Agilent 6813B AC Power Source / Power Analyzer

Click image to enlarge
Agilent 6813B
|
|
Features:
- AC and DC output capability
- High-accuracy measurements
- Built-in harmonic analysis capability
- Arbitrary waveform generation
- Compact single-phase
- Built-in GPIB and RS-232 interface with SCPI programming
- Includes Graphical User Interface and VXIplug&play drivers
|
Description
The Agilent 6813B is ideal for applications such as power supply testing, UPS testing, avionics ATE, the testing of power factor corrected equipment and devices. Set up is made easy with the Graphical User Interface, which requires no programming. And protect your valuable prototypes and assemblies with the extensive set of protection features.
Save space on a lab bench or in a test rack with this flexible instrument, which can take the place of an AC source, DC source, powerful arbitrary waveform generator, as well as a sophisticated power analyzer. An optional second power analyzer is available, which can be used independently from the source, or for dual-node measurements such as power supply input/output efficiency tests.
The Complete ac Power Test Solution
Since your product will have to operate in the real world of unpredictable ac power, you need to design and verify its correct operation under a wide range of ac power inputs. Brownouts, dropouts, sags, and other irregularities are not unusual in many communities today. Agilent ac sources have the features needed to easily accomplish this test goal either in an R&D environment or on the manufacturing test floor. If you plan to sell your products in a worldwide market, you will also need to test them at the line voltages and frequencies that they will eventually operate at. There is also additional testing needed to meet regulatory requirements for sale into some countries.
Agilent ac sources offer a complete solution for ac power testing, helping you to simplify this important task. These instruments combine the features of a power amplifier and arbitrary waveform generator to give you the ability to do all of the tests that you need. There are many standard preprogrammed waveforms, or you can use the transient generation system to simulate sophisticated and repeatable ac line disturbances. dc power can also be generated, either as a dc offset or as a pure dc signal.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 6811B |
AC source/analyzer, 0-300 Vrms, 375 VA, single-phase. GPIB, RS-232. |
| $7194.60 |  |
|
| 6812B |
AC source/analyzer, 0-300 Vrms, 750 VA, single-phase. GPIB, RS-232. |
| $8783.25 |  |
|
| 6813B |
AC source/analyzer, 0-300 Vrms, 1750 VA, single-phase. GPIB, RS-232. |
| $12093.90 |  |
|
| Model |
Options |
List Price |
Sale Price |
| 6813B-1CM |
Rack mount kit (p/n 5062-3977) |
| $48.04 |  |
|
| 6813B-1CP |
Rack mount kit with handles (p/n 5062-3983) |
| $108.15 |  |
|
| 6813B-841 |
Power cord, Americas, Japan, NEMA 6-20P, 20A, 250V PLUG, 8ft, (p/n 8120-5572) - Discontinued - no replacement |
| 6813B-844 |
Power cord, Americas, Japan, NEMA L6-30P, 30A, 250V, 10AWG, 8.2ft p/n 8120-6507 - Discontinued - no replacement |
| 6813B-A6J |
ANSI/NCSL Z540 calibration certificate |
| $366.45 |  |
|
| 6813B-UK6 |
Commercial calibration with test result data |
| $154.35 |  |
|
Specifications
Supplemental characteristics
| |
6811B |
6812B |
6813B |
| Number of phases |
1 |
1 |
1 |
| Output ratings (Maximum) |
| Power |
375 VA |
750 VA |
1750 VA |
| rms voltage |
300 V |
300 V |
300 V |
| rms current |
3.25 A |
6.5 A |
13 A |
| Repetitive & non-repetitive peak current |
40 A |
40 A |
80 A |
| Crest factor |
12 |
6 |
6 |
| Load Power factor capability |
0 to 1 |
0 to 1 |
0 to 1 |
| dc power |
285 W |
575 W |
1350 W |
| dc voltage |
±425 V |
±425 V |
±425 V |
| dc current |
2.5 A |
5.0 A |
10.0 A |
| Output frequency range1 |
dc; 45 Hz to 1 kHz |
dc; 45 Hz to 1 kHz |
dc; 45 Hz to 1 kHz |
| Constant voltage ripple and noise (20 kHz to 10 MHz) |
-60 dB (relative to full scale) |
-60 dB (relative to full scale) |
-60 dB (relative to full scale) |
| Line regulation (% of full scale) |
0.1% |
0.1% |
0.1% |
| Load regulation (% of full scale) |
0.5% |
0.5% |
0.5% |
| Maximum total harmonic distortion |
0.25% at 50/60 Hz 1% worst case 45 to 1 kHz |
0.25% at 50/60 Hz 1% worst case 45 to 1 kHz |
0.25% at 50/60 Hz 1% worst case 45 to 1 kHz |
- Product may be operated between dc and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 μ seconds per point. Frequency content of the measured signal must be limited to 4 k Hz or less to avoid aliasing effects.
|