Features:

  • Fast measurement speed, up to 1000 corrected readings per second, via the GPIB
  • Wide dynamic range
  • Calibration factors, linearity, temperature and bandwidth correction stored in EEPROM
  • Precision type-N connector as standard
Warranty
1 year standard warranty



  Description

The Agilent E9325A peak and average power sensor, 50 MHz to 18 GHz, 300 kHz bandwidth is used with the EPM-P series power meters and E9288A-C sensor cables. The E9325A power sensor is ideal for time-gated peak, average and peak-to-average ratio power measurements on TDMA wireless formats such as NADC, GSM and EDGE.



  Models, Options, & Accessories


Model Description List Price Sale Price
E9321A Peak and Average Power Sensor, 50 MHz to 6 GHz, 300 kHz bandwidth
$1653.00 
E9322A Peak and Average Power Sensor, 50 MHz to 6 GHz, 1.5 MHz bandwidth
$2211.00 
E9323A Peak and Average Power Sensor, 50 MHz to 6 GHz, 5 MHz bandwidth
$3041.00 
E9325A Peak and Average Power Sensor, 50 MHz to 18 GHz, 300 kHz bandwidth
$1994.00 
E9326A Peak and Average Power Sensor, 50 MHz to 18 GHz, 1.5 MHz bandwidth
$2650.00 
E9327A Peak and Average Power Sensor, 50 MHz to 18 GHz, 5 MHz bandwidth
$3536.00 
Model Options List Price Sale Price
E9325A-A6J ANSI Z540 compliant calibration with test data
$239.00 



  Specifications

Sensor model Video bandwidth Frequency range Power range Maximum power Connector type
Average only mode Normal mode1
E9321A 300 kHz 50 MHz to 6 GHz -65 dBm to +20 dBm -50 dBm to +20 dBm +23 dBm average;
+30 dBm peak
(< 10 μsec duration)
Type N (m)
E9325A 50 MHz to 18 GHz
E9322A 1.5 MHz 50 MHz to 6 GHz -60 dBm to +20 dBm -45 dBm to +20 dBm
E9326A 50 MHz to 18 GHz
E9323A 5 MHz 50 MHz to 6 GHz -60 dBm to +20 dBm -40 dBm to +20 dBm
E9327A 50 MHz to 18 GHz
  1. For average power measurements, free run acquisition.
  Lower and upper measurement ranges

  E9321A/E9325A E9322A/E9326A E9323A/E9327A
  Normal Average only Normal Average only Normal Average only
Lower range
(min. power)
-50 dBm -65 dBm -45 dBm -60 dBm -40 dBm -60 dBm
Lower range
(max. power)
Lower to upper auto range point
+0.5 dBm -17.5 dBm1 -5 dBm -13.5 dBm1 -5 dBm -10.5 dBm1
Upper to lower auto range point -9.5 dBm -18.5 dBm -15 dBm -14.5 dBm -15 dBm -11.5 dBm
Upper range
(min. power)
-35 dBm -50 dBm -35 dBm -45 dBm -30 dBm -35 dBm
Upper range
(max. power)
+20 dBm +20 dBm1 +20 dBm +20 dBm1 +20 dBm +20 dBm1
  1. Applies to CW and constant amplitude signals only above –20 dBm.




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.