Agilent E9323A
Peak and Average Power Sensor




Click image to enlarge

 Agilent E9323A

Features:

  • Fast measurement speed, up to 1000 corrected readings per second, via the GPIB
  • Wide dynamic range
  • Calibration factors, linearity, temperature and bandwidth correction stored in EEPROM
  • Precision type-N connector as standard
Warranty
1 year standard warranty



  Description

The Agilent E9323A peak and average power sensor, 50 MHz to 6 GHz, 5 MHz bandwidth, is used with the EPM-P series power meters and E9288A-C sensor cables. The E9323A power sensor is ideal for time-gated peak, average and peak-to-average ratio power measurements on W-CDMA wireless formats such as cdma2000.



  Models, Options, & Accessories


Model Description List Price Sale Price
E9321A Peak and Average Power Sensor, 50 MHz to 6 GHz, 300 kHz bandwidth
$1650.00 
E9322A Peak and Average Power Sensor, 50 MHz to 6 GHz, 1.5 MHz bandwidth
$2206.00 
E9323A Peak and Average Power Sensor, 50 MHz to 6 GHz, 5 MHz bandwidth
$3036.00 
E9325A Peak and Average Power Sensor, 50 MHz to 18 GHz, 300 kHz bandwidth
$1990.00 
E9326A Peak and Average Power Sensor, 50 MHz to 18 GHz, 1.5 MHz bandwidth
$2645.00 
E9327A Peak and Average Power Sensor, 50 MHz to 18 GHz, 5 MHz bandwidth
$3529.00 
Model Options List Price Sale Price
E9323A-A6J ANSI Z540 compliant calibration with test data
$317.00 



  Specifications

Sensor model Video bandwidth Frequency range Power range Maximum power Connector type
Average only mode Normal mode1
E9321A 300 kHz 50 MHz to 6 GHz -65 dBm to +20 dBm -50 dBm to +20 dBm +23 dBm average;
+30 dBm peak
(< 10 μsec duration)
Type N (m)
E9325A 50 MHz to 18 GHz
E9322A 1.5 MHz 50 MHz to 6 GHz -60 dBm to +20 dBm -45 dBm to +20 dBm
E9326A 50 MHz to 18 GHz
E9323A 5 MHz 50 MHz to 6 GHz -60 dBm to +20 dBm -40 dBm to +20 dBm
E9327A 50 MHz to 18 GHz
  1. For average power measurements, free run acquisition.
  Lower and upper measurement ranges

  E9321A/E9325A E9322A/E9326A E9323A/E9327A
  Normal Average only Normal Average only Normal Average only
Lower range
(min. power)
-50 dBm -65 dBm -45 dBm -60 dBm -40 dBm -60 dBm
Lower range
(max. power)
Lower to upper auto range point
+0.5 dBm -17.5 dBm1 -5 dBm -13.5 dBm1 -5 dBm -10.5 dBm1
Upper to lower auto range point -9.5 dBm -18.5 dBm -15 dBm -14.5 dBm -15 dBm -11.5 dBm
Upper range
(min. power)
-35 dBm -50 dBm -35 dBm -45 dBm -30 dBm -35 dBm
Upper range
(max. power)
+20 dBm +20 dBm1 +20 dBm +20 dBm1 +20 dBm +20 dBm1
  1. Applies to CW and constant amplitude signals only above –20 dBm.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET