Agilent 66319D Dual Output Mobile Commmunication

Click image to enlarge
Agilent 66319D
|
|
Features:
- Programmable output resistance (-0.04 Ω to 1 Ω)
- Improved transient response <20 us
- Very low transient voltage drop <30 mV
- Programmable output response compensation
- Stable output for either long or short load leads
- Improved standby current measurement accuracy (New ±1A range)
- Simulate internal battery resistance of Ni-Cad, Ni-mh, Li-Ion, Li-Polymer batteries
- Negative resistance programming provides load lead voltage drop compensation from the wiring between the test fixture and actual wireless device
- 5 A peak current sourcing for next generation data transmission formats
- Programmable output response compensation to insure stable output operation for either long or short wiring
- Precision uA, mA, Amp measurement for "sleep mode," "standby mode" and "talk mode" battery current draw characterization
- Log current and voltage waveforms from seconds to weeks (requires 14565A Device Characterization Software or Option 053)
- Visualize complex pulsed current waveforms using CCDF display (requires 14565A Device Characterization Software or Option 053)
|
Description
The Agilent 66319D dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a ½ rack box) and eliminates the need for two separate power supplies. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. The 66319D dc source provides all of the capabilities of the 66319B with the addition of a built-in digital voltmeter.
The 66319D includes a new Agilent-developed feature that enables cellular-telephone manufacturers to detect permanently and intermittently open-sense wire connections automatically. Detection of open-sense wire connections allows users to prevent incorrect battery-charger calibration, incorrect test results and low-voltage phone shutdown due to a large transient voltage drop. This diagnostic capability helps manufacturers avoid shipping low-quality products and allows for more reliable testing and accurate measurements.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 66309B |
Mobile communication dc source, dual-output 15V/3A,12V/1.5A. GPIB. |
| $3049.20 |  |
|
| 66309D |
Mobile communication dc source, dual-output 15V/3A,12V/1.5A, with DVM. GPIB. |
| $3416.70 |  |
|
| 66311B |
Mobile communication dc source, 15Vdc/3A. GPIB, RS-232. |
| $2202.90 |  |
|
| 66311D |
Mobile communication dc source, 15V/3A with DVM. G - Discontinued - no replacement |
| 66319B |
Mobile communication dc source. Dual-output. 15Vdc, 3A; 12Vdc, 1.5A, GPIB |
| $3216.15 |  |
|
| 66319D |
Mobile communication dual-output dc source, with battery emulation, DVM. GPIB. |
| $3562.65 |  |
|
| Model |
Options |
List Price |
Sale Price |
| 66319D-1CM |
Rackmount kit (p/n 5062-3972) includes blank filler panel |
| $69.90 |  |
|
| 66319D-521 |
Add solid state output disconnect relays |
| $172.20 |  |
|
| 66319D-A6J |
ANSI/NCSL Z540 calibration certificate |
| $355.95 |  |
|
| 66319D-AXS |
Rack mount kit for side by side mounting (p/n 5062-3974, p/n 5061-9694) |
| $92.82 |  |
|
| 66319D-UK6 |
Commercial calibration with test results data |
| $150.15 |  |
|
Specifications
| |
66309B
66309D |
66311B
66311D |
66319B
66319D |
66321B/D |
66332A |
66332AJ01 |
| Number of outputs |
2 |
1 |
2 |
1 |
1 |
1 |
| GPIB |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Output ratings |
| Voltage |
0 to 15 V |
0 to 15 V |
0 to 15 V |
0 to 15 V |
0 to 20 V |
0 to 30 V |
| Current |
0 to 3 A |
0 to 3 A |
0 to 3 A |
0 to 3 A |
0 to 5 A |
0 to 3.3 A |
| Peak current for up to 7 ms |
5 A |
5 A |
5 A |
5 A |
5 A |
3.3 A |
| Programming accuracy at 25°C ±5°C (% of setting plus fixed) |
| Voltage |
0.05%+ |
10 mV |
10 mV |
10 mV |
10 mV |
10 mV |
15 mV |
| +Current |
0.05%+ |
1.33 mA |
1.33 mA |
1.33 mA |
1.33 mA |
2 mA |
2 mA |
| Ripple and Noise (20 Hz to 20 MHz) |
| Voltage |
rms |
1 mV |
1 mV |
1 mV |
1 mV |
0.3 mV |
0.5 mV |
| peak-to-peak |
6 mV |
6 mV |
6 mV |
6 mV |
3 mV |
5 mV |
| Current |
rms |
2 mA |
2 mA |
2 mA |
2 mA |
2 mA |
2 mA |
| dc measurement accuracy |
| Voltage |
0.03%+ |
5 mV |
5 mV |
5 mV |
5 mV |
3 mV |
5 mV |
| +20 mA to + rated current |
0.2%+ |
0.5 mA2 |
0.5 mA2 |
|
|
0.5 mA |
0.5 mA |
| -20 mA to - rated current |
0.2%+ |
1.1 mA |
1.1 mA |
|
|
1.1 mA |
1.1 mA |
| -3 A to + 5 A |
0.2% |
|
|
0.5 mA2 |
0.5 mA2 |
|
|
| -1 A to + 1 A |
0.1% |
|
|
0.2 mA |
0.2 mA |
|
|
| -20 mA to + 20 mA range |
0.1%+ |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
| Dynamic measurement system |
| Buffer size |
4096 points |
4096 points |
4096 points |
4096 points |
4096 points |
4096 points |
| Sampling interval |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
| Transient response time |
<35 μs3 |
<35 μs3 |
<20 μs3 |
<20 μs |
<100 μs4 |
<100 μs4 |
| Transient voltage dip (typical with up to 15 feet 22 AWG wiring) |
70 mV |
70 mV |
40 mV |
40 mV |
500 mV |
650 mV |
| Programmable output resistance |
| Range |
|
|
-40 mΩ to +1 Ω |
-40 mΩ to +1 Ω |
|
|
| Programming accuracy |
|
|
0.5% + 2 mΩ |
0.5% + 2 mΩ |
|
|
| Resolution |
|
|
1 mΩ |
1 mΩ |
|
|
| Voltmeter input (66309D, 66319D, 66311D and 66321D only) |
| Input range |
-25 to +25 Vdc |
-25 to +25 Vdc |
-25 to +25 Vdc |
-25 to +25 Vdc |
|
|
| dc readback accuracy (at 25ºC ±5ºC) |
0.04% + 5 mV |
0.04% + 5 mV |
0.04% + 5 mV |
0.04% + 5 mV |
|
|
| ac + dc readback accuracy (at 25ºC ±5ºC) with dc plus a sinewave input > 25 mV rms |
1% + 5 mV (60 Hz to 10 kHz) |
1% + 5 mV (60 Hz to 10 kHz) |
1% + 5 mV (60 Hz to 10 kHz) |
1% + 5 mV (60 Hz to 10 kHz) |
|
|
| Auxilary output (66309B/D and 66319B/D) |
| Output ratings |
Voltage |
0 to 12V |
|
0 to 12V |
|
|
|
| Current |
0 to 1.5 A |
|
0 to 1.5 A |
|
|
|
| Programming accuracy |
Voltage |
0.2% + 40 mV |
|
0.2% + 40 mV |
|
|
|
| +Current |
0.2% + 4.5 mA |
|
0.2% + 4.5 mA |
|
|
|
| dc measurement accuracy |
Voltage |
0.2% + 15 mV |
|
0.2% + 15 mV |
|
|
|
| +Current |
0.2% + 3 mA |
|
0.2% + 3 mA |
|
|
|
| Ripple and Noise (20 Hz to 20 MHz) |
| Voltage |
rms |
1 mV |
|
1 mV |
|
|
|
| peak-to-peak |
6 mV |
|
6 mV |
|
|
|
| Current |
rms |
2 mA |
|
2 mA |
|
|
|
- 66332A also has RS-232 interface
- Applies with current detector set to dc
- Time for the output voltage to recover to within 20 mV of final value after 0.1 to 1.5 A load change in
high capacitance compensation range.
- Time for the output voltage to recover to within 20 mV or 0.1% of the voltage rating of the unit following a change in load current of up to 50% of the output current rating.
|