Altek 334A Loop Calibrator
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   




Altek 334A Loop Calibrator



Altek 4353E
Click image to enlarge

 Altek 4353E

Features:
  • All 4 to 20 mA Loop Functions — Source 0.00 to 24.00 mA or -25.0 to 125.0% read mA or percent to 52.00 mA, simulate 2-wire transmitters, measure -99.99 to 99.99 volts DC power & read 2-wire transmitters.
  • Quik-Chek Switch — Select 4 or 20 mA output or 2-wire simulation. Accurate to ±0.006 mA.
  • Full Range 10 Microamp Resolution — Adjust 4 digit display to ±0.05% without range change.
  • Long Battery Life — 3x9 volt alkaline batteries source 20 mA for over 20 hours, 12 mA for over 33 hours; 2-wire simulate and read for 150 hours. Much longer than NiCd batteries or calibrators with a single 9 V battery!
  • Drive Capability — 1200 Ohms with current limited, fuseless protection to 135 V AC/DC.
Additional Photos
Click image to enlarge




For a better alternative see the PIE 334 or the PIE 334Plus




  Description

The Altek Model 334A will check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp DC loop. Use at every point in your loop. Source & Read 0.00 to 24.00 mA, Simulate a 2-wire transmitter or use the Model 334A to simultaneously power & measure your 2-wire transmitters. Toggle the display to show milliamps or percent of 4 to 20.

Calibrate recorders, digital indicators, stroke valves or any other instruments that get their input from a 4 to 20 mA loop. Easily set any value to within 0.01 mA with the speed sensitive digital potentiometer.

The “Quik-Chek” switch provides rapid checking of 4.00, 20.00 and a third point between 0.00 to 24.00 mA.

Check loop wiring and receivers by using the Model 334A in place of a 2-wire transmitter. Simulate a changing process input to check loop response and control settings. The Model 334A uses any loop power from 3 to 45V DC.

Check controller outputs or measure the milliamp signal anywhere in the loop. The Model 334A measures 0.00 to 24.00 mA signals with much greater accuracy than a typical multimeter. Toggle the display to show milliamps or percent of 4 to 20.

Simultaneously measure the output of a 2-wire transmitter while using the internal batteries to supply up to 27V DC to power the transmitter. Handy for checking transmitters in the field or on the bench.

Measure from -99.99 to 99.99 VDC with 10mV resolution. Use it to check loop power supplies, I/V converters, 1 to 5 Volt signals and battery voltages.





  Models, Options, & Accessories


Model Description List Price Sale Price
4353E Calibrator 4 to 20 mA, Item # 4353E $738.00
$656.82 

Be Sure to check out the Martel LC-100 as a reasonable alternative.



  Specifications

Milliamp Source  
Ranges: 0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20 mA
Accuracy: Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD)
Typical Drive Capability: 1200 Ohms @ 20.00 mA with fresh batteries, 800 Ohms @ 20.00 mA with low batteries
Compliance: Nominal 27 VDC @ 20 mA with fresh batteries
Power & Measure 2-wire Transmitters  
Ranges: 0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20 mA
Accuracy: Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD)
Output Current: Up to 24.00 mA
Typical Drive Capability: 1200 Ohms @ 20.00 mA with fresh batteries, 800 Ohms @ 20.00 mA with low batteries
Compliance: Nominal 27 VDC @ 20 mA with fresh batteries
2-wire Transmitter Simulator  
Ranges: 0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20 mA
Accuracy: Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD)
Loop Voltage Limits: Minimum: 2 VDC
Maximum: 100 VDC
Overload Protection: Current limited to 25 mA nominal
Milliamp Read  
Ranges: 0.00 to 52.00 mA; -25.0 to 300.0 % of 4 to 20 mA
Accuracy: Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD)
Voltage Burden: 0.9V at 4 mA, 1.2V at 20 mA, 1.9V at 50 mA excitation current
Read DC Volts  
Range: -99.99 to 99.99V DC
Input Impedance: >2 Meg Ohms
General  
Accuracy: Quik-Chek 4 & 20 mA ±(0.03% of Setting + 1 LSD)
Milliamp & % Ranges ±(0.05% of Reading + 1 LSD)
Read DC Volts ±(0.05% of Span + 1 LSD)
Warm up Time: 10 Seconds to specified accuracy, 2 minutes to maximum accuracy
Temperature Effect: Milliamp Ranges: ±0.008% of Reading/°C
Read DC Volts: ±0.012% of Span/°C
Batteries: Three 9V, (1604) batteries (Alkaline supplied and recommended)
Battery Life: Source and Power Transmitter: Nominal 33 hours at 12 mA, 20 hours at 20 mA with 250 ohm load
Read mA, DC V & 2-wire Simulate: Nominal 100 hours
Low Battery Indication: "BAT" indication on the display at approximately 4 hours left
Overvoltage Protection: Protected to 135V AC/DC for 30 seconds without fuses
Operating Temperature Range: -5 to +140 °F (-20 to +60°C)
Storage Temperature Range: -22 to +160 °F (-30 to +70°C)
Relative Humidity: 10 to 90%, non-condensing for 24 hours from 0 to 35°C
Dimensions: 121.9mm (4.8 in) x 66mm (2.6 in) x 35.8mm (1.41 in)
Weight: 7.8oz (0.22kg)



   