Our agents are available:
9:00 AM - 6:00 PM EST
Agilent DSO7052A 7000 Series
500 MHz 2 channels
InfiniiVision Oscilloscope
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Agilent DSO7052A 7000 Series
500 MHz 2 channels
InfiniiVision Oscilloscope




Click image to enlarge

 Agilent  DSO7052A

Features:
  • 500 MHz
  • 4 GSa/s sample rate
  • 2 Channels
  • Flexibility to upgrade to an MSO at any time
  • Standard 8 Mpts MegaZoom III memory
  • High-definition XGA (1024 x 768) color display with 256 intensity levels
  • Update rate to 100,000 waveforms/sec, uncompromised
  • Standard USB, LAN (LXI Class C)
  • Front panel USB for memory stick storage
  • XGA video output
  • Powerful triggering including analog HDTV, CAN, I2C, LIN, SPI, and USB
  • Built-in help system
  • Three-year warranty


Click image to enlarge
Rear View



Click image to enlarge
Rear Connections Panel



Click image to enlarge
Side View




  Screen Shots


Click image to enlarge


Click image to enlarge


Click image to enlarge


Click image to enlarge


Click image to enlarge


Click image to enlarge


Click image to enlarge


Click image to enlarge




  Description

Agilent InfiniiVision 7000 Series Oscilloscopes: Engineered for the best signal visibility

The new Agilent InfiniiVision 7000 Series offers bandwidths up to 1 GHz and delivers an unparalleled deep memory waveform update rate of up to 100,000 waveforms per second. Each model, equipped with the industry’s largest display - a 12.1 inch XGA LCD display - comes in a package that is just 7" deep and weighs only 14 pounds.

Benefits of the Agilent InfiniiVision 7000 Series oscilloscopes include:

Biggest display
Oscilloscopes are visual tools and large, high-resolution screens make the product better. Bigger displays have become increasingly important as general purpose scopes need more space to display digital and serial signals in addition to traditional scope channels. The increased display size helps you easily view up to 20 channels simultaneously with serial protocol. At 12.1 inches the display is nearly 40% bigger than any competitive model.

Fastest update rate
InfiniiVision Series 7000 models provide the industry's fastest update rate - up to 100,000 waveforms per second - eliminating two common errors that can cause engineers to miss critical information: unresponsive controls with deep memory turned on, and traditional architectures that are blind to changes in signals being tested. For designs with both digital and analog signal measurements, the update rate is 5,000 times faster than any other available scope. This allows the user to view critical signal detail that competitive scopes miss with their longer dead times.

Turn knobs and the instrument responds instantly and effortlessly. Need to also view digital channels? The instrument stays responsive. Decoding serial packets? Offering the industry’s only hardware-accelerated serial bus decode, Agilent’s InfiniiVision series delivers serial debug without compromising analog measurements.

Most comprehensive suite of applications

Packed with numerous general purpose features, InfiniiVision 7000 Series oscilloscopes can be customized with a number of unique software options. Supported applications give engineers meaningful insight into application-specific problems. Applications include:

  • Serial decode and trigger for I2C, SPI, CAN, LIN, FlexRay, RS-232 and other UART
  • Rapid core-assisted debug of designs with Xilinx or Altera FPGAs
  • Segmented Memory for analysis of laser pulses, radar bursts and serial packets.
  • Power Measurement Application for a full suite of power measurements.
  • Offline PC viewing and sharing of previously acquired scope data.
  • View the Agilent InfiniiVision Introduction Demo

Agilent has been the fastest growing oscilloscope supplier since 1997 (source: Prime Data, 2007). Wonder why? Agilent engineers developed the InfiniiVision 7000 Series with advanced technology that will allow you to see more subtle signal detail and more infrequent events than any other scope on the market. See the InfiniiVision 7000 Series oscilloscope—the industry's best for signal viewing.




  Software Applications

Offline viewing and analysis (Accessory - B4610A)

Need to view and analyze scope data away from your scope? Need to share measurement data with geographically dispersed team members? Save your scope data to a USB or network drive and import the data into a PC-based offl ine viewer. Pan and zoom. Use searching and fi ltering to gain insight on analog and digital buses. Email the data to team members who can use the same tool at their PCs.

Secure environment mode (Accessory - Option SEC)

Option SEC – secure environment mode provides the highest level of security by ensuring internal nonvolatile memory is clear of all setup and trace settings in compliance with National Industrial Security Program Operation Manual (NISPOM) Chapter 8 requirements. When this option is installed, it will store setup and trace settings to internal volatile memory only.

Volatile memory will be cleared during the power off cycle of the instrument. So you can move the instrument out of a secure area with confidence.




  Models, Options, & Accessories


Model Description List Price Sale Price
DSO7052A 500MHz, 2-channel oscilloscope
$9300.00 
DSO7032A 350MHz 2-channel oscilloscope
$6950.00 
DSO7034A 350MHz 4-channel oscilloscope
$8850.00 
DSO7054A 500MHz, 4-channel oscilloscope
$11050.00 
DSO7104A 1GHz, 4-channel oscilloscope
$13950.00 
Model Options List Price Sale Price
U1241A True-rms 10000 Count Handheld DMM
$200.00 
N2732A Rackmount kit for 7000 Series oscilloscopes
$500.00 
N2733A Soft Carrying Case for 7000 Series oscilloscope
$150.00 
N2735A/002 Please call or email us for pricing and availability.
N2735A/004 Please call or email us for pricing and availability.
N2736A/002 Please call or email us for pricing and availability.
N2736A/004 Please call or email us for pricing and availability.
N2737A DSO to MSO Upgrade Kit for DSO710XA Scopes
$3950.00 
N5406A/001 Please call or email us for pricing and availability.
N5406A/002 Please call or email us for pricing and availability.
N5423A I2C and SPI Low Speed Serial Decode (4 channel 6000 series)
$1250.00 
N5424A CAN and LIN Automotive Serial Decode
$1250.00 
N5457A RS232/UART Serial Decode and Trigger
$1250.00 
N5432A FlexRay Decode and Trigger; Requires DECOMSYS BusDoctor2 and 183108 connectivity kit
$3061.00 
N5434A/001 Please call or email us for pricing and availability.
N5434A/002 Please call or email us for pricing and availability.
N5454A Segmented Memory
$1250.00 
Opt. SEC Please call or email us for pricing and availability.
B4610A/010 Please call or email us for pricing and availability.
B4610A/020 Please call or email us for pricing and availability.
U1881A/001 Please call or email us for pricing and availability.
U1881A/002 Please call or email us for pricing and availability.



  Series Comparison

Agilent Infiniium 7000 Series Comparison Chart
Model Bandwidth Sample Rate Memory Depth Scope Channels Digital Channels
DSO7032A 350 MHz 2 GSa/s 8 Mpts 2  
DSO7034A 350 MHz 2 GSa/s 8 Mpts 4  
MSO7032A 350 MHz 2 GSa/s 8 Mpts 2 16
MSO7034A 350 MHz 2 GSa/s 8 Mpts 4 16
DSO7052A 500 MHz 4 GSa/s 8 Mpts 2  
DSO7054A 500 MHz 4 GSa/s 8 Mpts 4  
MSO7052A 500 MHz 4 GSa/s 8 Mpts 2 16
MSO7054A 500 MHz 4 GSa/s 8 Mpts 4 16
DSO7104A 1 GHz 4 GSa/s 8 Mpts 4  
MSO7104A 1 GHz 4 GSa/s 8 Mpts 4 16



  Specifications

Acquisition - scope channels
Sample rate MSO/DSO703xA: 2 GSa/sec each channel
MSO/DSO705xA/710xA: 4 GSa/sec half channel*, 2 GSa/sec each channel
Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off)
Memory depth Standard 2 channels/4 channels
8 Mpts/4 Mpts
Vertical resolution 8 bits
Peak detection MSO/DSO703xA: 500-ps peak detect
MSO/DSO705xA/710xA: 250-ps peak detect
Averaging Selectable from 2, 4, 8, 16, 32, 64 … to 65536
High resolution mode Average mode with avg = 1
12 bits of resolution when ≥10 μs/div at 4 GSa/s or ≥20-μs/div at 2 GSa/s
Filter Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of scope, whichever is less) with vectors on and in real-time mode

Acquisition - digital channels (7000 Series MSO or MSO-upgraded 7000 Series DSO)
Sample rate 2 GSa/sec one pod**, 1 GSa/sec each pod
Maximum input frequency 250 MHz
Memory depth Standard One pod/both pods (with scope channels turned off) - 8 Mpts/4 Mpts
One pod/both pods (with scope channels turned on) - 2.5 Mpts/ 1.25 Mpts
Vertical resolution 1 bit
Glitch detection 2 ns (min pulse width)

  * - Half channel is when one of channel 1 or 2 is turned on, and/or one of channel 3 or 4 is turned on.
  ** - A pod is a group of eight digital channels, either 0-7 or 8-15.

Vertical system - scope channels
Scope channels MSO/DSO7xx2A: Ch 1 and 2 simultaneous acquisition
MSO/DSO7xx4A: Ch 1, 2, 3 and 4 simultaneous acquisition
Bandwidth (–3 dB)* MSO/DSO703xA: DC to 350 MHz
MSO/DSO705xA: DC to 500 MHz
MSO/DSO710xA DC to 1 GHz
AC coupled MSO/DSO703xA: 3.5 Hz to 350 MHz
MSO/DSO705xA: 3.5 Hz to 500 MHz
MSO/DSO710xA 3.5 Hz to 1 GHz
Calculated rise time (=0.35/bandwidth) MSO/DSO703xA: 1 nsec
MSO/DSO705xA: 700 psec
MSO/DSO710xA: 350 psec
Single-shot bandwidth MSO/DSO703xA: 350 MHz
MSO/DSO705xA: 500 MHz
MSO/DSO710xA: 1 GHz (in half-channel mode)
Range** MSO/DSO703xA and MSO/DSO705xA: 2 mV/div to 5 V/div (1 MΩ or 50 Ω)
MSO/DSO710xA: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
Maximum input CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
CAT II 100 Vrms, 400 Vpk
With 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
Offset range ±5 V on ranges <10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div;
±75 V on ranges >200 mV/div
Dynamic range ±8 div
Input impedance 1 MΩ ± 1% || 14 pF or 50 Ω ± 1.5%, selectable Coupling AC, DC BW limit 25 MHz selectable
Channel-to-channel isolation DC to max bandwidth >40 dB
Standard probes 10073C shipped standard for each scope channel (1165A probes optional)
Probe ID Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense
ESD tolerance ±2 kV
Noise peak-to-peak MSO/DSO703xA: 3% full scale or 3 mV, whichever is greater
MSO/DSO705xA: 3% full scale or 3.6 mV, whichever is greater
MSO/DSO710xA: 3% full scale or 4 mV, whichever is greater
DC vertical gain accuracy** ±2.0% full scale
DC vertical offset accuracy ≤200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value
>200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
Single cursor accuracy** ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)}
Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0% (80 mV) + 0.1 (10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2% (80 mV)} = ± 4.785 mV
Dual cursor accuracy** ±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)}
Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0% (80 mV) + 0.4% (80 mV)} = ±1.92 mV

Vertical system - digital channels (MSO or MSO-upgraded DSO)
Number of channels 16 logic timing channels – labeled D15 - D0
Threshold groupings Pod 1: D7 - D0
Pod 2: D15 - D8
Threshold selections TTL, CMOS, ECL and user-definable (selectable by pod)
User-defined threshold range ±8.0 V in 10 mV increments
Maximum input voltage ±40 V peak CAT I; transient overvoltage 800 Vpk
Threshold accuracy* ±(100 mV + 3% of threshold setting)
Input dynamic range ±10 V about threshold
Minimum input voltage swing 500 mV peak-to-peak
Input capacitance ~8 pF with flying leads
Input resistance 100 kO ±2% at probe tip
Channel-to-channel skew 2 ns typical, 3 ns maximum

