Agilent DSO5054A 5000 Series 500 MHz 4 channels Oscilloscope with MegaZoom III technology

Click image to enlarge
Agilent DSO5054A
|
|
Features:
- 500 MHz bandwidth
- 4 channels
- MegaZoom III memory and display technology, up to 4 GSa/s
- Up to 12 bits of vertical resolution, even in single-shot acquisitions
- Up to 1 Mpts acquisition memory
- Up to 100,000 waveforms per second real-time update rate
- Complete connectivity – USB (3 ports), LAN, GPIB
- XGA display out
- Full remote control, including web browser
- High-definition XGA (1024 x 768) display with 256 levels of intensity grading
- LXI-C compliant
- Serial triggering and hardware-accelerated decode for I2C, SPI, CAN, LIN, and USB (trigger only) on 4-channel models
|
Description
|
Leading-edge technology for all scope users
The 5000 Series oscilloscopes leverage the same third-generation MegaZoom III technology blocks used in our higher performance bench and lab oscilloscopes – responsive deep memory, fast update rates with minimal “dead time,” and analog-like display systems – and deliver them in a compact package, at a price similar to oscilloscopes with older technology blocks.
MegaZoom III technology provides industry-leading performance with the:
Industry-leading customer support
As the world’s leading test and measurement vendor, Agilent maintains the largest network of sales engineers, application engineers, support engineers and technicians. From pre-sales collaboration, to calibration, to training and consulting, to repair and servicing, Agilent stands with you throughout the life of your product. It’s no accident that Agilent has such loyal customers.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| DSO5054A |
500MHz, 4-channel Oscilloscope |
| $10245.00 |  |
|
| DSO5012A |
100MHz, 2-channel Oscilloscope |
| $4151.00 |  |
|
| DSO5014A |
100MHz, 4-channel Oscilloscope |
| $5023.00 |  |
|
| DSO5032A |
300MHz, 2-channel Oscilloscope |
| $5637.00 |  |
|
| DSO5034A |
300MHz, 4-channel Oscilloscope |
| $7072.00 |  |
|
| DSO5052A |
500MHz, 2-channel Oscilloscoe |
| $8405.00 |  |
|
| Model |
Options |
List Price |
Sale Price |
| U1241A |
True-rms 10000 Count Handheld DMM |
| $200.00 |  |
|
| N5423A |
I2C and SPI Low Speed Serial Decode (4 channel 6000 series) |
| $1250.00 |  |
|
| N5424A |
CAN and LIN Automotive Serial Decode |
| $1250.00 |  |
|
| 10073C |
10:1, 1 MOhm, 1.5m, Passive Probe |
| $296.00 |  |
|
| N2863A |
DSO3000 10:1 passive probe 300MHz |
| $135.00 |  |
|
| N2916B |
Rackmount kit for 5000 and 6000 Series oscilloscopes |
| $690.00 |  |
|
| U3000A |
Electronic Instrumentation Training Kit |
| $200.00 |  |
|
Specifications
| Acquisition |
| Sample rate |
DSO501xA/503xA: 2 GSa/a each channel DSO505xA: 4 GSa/s half channel*, 2 GSa/s each channel |
| Equivalent-time sample rate |
400 GSa/s (when real-time mode is turned off) |
| Memory depth |
1 Mpts half channel*, 500 kpts each channel |
| Vertical resolution |
8 bits, up to 12 in high-resolution or averaging modes |
| Peak detection |
DSO501xA: 1 ns peak detect DSO503xA: 500 ps peak detect DSO505xA: 250 ps peak detect |
| Averaging |
Selectable from 2, 4, 8, 16, 32, 64 … to 65536 |
| High resolution mode |
Average mode with #avg = 1 12 bits of resolution when ≥10 μs/div, at 4 GSa/s or ≥20 μs/div, at 2 GSa/s |
| Filter |
Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of oscilloscope, whichever is less) with vectors on and in real-time mode |
| Vertical system |
| Scope channels |
DSO50x2A: 2 Ch 1 and 2 simultaneous acquisition DSO50x4A: Ch 1, 2, 3, and 4 simultaneous acquisition |
| Bandwidth (–3dB)** |
DSO501xA: DC to 100 MHz DSO503xA: DC to 300 MHz DSO505xA: DC to 500 MHz |
| AC coupled |
DSO501xA: 3.5 Hz to 100 MHz DSO503xA: 3.5 Hz to 300 MHz DSO505xA: 3.5 Hz to 500 MHz |
| Calculated rise time (= 0.35/bandwidth) |
DSO501xA: 3.5 nsec DSO503xA: 1.17 nsec DSO505xA: 700 psec |
| Single-shot bandwidth |
DSO501xA: 100 MHz DSO503xA: 300 MHz DSO505xA: 500 MHz |
| Range*** |
2 mV/div to 5 V/div (1 MΩ or 50 Ω) |
| Maximum input |
Maximum input voltage for analog inputs: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk CAT II 100 Vrms, 400 Vpk with N2863A 10:1 probe: CAT I 600 V, CAT II 300 V (DC + peak AC) with 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk with 50 Ω input: 5 Vrms, CAT I |
| Offset range |
±5 V on ranges < 10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div; ±75 V on ranges >200 mV/div |
| Dynamic range |
±8 div |
| Input impedance |
1 MΩ ± 1% || 12 pF or 50 Ω ± 1.0%, selectable |
| Coupling |
AC, DC |
| BW limit |
25 MHz selectable |
| Channel-to-channel isolation |
DC to max bandwidth > 40 dB |
| Standard probes |
DSO501xA: 10:1 N2863A shipped standard for each oscilloscope channel DSO503xA: 10:1 N2863A shipped standard for each oscilloscope channel DSO505xA: 10:1 10073C shipped standard for each oscilloscope channel |
| Probe ID |
Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense |
| ESD tolerance |
±2 kV |
| Noise peak-to-peak |
DSO501xA: 0.5% full scale or 250 μV, whichever is greater DSO503xA: 0.5% full scale or 300 μV, whichever is greater DSO505xA: 0.5% full scale or 360 μV, whichever is greater |
| DC vertical gain accuracy** |
±2.0% full scale |
| DC vertical offset accuracy |
≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; > 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value |
| Single cursor accuracy*** |
±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)} Example: for 50 mV signal, oscilloscope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0% (80 mV) + 0.1 (10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2%(80 mV)} = ± 4.785 mV |
| Dual cursor accuracy*** |
±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)} Example: for 50 mV signal, oscilloscope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0% (80 mV) + 0.4% (80 mV)} = ±1.92 mV |
| Horizontal |
| Range |
DSO501xA: 5 nsec/div to 50 sec/div DSO503xA: 2 nsec/div to 50 sec/div DSO505xA: 1 nsec/div to 50 sec/div |
| Resolution |
2.5 psec |
| Timebase accuracy |
25 ppm (0.0025%) to 40° C, plus 1 ppm per ° C from 40° C, to 55° C |
| Vernier |
1-2-5 increments when off, ~25 minor increments between major settings when on |
| Delay range |
Pre-trigger (negative delay): Greater of 1 screen width or 125 μs Post-trigger (positive delay): 1 s to 500 seconds |
| Channel delta-t accuracy |
Same channel: ±0.0025% reading ±0.1% screen width ±20 ps Channel-to-channel: ±0.0025% reading ±0.1% screen width ±40 ps Same channel example (DSO505xA): For signal with pulse width of 10 μs, oscilloscope set to 5 μs/div (50 μs screen width), delta-t accuracy = ±{0.0025% (10 μs) + 0.1% (50 μs) + 20 ps} = 50.27 ns |
| Modes |
Main, delayed, roll, XY |
| XY |
Bandwidth: Max bandwidth Phase error at 1 MHz: < 0.5 degrees Z Blanking: 1.4 V blanks trace (use external trigger on DSO50x2A, channel 4 on DSO50x4A) |
| Reference positions |
Left, center, right |
| Trigger system |
| Sources |
DSO50x2A: Ch 1, 2, line, ext DSO50x4A: Ch 1, 2, 3, 4, line, ext |
| Modes |
Auto, normal (triggered), single |
| Holdoff time |
~60 ns to 10 seconds |
| Trigger jitter |
15 ps rms |
| Selections |
Edge, pulse width, pattern, TV, duration |
| Edge |
Trigger on a rising, falling, or alternating edge of any source |
| Pulse width |
Trigger when a positive- or negative-going pulse is less than, greater than, or within a specified range on any of the source channels. Minimum pulse width setting: 5 ns (DSO501xA) 2 ns (DSO503xA, DSO505xA) Maximum pulse width setting: 10 s |
| Pattern |
Trigger at the beginning of a pattern of high, low, and don't care levels and/or a rising or falling edge established across any of the channels, but only after a pattern has been established for a minimum of 2 nsec. The channel’s high or low level is defined by that channel’s trigger level. |
| TV |
Trigger using any oscilloscope channel on most analog progressive and interlaced video standards including HDTV/EDTV, NTSC, PAL, PAL-M or SECAM broadcast standards. Select either positive or negative sync pulse polarity. Modes supported include Field 1, Field 2, all fields, all lines, or any line within a field. TV trigger sensitivity 0.5 division of sync signal. Trigger holdoff time can be adjusted in half field increments. |
| Duration |
Trigger on a multi-channel pattern whose time duration is less than a value, greater than a value, greater than a time value with a timeout, or inside or outside of a set of time values. Minimum duration setting: 2 ns Maximum duration setting: 10 s |
| CAN |
Trigger on CAN (Controller Area Network) version 2.0A and 2.0B signals. Trigger on the start of frame (SOF) bit (standard). N5424A option supports triggering on remote frame ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame ID and data, error frame, all errors, acknowledge error and overload frame. |
| LIN |
Trigger on LIN (Local Interconnect Network) sync break at beginning of message frame (standard). N5424A option supports triggering on frame ID. |
| USB |
Trigger on USB (Universal Serial Bus) start of packet, end of packet, reset complete, enter suspend, or exit suspend on the differential USB data lines. USB low speed and full speed are supported. |
| I2C |
Trigger on I2C (Inter-IC bus) serial protocol at a start/stop condition or user defined frame with address and/or data values. Also trigger on missing acknowledge, address with no acq, restart, EEPROM read, and 10-bit write. |
| SPI |
Trigger on SPI (Serial Protocol Interface) data pattern during a specific framing period. Supports positive and negative Chip Select framing as well as clock Idle framing and user-specified number of bits per frame. |
| AutoScale |
Finds and displays all active channels, sets edge trigger mode on highest-numbered channel, sets vertical sensitivity on channels, time base to display ~1.8 periods. Requires minimum voltage > 10 mVpp, 0.5% duty cycle and minimum frequency > 50 Hz. |
| Channel triggering |
| Range (internal) |
±6 div from center screen |
| Sensitivity** |
< 10 mV/div: greater of 1 div or 5mV; ≥ 10 mV/div: 0.6 div |
| Coupling |
AC (~10 Hz), DC, noise reject, HF reject and LF reject (~50 kHz) |
| External (EXT) triggering |
DSO50x2A |
DSO50x4A |
| Input impedance |
1 MΩ ±3% || 12 pF or 50 Ω ±1% |
1.015 kΩ ±5% |
| Maximum input |
CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk V CAT II 100 Vrms, 400 Vpk with N2863A 10:1 probe: CAT I 600 V, CAT II 300 V (DC + peak AC) with 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk 5 Vrms with 50-Ω input, CAT I |
±15 V |
| Range |
DC coupling: trigger level ± 1 V and ± 8 V |
±5 V |
| Sensitivity |
For ± 1V range setting: DC to 100 MHz, 100 mV, >100 MHz to bandwidth of the oscilloscope, 200 mV For ±8 V range setting: DC to 100 MHz, 250 mV; >100 MHz to bandwidth of the oscilloscope, 500 mV |
DC to 100 MHz, 500 mV |
| Coupling |
AC (~10 Hz), DC, noise reject, HF reject and LF reject (~50 kHz) |
|
| Probe ID |
Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense |
|
| Display system |
| Display |
6.3-inch (161 mm) diagonal color TFT LCD |
| Display update rate |
Up to 100,000 waveforms/sec in real-time mode |
| Resolution |
XGA: 768 vertical by 1024 horizontal points (screen area); 640 vertical by 1000 horizontal points (waveform area) 256 levels of intensity scale |
| Controls |
Waveform intensity on front panel. Vectors on/off; infinite persistence on/off, 8 x 10 grid with intensity control Built-in help system Key-specific help displayed by pressing and holding key or softkey of interest |
| Real-time clock |
Time and date (user adjustable) |
| Measurement features |
| Automatic measurements |
Measurements are continuously updated. Cursors track last selected measurement. |
| Voltage |
Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation |
| Time |
Frequency, period, + width, – width and duty cycle on any channel. Rise time, fall time, X at max Y (time at max volts), X at min Y (time at min volts), delay, and phase on oscilloscope channels only. |
| Counter |
Built-in 5-digit frequency counter on any channel. Counts up to the oscilloscope’s bandwidth. |
| Threshold definition |
Variable by percent and absolute value; 10%, 50%, 90% default for time measurements |
| Cursors |
Manually or automatically placed readout of Horizontal (X, ΔX, 1/ΔX) and Vertical (Y, ΔY). Additionally oscilloscope channels can be displayed as binary or hex values. |
| Waveform math |
One function of 1-2, 1x2, FFT, differentiate, integrate. Source of FFT, differentiate, integrate: oscilloscope channels 1 or 2, 1-2, 1+2, 1x2. |
| FFT |
| Points |
Fixed at 1000 points |
| Source of FFT |
Scope channels 1 or 2 (or 3 or 4 on DSO50x4A only), 1+2, 1-2, 1*2 |
| Window |
Rectangular, flattop, hanning |
| Noise floor |
–50 to –90 dB depending on averaging |
| Amplitude |
Display in dBV, dBm at 50 Ω |
| Frequency resolution |
0.05/time per div |
| Maximum frequency |
50/time per div |
| Storage |
| Save/recall |
10 setups and traces can be saved and recalled using internal non-volatile memory. Optional secure environment mode ensures setups and traces are stored to internal volatile memory so data is erased when power is removed. Compliant to NISPOM Chapter 8 requirements. |
| Storage type and format |
USB 1.1 host ports on front and rear panels Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit) Data formats: X and Y (time/voltage) values in CSV format, ASCII XY format, BIN format Trace/setup formats: Recalled |
| I/O |
| Standard ports |
USB 2.0 high speed device, two USB 1.1 host ports, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output |
| Max transfer rate |
IEEE488.2 GPIB: 500 kbytes/sec USB (USBTMC-USB488): 3.5 Mbytes/sec 100 Mbps LAN (TCP/IP): 1 Mbytes/sec |
| Printer compatibility |
Selected HP Deskjet printers |
| General characteristics |
| Physical size |
35.4 cm wide x 18.8 cm high x 17.4 cm deep (without handle) 38.5 cm wide x 18.8 cm high x 17.4 cm deep (with handle) |
| Weight |
Net: 4.1 kg (9 lbs) Shipping: approximately 9 kgs (20 lbs) |
| Probe comp output frequency ~ |
1.2 kHz, amplitude ~2.5 V |
| Trigger out |
0 to 5 V into open circuit (~23 ns delay) 0 to 2.5 V into 50 Ω |
| Kensington lock |
Connection on rear panel for security |
| Power requirements |
| Line rating |
~Line 120 W max, 96-144 V/48-440 Hz, 192-288 V/48-66 Hz, automatic selection |
| Line frequency |
50/60 Hz, 100-240 VAC; 440 Hz, 100-132 VAC |
| Power usage |
110 W max |
| Environmental characteristics |
| Ambient temperature |
Operating –10° C to +55° C; non-operating –51° C to +71° C |
| Humidity |
Operating 95% RH at 40° C for 24 hour; non-operating 90% RH at 65° C for 24 hour |
| Altitude |
Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft) |
| Vibration |
Agilent class GP and MIL-PRF-28800F; Class 3 random |
| Shock |
Agilent class GP and MIL-PRF-28800F (operating 30 g, 1/2 sine, 11-ms duration, 3 shocks/axis along major axis. Total of 18 shocks) |
| Pollution degree |
Normally only dry non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation must be expected. |
| Indoor use |
Rated for indoor use only |
| Other |
| Measurement categories |
CAT I: Mains isolated CAT II: Line voltage in appliance and to wall outlet |
| Regulatory information |
Safety IEC 61010-1:2001 / EN 61010-1:2001 Canada: CSA C22.2 No. 61010-1:2004 USA: UL 61010-1:2004 |
| Supplementary information |
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly. The product was tested in a typical configuration with HP/Agilent test systems. Product specifications, characteristics, and descriptions in this document are subject to change without notice. |
* - Half channel is when only one channel of channel pair 1-2 is turned on, or one channel of channel pair 3-4 is turned on.
** - Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10° C from firmware calibration temperature.
*** - 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting.
|