Agilent DSO5012A 5000 Series
100 MHz 2 channels Oscilloscope with MegaZoom III technology
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Agilent DSO5012A 5000 Series
100 MHz 2 channels Oscilloscope with MegaZoom III technology




Click image to enlarge

 Agilent  DSO5012A

Features:
  • 100 MHz bandwidth
  • 2 channels
  • MegaZoom III memory and display technology, up to 4 GSa/s
  • Up to 1 Mpts acquisition memory
  • Up to 100,000 waveforms per second real-time update rate
  • Up to 12 bits of vertical resolution, even in single-shot acquisitions
  • Complete connectivity – USB (3 ports), LAN, GPIB
  • XGA display out
  • Full remote control, including web browser
  • LXI-C compliant
  • High-definition XGA (1024 x 768) display with 256 levels of intensity grading
  • Serial triggering and hardware-accelerated decode for I2C, SPI, CAN, LIN, and USB (trigger only) on 4-channel models


  Description

Leading-edge technology for all scope users

The 5000 Series oscilloscopes leverage the same third-generation MegaZoom III technology blocks used in our higher performance bench and lab oscilloscopes – responsive deep memory, fast update rates with minimal “dead time,” and analog-like display systems – and deliver them in a compact package, at a price similar to oscilloscopes with older technology blocks.

MegaZoom III technology provides industry-leading performance with the:

Industry-leading customer support

As the world’s leading test and measurement vendor, Agilent maintains the largest network of sales engineers, application engineers, support engineers and technicians. From pre-sales collaboration, to calibration, to training and consulting, to repair and servicing, Agilent stands with you throughout the life of your product. It’s no accident that Agilent has such loyal customers.




  Models, Options, & Accessories


Model Description List Price Sale Price
DSO5012A 100MHz, 2-channel Oscilloscope
$4151.00 
DSO5014A 100MHz, 4-channel Oscilloscope
$5023.00 
DSO5032A 300MHz, 2-channel Oscilloscope
$5637.00 
DSO5034A 300MHz, 4-channel Oscilloscope
$7072.00 
DSO5052A 500MHz, 2-channel Oscilloscoe
$8405.00 
DSO5054A 500MHz, 4-channel Oscilloscope
$10245.00 
Model Options List Price Sale Price
U1241A True-rms 10000 Count Handheld DMM
$200.00 
N5423A I2C and SPI Low Speed Serial Decode (4 channel 6000 series)
$1250.00 
N5424A CAN and LIN Automotive Serial Decode
$1250.00 
10073C 10:1, 1 MOhm, 1.5m, Passive Probe
$296.00 
N2863A DSO3000 10:1 passive probe 300MHz
$135.00 
N2916B Rackmount kit for 5000 and 6000 Series oscilloscopes
$690.00 
U3000A Electronic Instrumentation Training Kit
$200.00 



  Specifications

Acquisition
Sample rate DSO501xA/503xA: 2 GSa/a each channel
DSO505xA: 4 GSa/s half channel*, 2 GSa/s each channel
Equivalent-time sample rate 400 GSa/s (when real-time mode is turned off)
Memory depth 1 Mpts half channel*, 500 kpts each channel
Vertical resolution 8 bits, up to 12 in high-resolution or averaging modes
Peak detection DSO501xA: 1 ns peak detect
DSO503xA: 500 ps peak detect
DSO505xA: 250 ps peak detect
Averaging Selectable from 2, 4, 8, 16, 32, 64 … to 65536
High resolution mode Average mode with #avg = 1
12 bits of resolution when ≥10 μs/div, at 4 GSa/s or ≥20 μs/div, at 2 GSa/s
Filter Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of oscilloscope, whichever is less) with vectors on and in real-time mode
Vertical system
Scope channels DSO50x2A: 2 Ch 1 and 2 simultaneous acquisition
DSO50x4A: Ch 1, 2, 3, and 4 simultaneous acquisition
Bandwidth (–3dB)** DSO501xA: DC to 100 MHz
DSO503xA: DC to 300 MHz
DSO505xA: DC to 500 MHz
AC coupled DSO501xA: 3.5 Hz to 100 MHz
DSO503xA: 3.5 Hz to 300 MHz
DSO505xA: 3.5 Hz to 500 MHz
Calculated rise time (= 0.35/bandwidth) DSO501xA: 3.5 nsec
DSO503xA: 1.17 nsec
DSO505xA: 700 psec
Single-shot bandwidth DSO501xA: 100 MHz
DSO503xA: 300 MHz
DSO505xA: 500 MHz
Range*** 2 mV/div to 5 V/div (1 MΩ or 50 Ω)
Maximum input Maximum input voltage for analog inputs:
CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
CAT II 100 Vrms, 400 Vpk
with N2863A 10:1 probe: CAT I 600 V, CAT II 300 V (DC + peak AC)
with 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
with 50 Ω input: 5 Vrms, CAT I
Offset range ±5 V on ranges < 10 mV/div;
±20 V on ranges 10 mV/div to 200 mV/div;
±75 V on ranges >200 mV/div
Dynamic range ±8 div
Input impedance 1 MΩ ± 1% || 12 pF or 50 Ω ± 1.0%, selectable
Coupling AC, DC
BW limit 25 MHz selectable
Channel-to-channel isolation DC to max bandwidth > 40 dB
Standard probes DSO501xA: 10:1 N2863A shipped standard for each oscilloscope channel
DSO503xA: 10:1 N2863A shipped standard for each oscilloscope channel
DSO505xA: 10:1 10073C shipped standard for each oscilloscope channel
Probe ID Auto probe sense and AutoProbe interface
Agilent- and Tektronix-compatible passive probe sense
ESD tolerance ±2 kV
Noise peak-to-peak DSO501xA: 0.5% full scale or 250 μV, whichever is greater
DSO503xA: 0.5% full scale or 300 μV, whichever is greater
DSO505xA: 0.5% full scale or 360 μV, whichever is greater
DC vertical gain accuracy** ±2.0% full scale
DC vertical offset accuracy ≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value;
> 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
Single cursor accuracy*** ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)}
Example: for 50 mV signal, oscilloscope set to 10 mV/div (80 mV full scale), 5 mV offset,
accuracy = ±{2.0% (80 mV) + 0.1 (10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2%(80 mV)} = ± 4.785 mV
Dual cursor accuracy*** ±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)}
Example: for 50 mV signal, oscilloscope set to 10 mV/div (80 mV full scale), 5 mV offset,
accuracy = ±{2.0% (80 mV) + 0.4% (80 mV)} = ±1.92 mV
Horizontal
Range DSO501xA: 5 nsec/div to 50 sec/div
DSO503xA: 2 nsec/div to 50 sec/div
DSO505xA: 1 nsec/div to 50 sec/div
Resolution 2.5 psec
Timebase accuracy 25 ppm (0.0025%) to 40° C, plus 1 ppm per ° C from 40° C, to 55° C
Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on
Delay range Pre-trigger (negative delay): Greater of 1 screen width or 125 μs
Post-trigger (positive delay): 1 s to 500 seconds
Channel delta-t accuracy Same channel: ±0.0025% reading ±0.1% screen width ±20 ps
Channel-to-channel: ±0.0025% reading ±0.1% screen width ±40 ps
Same channel example (DSO505xA): For signal with pulse width of 10 μs, oscilloscope set to 5 μs/div
(50 μs screen width), delta-t accuracy = ±{0.0025% (10 μs) + 0.1% (50 μs) + 20 ps} = 50.27 ns
Modes Main, delayed, roll, XY
XY Bandwidth: Max bandwidth
Phase error at 1 MHz: < 0.5 degrees
Z Blanking: 1.4 V blanks trace (use external trigger on DSO50x2A, channel 4 on DSO50x4A)
Reference positions Left, center, right
Trigger system
Sources DSO50x2A: Ch 1, 2, line, ext
DSO50x4A: Ch 1, 2, 3, 4, line, ext
Modes Auto, normal (triggered), single
Holdoff time ~60 ns to 10 seconds
Trigger jitter 15 ps rms
Selections Edge, pulse width, pattern, TV, duration
Edge Trigger on a rising, falling, or alternating edge of any source
Pulse width Trigger when a positive- or negative-going pulse is less than, greater than, or within a specified range on any of the source channels.
Minimum pulse width setting:
5 ns (DSO501xA)
2 ns (DSO503xA, DSO505xA)
Maximum pulse width setting: 10 s
Pattern Trigger at the beginning of a pattern of high, low, and don't care levels and/or a rising or falling edge established across any of the channels, but only after a pattern has been established for a minimum of 2 nsec. The channel’s high or low level is defined by that channel’s trigger level.
TV Trigger using any oscilloscope channel on most analog progressive and interlaced video standards including HDTV/EDTV, NTSC, PAL, PAL-M or SECAM broadcast standards. Select either positive or negative sync pulse polarity. Modes supported include Field 1, Field 2, all fields, all lines, or any line within a field. TV trigger sensitivity 0.5 division of sync signal. Trigger holdoff time can be adjusted in half field increments.
Duration Trigger on a multi-channel pattern whose time duration is less than a value, greater than a value, greater than a time value with a timeout, or inside or outside of a set of time values.
Minimum duration setting: 2 ns
Maximum duration setting: 10 s
CAN Trigger on CAN (Controller Area Network) version 2.0A and 2.0B signals. Trigger on the start of frame (SOF) bit (standard). N5424A option supports triggering on remote frame ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame ID and data, error frame, all errors, acknowledge error and overload frame.
LIN Trigger on LIN (Local Interconnect Network) sync break at beginning of message frame (standard).
N5424A option supports triggering on frame ID.
USB Trigger on USB (Universal Serial Bus) start of packet, end of packet, reset complete, enter suspend, or exit suspend on the differential USB data lines. USB low speed and full speed are supported.
I2C Trigger on I2C (Inter-IC bus) serial protocol at a start/stop condition or user defined frame with address and/or data values. Also trigger on missing acknowledge, address with no acq, restart, EEPROM read, and 10-bit write.
SPI Trigger on SPI (Serial Protocol Interface) data pattern during a specific framing period. Supports positive and negative Chip Select framing as well as clock Idle framing and user-specified number of bits per frame.
AutoScale Finds and displays all active channels, sets edge trigger mode on highest-numbered channel, sets vertical sensitivity on channels, time base to display ~1.8 periods. Requires minimum voltage > 10 mVpp, 0.5% duty cycle and minimum frequency > 50 Hz.
Channel triggering
Range (internal) ±6 div from center screen
Sensitivity** < 10 mV/div: greater of 1 div or 5mV; ≥ 10 mV/div: 0.6 div
Coupling AC (~10 Hz), DC, noise reject, HF reject and LF reject (~50 kHz)
External (EXT) triggering DSO50x2A DSO50x4A
Input impedance 1 MΩ ±3% || 12 pF or 50 Ω ±1% 1.015 kΩ ±5%
Maximum input CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk V CAT II 100 Vrms, 400 Vpk
with N2863A 10:1 probe: CAT I 600 V, CAT II 300 V (DC + peak AC)
with 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
5 Vrms with 50-Ω input, CAT I
±15 V
Range DC coupling: trigger level ± 1 V and ± 8 V ±5 V
Sensitivity For ± 1V range setting:
DC to 100 MHz, 100 mV, >100 MHz to bandwidth of the oscilloscope, 200 mV
For ±8 V range setting:
DC to 100 MHz, 250 mV; >100 MHz to bandwidth of the oscilloscope, 500 mV
DC to 100 MHz, 500 mV
Coupling AC (~10 Hz), DC, noise reject, HF reject and LF reject (~50 kHz)  
Probe ID Auto probe sense and AutoProbe interface
Agilent- and Tektronix-compatible passive probe sense
 
Display system
Display 6.3-inch (161 mm) diagonal color TFT LCD
Display update rate Up to 100,000 waveforms/sec in real-time mode
Resolution XGA:
768 vertical by 1024 horizontal points (screen area);
640 vertical by 1000 horizontal points (waveform area)
256 levels of intensity scale
Controls Waveform intensity on front panel. Vectors on/off; infinite persistence on/off,
8 x 10 grid with intensity control
Built-in help system Key-specific help displayed by pressing and holding key or softkey of interest
Real-time clock Time and date (user adjustable)
Measurement features
Automatic measurements Measurements are continuously updated. Cursors track last selected measurement.
Voltage Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation
Time Frequency, period, + width, – width and duty cycle on any channel. Rise time, fall time, X at max Y (time at max volts), X at min Y (time at min volts), delay, and phase on oscilloscope channels only.
Counter Built-in 5-digit frequency counter on any channel. Counts up to the oscilloscope’s bandwidth.
Threshold definition Variable by percent and absolute value; 10%, 50%, 90% default for time measurements
Cursors Manually or automatically placed readout of Horizontal (X, ΔX, 1/ΔX) and Vertical (Y, ΔY). Additionally oscilloscope channels can be displayed as binary or hex values.
Waveform math One function of 1-2, 1x2, FFT, differentiate, integrate. Source of FFT, differentiate, integrate: oscilloscope channels 1 or 2, 1-2, 1+2, 1x2.
FFT
Points Fixed at 1000 points
Source of FFT Scope channels 1 or 2 (or 3 or 4 on DSO50x4A only), 1+2, 1-2, 1*2
Window Rectangular, flattop, hanning
Noise floor –50 to –90 dB depending on averaging
Amplitude Display in dBV, dBm at 50 Ω
Frequency resolution 0.05/time per div
Maximum frequency 50/time per div
Storage
Save/recall 10 setups and traces can be saved and recalled using internal non-volatile memory.
Optional secure environment mode ensures setups and traces are stored to internal volatile memory so data is erased when power is removed. Compliant to NISPOM Chapter 8 requirements.
Storage type and format USB 1.1 host ports on front and rear panels
Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit)
Data formats: X and Y (time/voltage) values in CSV format, ASCII XY format, BIN format
Trace/setup formats: Recalled
I/O
Standard ports USB 2.0 high speed device, two USB 1.1 host ports, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output
Max transfer rate IEEE488.2 GPIB: 500 kbytes/sec
USB (USBTMC-USB488): 3.5 Mbytes/sec
100 Mbps LAN (TCP/IP): 1 Mbytes/sec
Printer compatibility Selected HP Deskjet printers
General characteristics
Physical size 35.4 cm wide x 18.8 cm high x 17.4 cm deep (without handle)
38.5 cm wide x 18.8 cm high x 17.4 cm deep (with handle)
Weight Net: 4.1 kg (9 lbs)
Shipping: approximately 9 kgs (20 lbs)
Probe comp output frequency ~ 1.2 kHz, amplitude ~2.5 V
Trigger out 0 to 5 V into open circuit (~23 ns delay)
0 to 2.5 V into 50 Ω
Kensington lock Connection on rear panel for security
Power requirements
Line rating ~Line 120 W max, 96-144 V/48-440 Hz, 192-288 V/48-66 Hz, automatic selection
Line frequency 50/60 Hz, 100-240 VAC; 440 Hz, 100-132 VAC
Power usage 110 W max
Environmental characteristics
Ambient temperature Operating –10° C to +55° C;
non-operating –51° C to +71° C
Humidity Operating 95% RH at 40° C for 24 hour;
non-operating 90% RH at 65° C for 24 hour
Altitude Operating to 4,570 m (15,000 ft);
non-operating to 15,244 m (50,000 ft)
Vibration Agilent class GP and MIL-PRF-28800F; Class 3 random
Shock Agilent class GP and MIL-PRF-28800F (operating 30 g, 1/2 sine, 11-ms duration, 3 shocks/axis along major axis. Total of 18 shocks)
Pollution degree Normally only dry non-conductive pollution occurs.
Occasionally a temporary conductivity caused by condensation must be expected.
Indoor use Rated for indoor use only
Other
Measurement categories CAT I: Mains isolated
CAT II: Line voltage in appliance and to wall outlet
Regulatory information Safety IEC 61010-1:2001 / EN 61010-1:2001
Canada: CSA C22.2 No. 61010-1:2004
USA: UL 61010-1:2004
Supplementary information The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly.
The product was tested in a typical configuration with HP/Agilent test systems.
Product specifications, characteristics, and descriptions in this document are subject to change without notice.

  * - Half channel is when only one channel of channel pair 1-2 is turned on, or one channel of channel pair 3-4 is turned on.
  ** - Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10° C from firmware calibration temperature.
  *** - 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET