Agilent 681x Programming and Measurement Accuracy
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Agilent 681x Programming and Measurement Accuracy



  681x Programming Accuracy

  6811B 6812B 6813B
Programming accuracy (25º ± 5ºC)    
RMS voltage
(% of output + offset)
0.15% + 0.3 V
(45 - 100Hz)
0.15% + 0.3 V
(45 - 100Hz)
0.15% + 0.3 V
(45 - 100Hz)
0.5% + 0.3 V
(>100 - 500 Hz)
0.5% + 0.3 V
(>100 - 500 Hz)
0.5% + 0.3 V
(>100 - 500 Hz)
1% + 0.3 V
(> 500 - 1000 Hz)
1% + 0.3 V
(> 500 - 1000 Hz)
1% + 0.3 V
(> 500 - 1000 Hz)
dc voltage 0.1% + 0.5 V 0.1% + 0.5 V 0.5% + 0.3 V
Frequency 0.01% + 10μHz 0.01% + 10μHz 0.01% + 10μHz


  681x Measurement Accuracy

  6811B 6812B 6813B
Measurement accuracy (25º ± 5ºC)    
Rms. voltage (45 - 100 Hz) 0.03% + 100 mV1 0.03% + 100 mV1 0.03% + 100 mV1
dc voltage 0.05% + 150 mV1 0.05% + 150 mV1 0.05% + 150 mV1
RMS current (45 - 100 Hz)2
High range 0.05% + 10 mA 0.05% + 10 mA 0.05% + 10 mA
Low range 0.05% + 1.5 mA 0.05% + 1.5 mA 0.05% + 1.5 mA
Power (VA) (45-100 Hz)2
High range 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 12 mVA/V
Low range 0.1% + 1.5 VA + 1.2 mVA/V 0.1 % + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V
Power (watts) (45-100 Hz)2
High range 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 12 mW/V
Low range 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 1.2 mW/V
Frequency 0.01% + 0.01 Hz 0.01% + 0.01 Hz 0.01% + 0.01 Hz
Power factor 0.01 0.01 0.01
Current magnitude Fundamental 0.03% + 1.5 mA 0.03% + 1.5 mA 0.03% + 1.5 mA
Low range Harmonics 2-49 0.03% + 1 mA + 0.2%/kHz 0.03% + 1 mA + 0.2%/kHz 0.03% + 1 mA + 0.2%/kHz
Current magnitude Fundamental 0.05% + 5 mA 0.05% + 5 mA 0.05% + 5 mA
High range Harmonics 2-49 0.05% + 3 mA + 0.2%/kHz 0.05% + 3 mA + 0.2%/kHz 0.05% + 3 mA + 0.2%/kHz
  1. Product may be operated between dc and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 μ seconds per point. Frequency content of the measured signal must be limited to 4 k Hz or less to avoid aliasing effects.
  2. Select low measurement range for improved accuracy (10:1) for lower power measurements.



   