
  • Storage Temperature -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
  • Accuracy Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
  • Temperature Coefficient 0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
  • Altitude 2000 m
  • Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22

Included Accessories:
  • Pair of test leads (TL245A)
  • fuse 2 A/1000 V (P/N FP200)
  • 9 V battery (installed)
  • Magne-Grip Holster with magnetic hanging strap
  • User's manual



  Description

A compact digital multimeter for electronics andtest applications. The 15XP-A is the right choice for electronics engineers, technicians, and field service.



  Models, Options, & Accessories

  • VC30 - Vinyl Carrying Case
  • DL243C


Model Description List Price Sale Price
15XP-A COMPACT DMM WITH NCV AND LOGIC TEST $62.95
$54.77 
Model Accessories List Price Sale Price
VC30 Please call or email us for pricing and availability.
DL243C Please call or email us for pricing and availability.



  Specifications

General Specifications
15XP-A Digital Multimeter
Display 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Zero Automatic
Low Battery Indication The "battery symbol" is displayed when the battery voltage drops below the operating level
Auto Power Off Approx. 10 minutes
Measurement Rate 2 times per second, nominal
Operating Environment 0 ?C to 50 ?C at <70 % R.H.
Storage Temperature -20 ?C to 60 ?C, 0 to 80 % R.H. with battery removed from meter
Accuracy Stated accuracy at 23 ?C ? 5 ?C, <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per ?C (0 ?C to 18 ?C, 28 ?C to 50 ?C)
Altitude 2000 m
Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 200 hours typical with carbon-zinc
Dimensions (H x W x D) 155 mm x 72 mm x 32 mm
Weight Approx. 210 g including battery
Warranty One-year

Electrical Specifications
Function Range Accuracy
Voltage
DC Volts
Ranges 200 mV, 2 V, 20 V, 200 V, 1000 V ± (0.5 % rdg + 1 dgt)
AC Volts (45 Hz to 500 Hz)
Ranges 200 mV (45 Hz to 100 Hz) ± (1.5 % rdg + 5 dgts)
  2 V, 20 V, 200 V, 750 V ± (1.5 % rdg + 5 dgts)
Resolution 100 μV  
Input Impedance 400 mV: >100 MW; 4 V: 10 MW; 40 V to 1000 V: 9.1 MΩ  
Overload Protection 1000 V DC or 750 V AC RMS  
Current
DC Current
Ranges 200 μA, 2000 μA, 20 mA, 200 mA ± (1.0 % rdg + 2 dgt)
  2 A ± (2.0 % rdg + 3 dgts)
AC Current (45 Hz to 500 Hz)
Ranges 200 μA, 2000 μA, 20 mA, 200 mA ± (1.5 % rdg + 5 dgts)
  2 A ± (2.5 % rdg + 5 dgts)
Resolution 0.1 μA  
Input Protection 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input  
Burden Voltage 500 mV max. (2 V max. on 2 mA, 200 mA ranges)  
Resistance 200 W, 2 kW, 20 kW, 200 kW, 2 MΩ ± (1.0 % rdg + 4 dgts)
  2000 MΩ ± {5.0 % (rdg -10 dgts) +20 dgt}
Resolution 100 mΩ  
Open Circuit Voltage -0.45 V DC typical, (-1.2 V DC on 200 Ω range)  
Overload Protection 1000 V DC or 750 V AC RMS  
Continuity
Audible Indication Less than 25 Ω  
Response Time 100 ms  
Overload Protection 1000 V DC or 750 V AC RMS  
Diode Test
Test Current 1.2 mA (approximate) ±(1.5 % rdg + 3 dgts)
Resolution 1 mV  
Open Circuit Voltage 3.0 dc typical  
Overload Protection 1000 V DC or 750 V AC RMS  
Logic Test TTL  
Thresholds Logic 1 (Hi ) 2.8 V ± 0.8 V  
Thresholds Logic 0 (Lo) 0.8 V ± 0.5 V  
Test Voltage TTL 5 VDC  
Frequency Range 20 MHz  
Pulse Width 25 ns min  
Duty Cycle Limits > 30 % and < 70 %  
Indication 40 ms beep at Logic 0 ( Lo)  
Overload Protection 1000 VDC or 750 VAC RMS  
Non-Contact Voltage Indicator
Sense voltage 70 V to 600 V ac (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET