Agilent E9323A Peak and Average Power Sensor

Click image to enlarge
Agilent E9323A
|
|
Features:
- Fast measurement speed, up to 1000 corrected readings per second, via the GPIB
- Wide dynamic range
- Calibration factors, linearity, temperature and bandwidth correction stored in EEPROM
- Precision type-N connector as standard
Warranty
1 year standard warranty
|
Description
|
The Agilent E9323A peak and average power sensor, 50 MHz to 6 GHz, 5 MHz bandwidth, is used with the EPM-P series power meters and E9288A-C sensor cables. The E9323A power sensor is ideal for time-gated peak, average and peak-to-average ratio power measurements on W-CDMA wireless formats such as cdma2000.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| E9321A |
Peak and Average Power Sensor, 50 MHz to 6 GHz, 300 kHz bandwidth |
| $1650.00 |  |
|
| E9322A |
Peak and Average Power Sensor, 50 MHz to 6 GHz, 1.5 MHz bandwidth |
| $2206.00 |  |
|
| E9323A |
Peak and Average Power Sensor, 50 MHz to 6 GHz, 5 MHz bandwidth |
| $3036.00 |  |
|
| E9325A |
Peak and Average Power Sensor, 50 MHz to 18 GHz, 300 kHz bandwidth |
| $1990.00 |  |
|
| E9326A |
Peak and Average Power Sensor, 50 MHz to 18 GHz, 1.5 MHz bandwidth |
| $2645.00 |  |
|
| E9327A |
Peak and Average Power Sensor, 50 MHz to 18 GHz, 5 MHz bandwidth |
| $3529.00 |  |
|
| Model |
Options |
List Price |
Sale Price |
| E9323A-A6J |
ANSI Z540 compliant calibration with test data |
| $317.00 |  |
|
Specifications
| Sensor model |
Video bandwidth |
Frequency range |
Power range |
Maximum power |
Connector type |
| Average only mode |
Normal mode1 |
| E9321A |
300 kHz |
50 MHz to 6 GHz |
-65 dBm to +20 dBm |
-50 dBm to +20 dBm |
+23 dBm average; +30 dBm peak (< 10 μsec duration) |
Type N (m) |
| E9325A |
50 MHz to 18 GHz |
| E9322A |
1.5 MHz |
50 MHz to 6 GHz |
-60 dBm to +20 dBm |
-45 dBm to +20 dBm |
| E9326A |
50 MHz to 18 GHz |
| E9323A |
5 MHz |
50 MHz to 6 GHz |
-60 dBm to +20 dBm |
-40 dBm to +20 dBm |
| E9327A |
50 MHz to 18 GHz |
- For average power measurements, free run acquisition.
Lower and upper measurement ranges
| |
E9321A/E9325A |
E9322A/E9326A |
E9323A/E9327A |
| |
Normal |
Average only |
Normal |
Average only |
Normal |
Average only |
Lower range (min. power) |
-50 dBm |
-65 dBm |
-45 dBm |
-60 dBm |
-40 dBm |
-60 dBm |
Lower range (max. power) Lower to upper auto range point |
+0.5 dBm |
-17.5 dBm1 |
-5 dBm |
-13.5 dBm1 |
-5 dBm |
-10.5 dBm1 |
| Upper to lower auto range point |
-9.5 dBm |
-18.5 dBm |
-15 dBm |
-14.5 dBm |
-15 dBm |
-11.5 dBm |
Upper range (min. power) |
-35 dBm |
-50 dBm |
-35 dBm |
-45 dBm |
-30 dBm |
-35 dBm |
Upper range (max. power) |
+20 dBm |
+20 dBm1 |
+20 dBm |
+20 dBm1 |
+20 dBm |
+20 dBm1 |
- Applies to CW and constant amplitude signals only above –20 dBm.
|