Our agents are available:
9:00 AM - 6:00 PM EST
Altek 942-BNC Frequency Calibrator with Totalizer and BNC Connector
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   




Altek 942-BNC Frequency Calibrator with Totalizer and BNC Connector



Altek 942-BNC
Click image to enlarge

 Altek 942-BNC


Additional Photos
Click image to enlarge

Features:
  • Laboratory Accurate — ±0.001% of setting (10 PPM).
  • Six Real World Ranges — 1 to 20000 Counts-Per-Hour (CPH), 0.1 to 2000.0 Counts-Per-Minute (CPM), 0.01 to 999.99 Hz, 0.001 to 99.999 kHz and 0.01 to 250.00 kHz.
  • Calibrate Totalizers — Output a selectable number of pulses over 1 to 99 minutes to verify totalizer readings. The calibrator automatically stops outputting when the selected number of pulses has been sent to the totalizer.
  • Count Pulses — Use as a timed totalizer to check flowmeter and integrator outputs. Built-in totalizer to 99999 counts with optional timed operation to 99 minutes up to maximum rate of 100 Hz.
  • Save Time — Calibrate flowmeters, frequency transmitters and integrators. Use CPH and CPM ranges to directly display extremely slow signals, eliminating waiting with stop watch and calculator.
  • Match Your Receiver's Input — Select from sine, zero crossing square or zero based square wave output. Adjustable amplitude from 50 mV to 12 V p-p.
  • Reads All Waveforms — From 40 mV to 240 V peak. Instantly recall the minimum and maximum frequency measured.
  • Quik-Chek Switch — Instantly recall 18 output frequencies (three for each range). Fast, easy adjustment with a multi-speed digital potentiometer.
  • Built-In Leads — Large alligator clips for easy connections. Optional BNC connector available.
  • Long Battery Life — Six AA alkaline batteries last over 40 hours.
  • A Male BNC is added to the top of the calibrator in addition to the attached leads.



  Description

Calibrate your turbine meters, frequency counters, vibration systems, tachometers, vortex shedders, integrators and any other frequency devices in the shop, plant or field. Measure from 0.01 Hz to 250.00 KHz with resolution down to 0.01Hz. For your slower signals, source or measure from 0.1 to 2000.0 counts per minute (CPM) or from 10 to 20000 counts per hour (CPH). Quickly indicate process signals, no more waiting around with stopwatch and calculator.

Use in the field to check the signals from your flowmeter pickups, velocity and motion detectors, Frequencies can be directly measured from 0.01 Hz to 250.00 KHz in four frequency ranges.

Measure extremely slow frequencies (less than 1 Hz) with high resolution using CPM & CPH. Instead of displaying 1/2 Hz as 0.5 Hz (1 digit of resolution) as most with frequency counters you can display it as 30.0 CPM (3 digits of resolution) or as 1800 CPH (4 digits of resolution). You can now measure these slow signals in seconds with the Model 942 instead of many minutes needed with a totalizer, stopwatch and calculator. Measure signals from 30 mV to 40 V peak-topeak with a minimum pulse width of 2 microseconds.

Select sine wave outputs to simulate vibration pickups, variable speed drives and square waves to simulate flowmeters and magnetic pickups. Any frequency from 0.01 Hz to 250.00 KHz can be sourced in four frequency ranges to calibrate tachometers, counters, data loggers, turbine meters and frequency transmitters. For low frequency applications such as positive displacement flowmeters, Watt-hour meters, slow rate integrators and assembly line counting, the Model 942 sources signals as low as 1 CPH (0.0002777 Hz). Amplitude is adjustable from 50 millivolts to 12 volts peak-to-peak.

Calibrate your totalizers & integrators faster and more accurately with the Model 942. Verify totalizer readings by outputting a number of pulses over1 to 99 minutes. The Model 942 will automatically stop when the selected number of pulses have been sent to the totalizer. This eliminates waiting several minutes with a stopwatch to try to catch the total.





  Models, Options, & Accessories


Model Description List Price Sale Price
942-BNC Frequency Calibrator & BNC, Item # 942-BNC $1259.00
$1120.51 
ALTEK942 Please call or email us for pricing and availability.
Model Accessories List Price Sale Price
5501E 90 Y Contact Module, Item # 5501E $419.44
$373.30 



  Specifications

Read  
Accuracy: ±(0.001% of reading + 1 LSD)
Sensitivity: Triggers on positive peaks down to 40 mV peak, DC coupled
Maximum Usable Input Voltage: Less than 40 V peak
Minimum Pulse Width: 2 microseconds
Minimum Time Between Pulses: 2 microseconds
Totalizer: Incremental counter to 99999 counts, timed operation from 1 to 99 minutes at a maximum rate of 1666.65 Hz
Input Impedance: Greater than 1 Meg Ohm + 60pF
Trigger Level Adjustment: x1 & x10 Attenuator plus logarithmic control
Source  
Accuracy: ±0.001% of reading
Waveforms: Sine, zero based square, & zero centered square waves
Totalizer Output: From 1 to 99999 pulses for a period from 1 to 99 minutes up to a maximum rate of 1666.65 Hz
Output Amplitude: 50 mV to 12 V p-p, 50% ±1% duty cycle
Risetime: Less than 1 microsecond @ 12 V pak-to-peak
Output Impedance: 600 Ohms
Source Current: 8 mA maximum
Short Circuit Duration: Infinite
Voltage Protection: Protected against misconnection to 240 Volts peak AC/DC without fuses for 30 seconds
General  
Frequency Stability: Less than 10PPM/year drift
Temperature Effect: ±0.001%/°C based on 23°C
Batteries: Six "AA" batteries (Alkaline supplied and recommended)
Battery Life: Read: >80 hours, nominal
Source: >50 hours, nominal at 250 KHz at 12V p-p
Low Battery: "BAT" indication on the display at 6.5 V nominal, approximate 10 hours left
Attenuator: Logarithmic for smooth input/output signal level control
Operating Temperature Range: -5 to +140°F (-20 to +60°C)
Storage Temperature Range: -13 to +149°F (-25 to +65°C)
Relative Humidity: 10 to 90%, non-condensing, for 24 hours
Warmup Time: 5 seconds to rated accuracy
Dimensions: 183mm x 102mm x 62mm
Weight: 1lb 7oz (0.650kg)
Accessories: A male BNC is added to the top of the calibrator in addition to the attached leads. Carrying Case



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  