Our agents are available:
9:00 AM - 6:00 PM EST
Altek 434-KP Milliamp Calibrator
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   




Altek 434-KP Milliamp Calibrator



Altek 434-KP
Click image to enlarge

 Altek 434-KP

Features:
  • Calibrate with laboratory accuracy ±(0.015% of reading + 0.002 mA); Accurate to 0.005 mA from 4 to 20 mA
  • All 4 to 20 mA loop functions; Source and read milliamps; Simulate 2-wire transmitters; Power transmitters & displays transmitter output; Measure voltage from -100.0 to +100.0V DC
  • Full range 1 microamp resolution; 0.000 to 24.000 mA and -25.00 to 125.00% of 4 to 20 mA
  • Powers loop or transmitter; Drives to 1200 ohm loads – enough for any transmitter or loop
  • Standard “AA” alkaline batteries; Over 30 hours of full 20 mA output. Auto-Off saves batteries.
  • User settable “Quik-Chek© ”; Store HI, SET & LO for instant recall
  • “Auto-Chek™” output; Automatically switches output in 2, 3, 5 or 10 steps; Automatic Ramp and Soak to simulate a process
  • “Valve-Chek®” output; Checks valve and actuator closing and opening
  • HART compatibility option (built-in)
Additional Photos
Click image to enlarge




  Description

Calibrate and troubleshoot all the signals in a standard 4 to 20 milliamp process control loop with Altek’s Model 434-KP Milliamp Calibrator. A 24 mA Source, mA meter, 2-wire transmitter simulator and a DC volt meter in one compact unit enables a single tool to perform most calibration and troubleshooting functions.

Calibrate controllers, recorders or other devices in 4 to 20 or 0 to 20 mA loops. Six “AA” batteries provide hours of continuous use. The batteries last several time longer than calibrators with a single 9V battery! Optional AC adapter for continuous use.

Check out the response of a loop by using the Model 434-KP in place of a 2-wire transmitter. The Model 434-KP modulates the current passing through the loop just like a transmitter, but with manual control.

Simultaneously supply power to a 2-wire transmitter while displaying the 4-20 mA output signal. The Model 434-KP supplies a nominal 24 Volts DC to the 2-wire transmitter while displaying the transmitter’s output.

Check 24 Volt loop supplies and batteries using the built-in voltmeter. Verify instruments with 1-5 Volt outputs.

Save time with every calibration by using the advanced features of the Model 434-KP. Instantly recall any three output settings with the handy QUIK-CHEK switch. All output settings are remembered, even with the power off.

Be in two places at once by using the Model 434-KP’s AUTO-CHEK. Connect behind the panel or replace a transmitter, then check the output in front of the panel or another remote location within the loop. Choose 2, 3, 5 or 10 output steps from 5 to 900 seconds to match your calibration setup. Use the automatic Ramp/Soak to simulate a running process and check valves for smooth operation.

Check valve and actuator operation with the built-in Valve-Chek function. Automatically step up & down to check valves at and around the fully closed position and the fully open position. Or manually step through the points and use the Up/Down push-buttons for fine adjustment.





  Models, Options, & Accessories


Model Description List Price Sale Price
434-KP Process Loop Calibrator, Item # 434-KP - Discontinued - replaced by Altek 434
434E Process Loop Calibrator, Item # 434E $939.00
$835.71 



  Specifications

Milliamp Source  
Ranges: 0.000 to 24.000mA with 1 microamp resolution
-25.00 to 125.00% of 4-20mA with 0.01% resolution
Typical Drive Capability: 1200 Ohms @ 20.00 mA
Power to Drive Receiver: Nominal 24 VDC
Compliance Voltage: 0 to 500 Ohm Load: 12 V nominal @ 20.000 mA
500 to 1200 Ohm load: 24 V nominal @ 20.000 mA
Power & Measure 2-wire Transmitters  
Ranges: 0.000 to 24.000mA with 1 microamp resolution
-25.00 to 125.00% of 4-20mA with 0.01% resolution
Output Current: Up to 24.000 mA
Typical Drive Capability: 1200 Ohms @ 20.00 mA
Power to External 2-wire transmitter: Nominal 24 VDC
Read Milliamps  
Ranges: 0.000 to 24.000mA with 1 microamp resolution
-25.00 to 125.00% of 4-20mA with 0.01% resolution
Voltage Burden: 0.9V at 4 mA, 1.2V at 20 mA, 1.4V at 24 mA
Read Transmitter Test Jecks or Accross Loop Diodes  
Ranges: 0.000 to 24.000mA with 1 microamp resolution
-25.00 to 125.00% of 4-20mA with 0.01% resolution
Overvoltage Protection: Fuse, 5 x 20 mm, 250 mA, 250V
Input Impedance: 15 Ohms
Simulate 2-wire Transmitters  
Ranges: 1.000 to 24.000 mA
Loop Voltage Limits: Minimum: 2 VDC
Maximum: 50 VDC
Measure DC Volts  
Range: -100.0 to +100.0 DC Volts
Accuracy: ±0.5% of Full Scale Reading from 0.0 to 100.0V
Input Resistance: > 1 Meg Ohm
Source Resistance Effect: 0.01% per 100 Ohms
General  
Milliamp Accuracy: ±(0.015% of Reading + 0.002 mA)
Temperature Effect: ±0.008%/°C based on 23°C ±25°C
Batteries: Six "AA" batteries (Alkaline supplied and recommended)
Battery Life: Milliamp Source and 2-wire Modes: Nominal 44 hours at 12 mA, 30 hours at 20 mA with 250 ohm load
Other Functions: Nominal 75 hours
AC Adapters: Optional, 120 or 240 VAC, 50/60 Hz
Low Battery Indication: "BAT" indication on the display at 6.5 V nominal, approximately 4 hours left
Operating Temperature Range: -5 to +130 °F (-20 to +55°C)
Storage Temperature Range: -13 to +130 °F (-25 to +55°C)
Relative Humidity: 10 to 90%, non-condensing for 24 hours
Warm up Time: 10 seconds to rated accuracy, 2 minutes to full accuracy
Dimensions: 158.1mm (6.23 in) x 83.1mm (3.27 in) x 49.3mm (1.94 in)
Weight: 1lb 2oz (0.5kg)



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET