| Features |
E363XA |
E364XA |
661XC |
663XB |
664XA |
| No. of Models |
4 |
10 |
4 |
4 |
5 |
| Delivery |
< 1 week, typically |
< 1 week, typically |
1 week |
1 week |
1 week |
| No. of Outputs |
1 or 3 |
1 or 2 |
1 |
1 |
1 |
| Applications |
Semi-automated general purpose bench testing |
Moderate speed semi-automated and automated production test |
High performance automated production test |
High performance automated production test |
High performance automated production test |
| Size |
Half rack, 3U |
Half rack, 2U/3U |
Half rack, 2U |
Full rack, 2U |
Full Rack, 2U |
| Connections |
E3631/2A, Front only E3633/4A, Front & rear |
Front & rear |
Rear only |
Rear only |
Rear only |
| Programming |
GPIB and RS-232 |
GPIB and RS-232 |
GPIB and RS-232 |
GPIB and RS-232 |
GPIB only |
| Programmable Wakeup State |
No |
No |
Yes |
Yes |
Yes |
| Throughput Capabilities |
| Output rise/fall |
130 to 550 ms |
<90 ms |
6 ms |
6 ms |
35 ms |
| Transient Response |
<50µs for output to recover within 15mV following a change in output current |
<50µs for output to recover within 15mV following a change in output current |
=100µs (50µs in the fast mode) for output voltage to recover from zero to full load within 20mV |
=100µs (50µs in the fast mode) for output voltage to recover from zero to full load within 20mV |
=100µs for output voltage to recover from zero to full load within 20mV |
| DFI/RI |
Relay control available from pin 1 of RS-232 connector |
Relay control available from pin 1 of RS-232 connector |
Allows shut down of multiple supplies or other h/w, provides for output relay control |
Allows shut down of multiple supplies or other h/w, provides for output relay control |
Allows shut down of multiple supplies or other h/w, provides for output relay control |
| Active Down programmer |
No |
No |
Yes |
Yes, negative current is programmable |
Yes, sinks 20% of rated output current |
| Performance |
| Ripple and Noise (20 Hz to 20 MHz) |
2 - 3mVpp/ 0.35 - 0.5mVrms |
<5mVpp/0.5mVrms for 8V/20V models
<8mVpp/1mVrms for 35V/60V models |
3mVpp/0.3mVrms for 8V/20V models
3mVpp/0.5mVrms for 50V model
3mVpp/0.5mVrms for 100V model |
3mVpp/0.3mVrms for 8V/20V models
3mVpp/0.5mVrms for 50V model
3mVpp/0.5mVrms for 100V model |
3mVpp/300mVrms for 8V/20V models
4mVpp/400mVrms for 35V model
5mVpp/500mVrms for 60V model
7mVpp/700mVrms for 120V model |
| Line/Load Regulation |
Voltage < 0.01% + 2mV Current < 0.01% + 250mA |
Voltage <0.01% + 3mV Current <0.01% + 250mA |
Voltage 0.5mV - 5 mV Current 0.25mA - 1mA |
Voltage 0.5mV - 5 mV Current 0.25mA - 1mA |
Voltage 0.5mV - 5 mV Current 0.25mA - 1mA |
| Remote Sensing |
Can drop up to 0.7V in each load lead E3631A, None |
Can drop up to 1V in each load lead |
Can drop up to 2V in each load lead |
Can drop up to 2V in each load lead |
Can drop up to 2V in each load lead |
| Meters |
4 or 5 digit voltage/ 4 digit current |
4 digit |
4 digit |
4 digit |
4 digit |