Features:
- 5 A peak current sourcing for next generation data transmission formats
- Excellent transient voltage response characteristics prevent test interruptions due to triggering low voltage phone shutdown
- Up to 2.8 A current sinking to test built-in battery chargers
- Fast transient response, rapid command processing, and high speed output programming time maximize manufacturing test throughput
- Low power supply output noise assures less interference with phone operations
- Precision µA measurement for "sleep mode" characterization
- Dynamic current pulse measurements for battery loading information
- Precision voltage measurement for accurate tracking of charger voltage levels
- Automatically detects open sense wire connections
- Visualize and characterize current and voltage waveforms (requires 14565A Device Characterization Software)
|
Description
|
The Agilent 66311B mobile communications DC source provides fast transient, exceptional sourcing, and precision measurement. This product is specially designed for testing digital wireless communications products. The 66311B mobile communications DC source offers a new capability to automatically detect open sense connections. This new feature is an Agilent proprietary technology that helps test engineers avoid improper remote voltage settings and guarantees correct calibration of charger circuitry of the device-under test.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 66309B |
Mobile communication dc source, dual-output 15V/3A,12V/1.5A. GPIB. |
| $3049.20 |  |
|
| 66309D |
Mobile communication dc source, dual-output 15V/3A,12V/1.5A, with DVM. GPIB. |
| $3416.70 |  |
|
| 66311B |
Mobile communication dc source, 15Vdc/3A. GPIB, RS-232. |
| $2202.90 |  |
|
| 66311D |
Mobile communication dc source, 15V/3A with DVM. G - Discontinued - no replacement |
| 66319B |
Mobile communication dc source. Dual-output. 15Vdc, 3A; 12Vdc, 1.5A, GPIB |
| $3216.15 |  |
|
| 66319D |
Mobile communication dual-output dc source, with battery emulation, DVM. GPIB. |
| $3562.65 |  |
|
| Model |
Options |
List Price |
Sale Price |
| 66311B-1CM |
Rackmount kit (p/n 5062-3972) includes blank filler panel |
| $73.33 |  |
|
| 66311B-A6J |
ANSI/NCSL Z540 calibration certificate |
| $374.85 |  |
|
| 66311B-AXS |
Rack mount kit for side by side mounting (p/n 5062-3974, p/n 5061-9694) |
| $97.40 |  |
|
| 66311B-UK6 |
Commercial calibration with test results data |
| $158.55 |  |
|
Specifications
| |
66309B
66309D |
66311B
66311D |
66319B
66319D |
66321B/D |
66332A |
66332AJ01 |
| Number of outputs |
2 |
1 |
2 |
1 |
1 |
1 |
| GPIB |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Output ratings |
| Voltage |
0 to 15 V |
0 to 15 V |
0 to 15 V |
0 to 15 V |
0 to 20 V |
0 to 30 V |
| Current |
0 to 3 A |
0 to 3 A |
0 to 3 A |
0 to 3 A |
0 to 5 A |
0 to 3.3 A |
| Peak current for up to 7 ms |
5 A |
5 A |
5 A |
5 A |
5 A |
3.3 A |
| Programming accuracy at 25°C ±5°C (% of setting plus fixed) |
| Voltage |
0.05%+ |
10 mV |
10 mV |
10 mV |
10 mV |
10 mV |
15 mV |
| +Current |
0.05%+ |
1.33 mA |
1.33 mA |
1.33 mA |
1.33 mA |
2 mA |
2 mA |
| Ripple and Noise (20 Hz to 20 MHz) |
| Voltage |
rms |
1 mV |
1 mV |
1 mV |
1 mV |
0.3 mV |
0.5 mV |
| peak-to-peak |
6 mV |
6 mV |
6 mV |
6 mV |
3 mV |
5 mV |
| Current |
rms |
2 mA |
2 mA |
2 mA |
2 mA |
2 mA |
2 mA |
| dc measurement accuracy |
| Voltage |
0.03%+ |
5 mV |
5 mV |
5 mV |
5 mV |
3 mV |
5 mV |
| +20 mA to + rated current |
0.2%+ |
0.5 mA2 |
0.5 mA2 |
|
|
0.5 mA |
0.5 mA |
| -20 mA to - rated current |
0.2%+ |
1.1 mA |
1.1 mA |
|
|
1.1 mA |
1.1 mA |
| -3 A to + 5 A |
0.2% |
|
|
0.5 mA2 |
0.5 mA2 |
|
|
| -1 A to + 1 A |
0.1% |
|
|
0.2 mA |
0.2 mA |
|
|
| -20 mA to + 20 mA range |
0.1%+ |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
| Dynamic measurement system |
| Buffer size |
4096 points |
4096 points |
4096 points |
4096 points |
4096 points |
4096 points |
| Sampling interval |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
15 μs -31,200 s |
| Transient response time |
<35 μs3 |
<35 μs3 |
<20 μs3 |
<20 μs |
<100 μs4 |
<100 μs4 |
| Transient voltage dip (typical with up to 15 feet 22 AWG wiring) |
70 mV |
70 mV |
40 mV |
40 mV |
500 mV |
650 mV |
| Programmable output resistance |
| Range |
|
|
-40 mΩ to +1 Ω |
-40 mΩ to +1 Ω |
|
|
| Programming accuracy |
|
|
0.5% + 2 mΩ |
0.5% + 2 mΩ |
|
|
| Resolution |
|
|
1 mΩ |
1 mΩ |
|
|
| Voltmeter input (66309D, 66319D, 66311D and 66321D only) |
| Input range |
-25 to +25 Vdc |
-25 to +25 Vdc |
-25 to +25 Vdc |
-25 to +25 Vdc |
|
|
| dc readback accuracy (at 25ºC ±5ºC) |
0.04% + 5 mV |
0.04% + 5 mV |
0.04% + 5 mV |
0.04% + 5 mV |
|
|
| ac + dc readback accuracy (at 25ºC ±5ºC) with dc plus a sinewave input > 25 mV rms |
1% + 5 mV (60 Hz to 10 kHz) |
1% + 5 mV (60 Hz to 10 kHz) |
1% + 5 mV (60 Hz to 10 kHz) |
1% + 5 mV (60 Hz to 10 kHz) |
|
|
| Auxilary output (66309B/D and 66319B/D) |
| Output ratings |
Voltage |
0 to 12V |
|
0 to 12V |
|
|
|
| Current |
0 to 1.5 A |
|
0 to 1.5 A |
|
|
|
| Programming accuracy |
Voltage |
0.2% + 40 mV |
|
0.2% + 40 mV |
|
|
|
| +Current |
0.2% + 4.5 mA |
|
0.2% + 4.5 mA |
|
|
|
| dc measurement accuracy |
Voltage |
0.2% + 15 mV |
|
0.2% + 15 mV |
|
|
|
| +Current |
0.2% + 3 mA |
|
0.2% + 3 mA |
|
|
|
| Ripple and Noise (20 Hz to 20 MHz) |
| Voltage |
rms |
1 mV |
|
1 mV |
|
|
|
| peak-to-peak |
6 mV |
|
6 mV |
|
|
|
| Current |
rms |
2 mA |
|
2 mA |
|
|
|
- 66332A also has RS-232 interface
- Applies with current detector set to dc
- Time for the output voltage to recover to within 20 mV of final value after 0.1 to 1.5 A load change in
high capacitance compensation range.