Horizontal
Range MSO/DSO703xA: 2 nsec/div to 50 sec/div
MSO/DSO705xA: 1 nsec/div to 50 sec/div
MSO/DSO710xA: 500 psec/div to 50 sec/div
Resolution 2.5 ps
Time base accuracy 15 ppm (±0.0015%)
Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on
Delay range Pre-trigger (negative delay): Greater of 1 screen width or 1 ms
Post-trigger (positive delay): 1 s to 500 seconds
Analog delta-t accuracy Same channel: ±0.0015% reading ±0.1% screen width ±20 ps
Channel-to-channel: ±0.0015% reading ±0.1% screen width ±40 ps
Same channel example (MSO/DSO705xA):
For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{0.0015% (10 µs) + 0.1% (50 µs) + 20 ps} = 50.17 ns
Logic delta-t accuracy Same channel: ±0.005% reading ±0.1% screen width ±(1 logic sample period, 1 ns)
Channel-to-channel: ±0.005% reading ±0.1% screen width ±(1 logic sample period) ±chan-to-chan skew
Same channel example: For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{0.005% (10 µs) + 0.1% (50 µs) + 1 ns} = 51.5 ns
Modes Main, zoom, roll, XY, segmented (optional)
XY Bandwidth: Max bandwidth
Phase error @ 1 MHz: <0.5 degrees
Z Blanking: 1.4 V blanks trace (use external trigger on MSO/DSO7xx2A, channel 4 on MSO/DSO7xx4A)
Reference positions Left, center, right
Segmented memory re-arm time 10 µs maximum, 7.5 µs typical

Trigger system
Sources MSO7xx2A: Ch 1, 2, line, ext, D15 - D0
DSO7xx2A: Ch 1, 2, line, ext
MSO7xx4A: Ch 1, 2, 3, 4, line, ext, D15 - D0
DSO7xx4A: Ch 1, 2, 3, 4, line, ext
Modes Auto, normal (triggered), single
Holdoff time ~60 ns to 10 seconds
Trigger jitter 15 ps rms
Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay, USB, I2C, SPI, Nth edge burst
Edge Trigger on a rising, falling, alternating or either edge of any source
Pattern Trigger at the beginning of a pattern of high, low, and don’t care levels and/or a rising or falling edge established across any of the analog and digital channels, but only after a pattern has stabilized for a minimum of 2 nsec.
The scope channel’s high or low level is defined by that channel’s trigger level. The logic channel’s trigger level is defined by the threshold for the pod, 0 - 7 or 8 - 15.
Pulse width Trigger when a positive- or negative-going pulse is less than, greater than, or within a specified range on any of the source channels.
Minimum pulse width setting: 5 ns (MSO/DSO703xA scope channels)
2 ns (MSO/DSO705xA/710xA scope channels)
2 ns (logic channels on 7000 Series MSO or MSO-upgraded 7000 Series DSO)
Maximum pulse width setting: 10 s
TV Trigger using any scope channel on most analog progressive and interlaced video standards including HDTV/EDTV, NTSC, PAL, PAL-M or SECAM broadcast standards. Select either positive or negative sync pulse polarity. Modes supported include Field 1, Field 2, all fields, all lines, or any line within a field. TV trigger sensitivity: 0.5 division of sync signal. Trigger holdoff time can be adjusted in half field increments.
Sequence Arm on event A, trigger on event B (edge or pattern), with option to reset on event C or time delay.
CAN Trigger on CAN (controller area network) version 2.0A and 2.0B signals. Trigger on the start of frame (SOF) bit (standard). N5424A option supports triggering on remote frame ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame ID and data, error frame, all errors, acknowledge error and overload frame.
LIN Trigger on LIN (local interconnect network) sync break at beginning of message frame (standard). N5424A option supports triggering on frame ID.
FlexRay N5432A option supports trigger on FlexRay frame ID or time slot or specific error condition, along with cycle-base and repetition-cycle filtering.
USB Trigger on USB (universal serial bus) start of packet, end of packet, reset complete, enter suspend, or exit suspend on the differential USB data lines. USB low speed and full speed are supported.
I2C Trigger on I2C (inter-IC bus) serial protocol at a start/stop condition or user defined frame with address and/or data values. Also trigger on missing acknowledge, address with no acq, restart, EEPROM read, and 10-bit write.
SPI Trigger on SPI (serial protocol interface) data pattern during a specific framing period.
Supports positive and negative Chip Select framing as well as clock idle framing and user-specified number of bits per frame.
RS-232/UART This application eliminates the need to manually decode bus traffic. Using data captured on the scope or digital channels, the application provides the ability to easily view the information sent over a RS-232 serial bus. Display real-time time-aligned decode of transmit and receive lines. The application also enables triggering on RS-232/UART conditions.
Duration Trigger on a multi-channel pattern whose time duration is less than a value, greater than a value, greater than a time value with a timeout, or inside or outside of a set of time values.
Minimum duration setting: 2 ns
Maximum duration setting: 10 s
Nth edge burst Trigger on the Nth edge of a burst that occurs after an idle time that you specify.
Max edge count: 65,536.
Autoscale Finds and displays all active scope and logic (for 7000 Series MSO) channels, sets edge trigger mode on highest-numbered channel, sets vertical sensitivity on scope channels and thresholds on logic channels, time base to display ~1.8 periods. Requires minimum voltage >10 mVpp, 0.5% duty cycle and minimum frequency >50 Hz.

Scope channel triggering
Range (internal) ±6 div from center screen
Sensitivity* <10 mV/div: greater of 1 div or 5 mV; =10 mV/div: 0.6 div
Coupling AC, ~10 Hz on MSO/DSO703xA/705xA/710xA), DC, noise reject, HF reject and LF reject (~50 kHz)

Digital (D15 - D0) channel triggering (7000 Series MSO or MSO-upgraded 7000 Series DSO)
Threshold range (user defined) ±8.0 V in 10 mV increments
Threshold accuracy* ±(100 mV + 3% of threshold setting)
Predefined thresholds TTL = 1.4 V, CMOS = 2.5 V, ECL = –1.3 V

External (EXT) triggering MSO/DSO7xx2A
(2-/2+16-ch models)
MSO/DSO7xx4A
(4-/4+16-ch models)
Input impedance 1 MΩ ± 3% || 14 pF or 50Ω 2.14 kΩ ±5%
Maximum input CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk
With 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
5 Vrms with 50-Ω input
±15V
Range DC coupling: trigger level ±1 V and ±8 V ±5 V
Sensitivity For ±1 V range setting
DC to 100 MHz, 100 mV;
For ±8 V range setting
DC to 100 MHz, 250 mV;
>100 MHz to bandwidth of oscilloscope: 500 mV
DC to 500 MHz: 500 mV
Coupling AC (~3.5 Hz), DC, noise reject, HF reject and LF reject (~50 kHz)
Probe ID Auto probe sense and AutoProbe interface
Agilent- and Tektronix-compatible passive probe sense

Display system
Display 12.1-inch (255 mm x 184 mm) diagonal color TFT LCD
Throughput of scope channels Up to 100,000 waveforms/sec in real-time mode
Resolution XGA – 768 vertical by 1024 horizontal points (screen area);
640 vertical by 1000 horizontal points (waveform area)
256 levels of intensity scale
Controls Waveform intensity on front panel. Vectors on/off;
infinite persistence on/off,
8 x 10 grid with intensity control
Built-in help system Key-specific help displayed by pressing and holding key or softkey of interest.
Language support for 11 languages including English, German, French, Russian, Japanese, Traditional Chinese, Simplified Chinese, Korean, Spanish, Portuguese and Italian.
Real-time clock Time and date (user adjustable)

Measurement features
Automatic measurements Measurements are continuously updated. Cursors track last selected measurement.
Up to four measurements can be displayed on screen at any one time.
Voltage (scope channels only) Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation (AC RMS)
Time Frequency, period, + width, – width and duty cycle on any channel.
Rise time, fall time, X at max Y (time at max volts), X at min Y (time at min volts), delay, and phase on scope channels only.
Counter Built-in 5-digit frequency counter on any channel. Counts up to the scope’s bandwidth (1 GHz max). The counter resolution can be increased to 8 digits with an external 10-MHz reference.
Threshold definition Variable by percent and absolute value; 10%, 50%, 90% default for time measurements
Cursors Manually or automatically placed readout of horizontal (X, ?X, 1/?X) and vertical (Y, ?Y).
Additionally logic or scope channels can be displayed as binary or hex values.
Waveform math One function of 1-2, 1x2, FFT, differentiate, integrate, square root.
Source of FFT, differentiate, integrate: scope channels 1 or 2, 1-2, 1+2, 1x2.

FFT
Points Fixed at 1000 points
Source of FFT Scope channels 1 or 2 (or 3 or 4 on MSO/DSO7xx4A only), 1+2, 1-2, 1*2
Window Rectangular, flattop, Hanning
Noise floor –50 to –90 dB depending on averaging
Amplitude Display in dBV, dBm at 50 O
Frequency resolution 0.05/time per div
Maximum frequency 50/time per div

Storage
Save/recall (non-volatile) 10 setups and traces can be saved and recalled internally.
Optional secure environment mode ensures setups and traces are stored to internal volatile memory so data is erased when power is removed.
Compliant to NISPOM Chapter 8 requirements.
Storage type and format USB 1.1 host ports on front and rear panels
Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit)
Data formats: X and Y (time/voltage) values in CSV format, ASCII XY and binary format and .alb for offline viewing on a PC
Trace/setup formats: Recalled

I/O
Standard ports USB 2.0 high-speed device, two USB 1.1 host ports, 10/100BaseT LAN, XGA video output
Max transfer rate USB (USBTMC-USB488): 3.5 Mbytes/sec
100 Mbps LAN (TCP/IP): 1 Mbytes/sec
Supported printers via USB For a list of currently supported printers visit www.agilent.com/fi nd/Infi niiVision-printers

General characteristics
Physical size (WxHxD) 17.9” x 11.7” x 8.6” (45.4 cm x 29.8 cm x 22 cm) with legs extended, with screen cover on
17.9” x 10.9” x 6.8” (45.4 cm x 27.7 cm x 17.3 cm) with legs contracted, with screen cover on
Weight; Net 5.9 kg (13 lbs)
Shipping: 9.3 kg (20.5 lbs)
Probe comp output Frequency ~2 kHz; Amplitude ~5 V
Trigger out When Triggers is selected (delay ~17 ns)
0 to 5 V into high impedance
0 to 2.5 V into 50 O
When Source Frequency or Source Frequency/8 is selected
0 to 580 mV into high impedance
0 to 290 mV into 50 O
Max frequency output: 350 MHz (in source frequency mode when terminated in 50 O)
125 MHz (in source frequency/8 mode when terminated in 50 O)
10 MHz ref in/out TTL out, 180 mV to 1 V amplitude with 0 to 2 V offset
Kensington lock Connection on rear panel for security

Power requirements
Line voltage range ~Line 120 W max, 96-144 V/48-440 Hz, 192-288 V/48-66 Hz, automatic selection
Line frequency 50/60 Hz, 100-240 VAC; 440 Hz, 100-132 VAC
Power usage 110 W max

Environmental characteristics
Ambient temperature Operating –10 °C to +55 °C;
non-operating –65 °C to +71 °C
Humidity Operating 95% RH at 40 °C for 24 hr;
non-operating 90% RH at 65 °C for 24 hr
Altitude Operating to 4,570 m (15,000 ft);
non-operating to 15,244 m (50,000 ft)
Vibration Agilent class B1 and MIL-PRF-28800F; class 3 random
Shock Agilent class B1 and MIL-PRF-28800F; class 3 random;
(operating 30g, 1/2 sine, 11 ms duration, 3 shocks/axis along major axis, total of 18 shocks)
Pollution degree2 Normally only dry non-conductive pollution occurs.
Occasionally a temporary conductivity caused by condensation must be expected.
Typical operator noise 30 dBa at front of instrument, 35 dBa at rear of instrument.
Indoor use Rated for indoor use only

Other
Measurement categories CAT I: Mains isolated
CAT II: Line voltage in appliance and to wall outlet
Regulatory information Safety IEC 61010-1:2001 / EN 61010-1:2001
Canada: CSA C22.2 No. 1010.1:1992
UL 61010B-1:2003
Supplementary information The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly.
The product was tested in a typical configuration with HP/Agilent test systems.

  * - Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
  ** - 2 mV/div setting for 100 MHz models and 2 mV/div is a magnification of 4 mV/div setting for 350 MHz to 1 GHz models. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting and 32 mV for 2 mV/div sensitivity setting.




   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET