company logo Agilent 66319B
Dual Mobile Communications
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Agilent 66319B
Dual Mobile Communications




Click image to enlarge

 Agilent 66319B

Data sheet
Product overview

Additional photos
Click image to enlarge

Features:

  • Programmable output resistance (-0.04 Ω to 1 Ω)
  • Improved transient response <20 us
  • Very low transient voltage drop <30 mV
  • Programmable output response compensation
  • Stable output for either long or short load leads
  • Improved standby current measurement accuracy (New ±1A range)
  • Simulate internal battery resistance of Ni-Cad, Ni-mh, Li-Ion, Li-Polymer batteries
  • Negative resistance programming provides load lead voltage drop compensation from the wiring between the test fixture and actual wireless device
  • 5 A peak current sourcing for next generation data transmission formats
  • Programmable output response compensation to insure stable output operation for either long or short wiring
  • Precision uA, mA, Amp measurement for "sleep mode," "standby mode" and "talk mode" battery current draw characterization
  • Log current and voltage waveforms from seconds to weeks (requires 14565A Device Characterization Software or Option 053)
  • Visualize complex pulsed current waveforms using CCDF display (requires 14565A Device Characterization Software or Option 053)



  Description

The Agilent 66319B dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a ½ rack box) and eliminates the need for two separate power supplies. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring.

The 66319B includes a new Agilent-developed feature that enables cellular-telephone manufacturers to detect permanently and intermittently open-sense wire connections automatically. Detection of open-sense wire connections allows users to prevent incorrect battery-charger calibration, incorrect test results and low-voltage phone shutdown due to a large transient voltage drop. This diagnostic capability helps manufacturers avoid shipping low-quality products and allows for more reliable testing and accurate measurements.



  Models, Options, & Accessories


Model Description List Price Sale Price
66309B Mobile communication dc source, dual-output 15V/3A,12V/1.5A. GPIB.
$3049.20 
66309D Mobile communication dc source, dual-output 15V/3A,12V/1.5A, with DVM. GPIB.
$3416.70 
66311B Mobile communication dc source, 15Vdc/3A. GPIB, RS-232.
$2202.90 
66311D Mobile communication dc source, 15V/3A with DVM. G - Discontinued - no replacement
66319B Mobile communication dc source. Dual-output. 15Vdc, 3A; 12Vdc, 1.5A, GPIB
$3216.15 
66319D Mobile communication dual-output dc source, with battery emulation, DVM. GPIB.
$3562.65 
Model Options List Price Sale Price
66319B-1CM Rackmount kit (p/n 5062-3972) includes blank filler panel
$69.90 
66319B-521 Add solid state output disconnect relays
$172.20 
66319B-A6J ANSI/NCSL Z540 calibration certificate
$355.95 
66319B-AXS Rack mount kit for side by side mounting (p/n 5062-3974, p/n 5061-9694)
$92.82 
66319B-UK6 Commercial calibration with test results data
$150.15 



  Specifications

  66309B
66309D
66311B
66311D
66319B
66319D
66321B/D 66332A 66332AJ01
Number of outputs 2 1 2 1 1 1
GPIB Yes Yes Yes Yes Yes Yes
Output ratings
Voltage 0 to 15 V 0 to 15 V 0 to 15 V 0 to 15 V 0 to 20 V 0 to 30 V
Current 0 to 3 A 0 to 3 A 0 to 3 A 0 to 3 A 0 to 5 A 0 to 3.3 A
Peak current for up to 7 ms 5 A 5 A 5 A 5 A 5 A 3.3 A
Programming accuracy at 25°C ±5°C (% of setting plus fixed)
Voltage 0.05%+ 10 mV 10 mV 10 mV 10 mV 10 mV 15 mV
+Current 0.05%+ 1.33 mA 1.33 mA 1.33 mA 1.33 mA 2 mA 2 mA
Ripple and Noise (20 Hz to 20 MHz)
Voltage rms 1 mV 1 mV 1 mV 1 mV 0.3 mV 0.5 mV
peak-to-peak 6 mV 6 mV 6 mV 6 mV 3 mV 5 mV
Current rms 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA
dc measurement accuracy
Voltage 0.03%+ 5 mV 5 mV 5 mV 5 mV 3 mV 5 mV
+20 mA to + rated current 0.2%+ 0.5 mA2 0.5 mA2 0.5 mA 0.5 mA
-20 mA to - rated current 0.2%+ 1.1 mA 1.1 mA 1.1 mA 1.1 mA
-3 A to + 5 A 0.2% 0.5 mA2 0.5 mA2
-1 A to + 1 A 0.1% 0.2 mA 0.2 mA
-20 mA to + 20 mA range 0.1%+ 2.5 μA 2.5 μA 2.5 μA 2.5 μA 2.5 μA 2.5 μA
Dynamic measurement system
Buffer size 4096 points 4096 points 4096 points 4096 points 4096 points 4096 points
Sampling interval 15 μs -31,200 s 15 μs -31,200 s 15 μs -31,200 s 15 μs -31,200 s 15 μs -31,200 s 15 μs -31,200 s
Transient response time <35 μs3 <35 μs3 <20 μs3 <20 μs <100 μs4 <100 μs4
Transient voltage dip (typical with up to 15 feet 22 AWG wiring) 70 mV 70 mV 40 mV 40 mV 500 mV 650 mV
Programmable output resistance
Range -40 mΩ to +1 Ω -40 mΩ to +1 Ω
Programming accuracy 0.5% +
2 mΩ
0.5% +
2 mΩ
Resolution 1 mΩ 1 mΩ
Voltmeter input (66309D, 66319D, 66311D and 66321D only)
Input range -25 to +25 Vdc -25 to +25 Vdc -25 to +25 Vdc -25 to +25 Vdc
dc readback accuracy (at 25ºC ±5ºC) 0.04% + 5 mV 0.04% + 5 mV 0.04% + 5 mV 0.04% + 5 mV
ac + dc readback accuracy (at 25ºC ±5ºC) with dc plus a sinewave input > 25 mV rms 1% + 5 mV (60 Hz to 10 kHz) 1% + 5 mV (60 Hz to 10 kHz) 1% + 5 mV (60 Hz to 10 kHz) 1% + 5 mV (60 Hz to 10 kHz)
Auxilary output (66309B/D and 66319B/D)
Output ratings Voltage 0 to 12V 0 to 12V
Current 0 to 1.5 A 0 to 1.5 A
Programming accuracy Voltage 0.2% + 40 mV 0.2% + 40 mV
+Current 0.2% + 4.5 mA 0.2% + 4.5 mA
dc measurement accuracy Voltage 0.2% + 15 mV 0.2% + 15 mV
+Current 0.2% + 3 mA 0.2% + 3 mA
Ripple and Noise (20 Hz to 20 MHz)
Voltage rms 1 mV 1 mV
peak-to-peak 6 mV 6 mV
Current rms 2 mA 2 mA
  1. 66332A also has RS-232 interface
  2. Applies with current detector set to dc
  3. Time for the output voltage to recover to within 20 mV of final value after 0.1 to 1.5 A load change in high capacitance compensation range.
  4. Time for the output voltage to recover to within 20 mV or 0.1% of the voltage rating of the unit following a change in load current of up to 50% of the output current rating.




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET