Our agents are available:
9:00 AM - 6:00 PM EST
Agilent 30W to 200W Low Power DC Power Supplies Comparison Guide
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Agilent 30W to 200W Low Power DC Power Supplies Comparison Guide


Features E363XA E364XA 661XC 663XB 664XA
No. of Models 4 10 4 4 5
Delivery < 1 week, typically < 1 week, typically 1 week 1 week 1 week
No. of Outputs 1 or 3 1 or 2 1 1 1
Applications Semi-automated general purpose bench testing Moderate speed semi-automated and automated production test High performance automated production test High performance automated production test High performance automated production test
Size Half rack, 3U Half rack, 2U/3U Half rack, 2U Full rack, 2U Full Rack, 2U
Connections E3631/2A, Front only E3633/4A, Front & rear Front & rear Rear only Rear only Rear only
Programming GPIB and RS-232 GPIB and RS-232 GPIB and RS-232 GPIB and RS-232 GPIB only
Programmable Wakeup State No No Yes Yes Yes
Throughput Capabilities
Output rise/fall 130 to 550 ms <90 ms 6 ms 6 ms 35 ms
Transient Response <50µs for output to recover within 15mV following a change in output current <50µs for output to recover within 15mV following a change in output current =100µs (50µs in the fast mode) for output voltage to recover from zero to full load within 20mV =100µs (50µs in the fast mode) for output voltage to recover from zero to full load within 20mV =100µs for output voltage to recover from zero to full load within 20mV
DFI/RI Relay control available from pin 1 of RS-232 connector Relay control available from pin 1 of RS-232 connector Allows shut down of multiple supplies or other h/w, provides for output relay control Allows shut down of multiple supplies or other h/w, provides for output relay control Allows shut down of multiple supplies or other h/w, provides for output relay control
Active Down programmer No No Yes Yes, negative current is programmable Yes, sinks 20% of rated output current
Performance
Ripple and Noise (20 Hz to 20 MHz) 2 - 3mVpp/
0.35 - 0.5mVrms
<5mVpp/0.5mVrms for 8V/20V models

<8mVpp/1mVrms for 35V/60V models
3mVpp/0.3mVrms for 8V/20V models

3mVpp/0.5mVrms for 50V model

3mVpp/0.5mVrms for 100V model
3mVpp/0.3mVrms for 8V/20V models

3mVpp/0.5mVrms for 50V model

3mVpp/0.5mVrms for 100V model
3mVpp/300mVrms for 8V/20V models

4mVpp/400mVrms for 35V model

5mVpp/500mVrms for 60V model

7mVpp/700mVrms for 120V model
Line/Load Regulation Voltage < 0.01% + 2mV Current < 0.01% + 250mA Voltage <0.01% + 3mV Current
<0.01% + 250mA
Voltage 0.5mV - 5 mV Current 0.25mA - 1mA Voltage 0.5mV - 5 mV Current 0.25mA - 1mA Voltage 0.5mV - 5 mV Current 0.25mA - 1mA
Remote Sensing Can drop up to 0.7V in each load lead E3631A, None Can drop up to 1V in each load lead Can drop up to 2V in each load lead Can drop up to 2V in each load lead Can drop up to 2V in each load lead
Meters 4 or 5 digit voltage/ 4 digit current 4 digit 4 digit 4 digit 4 digit



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET