Agilent 6551A 500 Watt Power Supply

Click image to enlarge
Agilent 6551A
|
|
Features:
- Analog programming of output voltage and current
- Self-test initiated at power-up
- Electronic calibration from front panel
- Five nonvolatile store and recall states
- User-defined power-on state
- Fan-speed control to minimize acoustic noise
- Auto-parallel of up to three 655xAs
- Over-voltage and over-current protection
- Over-temperature protection
Warranty:
1 year
|
Description
The Agilent 6551A models are 500 Watt, single output, series pass regulated power supplies, with front panel and analog programming of output voltage and current. Up to five front panel settings can be stored in nonvolatile storage registers for later recall.
This reliable series of 500 W dc power supplies can be controlled
either from the front panel or via an analog programming voltage. When
used in a test system, the fast up and down programming helps
decrease test time. Quickly reacting protection features, including fast
crowbar, CV/CC mode crossover and over-voltage protection help protect
your valuable assemblies from damage. The linear topology produces
very low ripple and noise, which allows you to make extremely accurate
measurements of the devices which you are testing.
Lab bench use is enhanced by the fan speed control, which helps to
minimize the acoustic noise.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 6551A |
DC power supply, 0-8 V, 0-50 A, 400 W. Manually controlled. |
| $3555.30 |  |
|
| 6552A |
DC power supply, 0-20 V, 0-25 A, 500 W. Manually controlled. |
| $3555.30 |  |
|
| 6553A |
DC power supply, 0-35 V, 0-15 A, 525 W. Manually controlled. |
| $3555.30 |  |
|
| 6554A |
DC power supply, 0-60 V, 0-9 A, 540 W. Manually controlled. |
| $3555.30 |  |
|
| 6555A |
DC power supply, 0-120 V, 0-4 A, 480 W. Manually controlled. |
| $3555.30 |  |
|
| Model |
Options |
List Price |
Sale Price |
| 6551A-908 |
Rack mount kit (p/n 5062-3977) |
| $50.33 |  |
|
| 6551A-909 |
Rack mount kit with handles (p/n 5062-3983) |
| $113.40 |  |
|
| 6551A-A6J |
ANSI/NCSL Z540 calibration certificate |
| $373.80 |  |
|
| 6551A-J01 |
Voltage increased to 10 V, current remains 50 A; 500 Watts, temp reduced |
| $421.05 |  |
|
| 6551A-J03 |
Current increased to 60A, voltage reduced to 6 V; 360 Watts, temp reduced |
| $421.05 |  |
|
| 6551A-UK6 |
Commercial calibration with test result data |
| $157.50 |  |
|
Specifications
(at 0º to 55ºC unless otherwise specified)
Supplemental characteristics
| |
6551A |
6552A |
6553A |
6554A |
6555A |
| Number of outputs |
1 |
1 |
1 |
1 |
1 |
| GPIB |
No |
No |
No |
No |
No |
| Output ratings |
| Output voltage |
0 to 8 V |
0 to 20 V |
0 to 35 V |
0 to 60 V |
0 to 120 V |
| Output current (40ºC) |
0 to 50 A |
0 to 25 A |
0 to 15 A |
0 to 9 A |
0 to 4 A |
| Maximum current (50ºC/55ºC) |
45 A/42.5 A |
22.5 A/21.3 A |
13.5 A/12.8 A |
8.1 A/7.7 A |
3.6 A/3.4 A |
| Programming accuracy at 25ºC ± 5ºC |
| Voltage |
0.06% + |
5 mV |
10 mV |
15 mV |
26 mV |
51 mV |
| Current |
0.15% + |
60 mA |
25 mA |
13 mA |
8 mA |
4 mA |
| Ripple and noise from 20 Hz to 20 MHz |
| Voltage rms |
300 μV |
300 μV |
400 μV |
500 μV |
700 μV |
| peak-peak |
3 mV |
3 mV |
4 mV |
5 mV |
7 mV |
| Current rms |
25 mA |
10 mA |
5 mA |
3 mA |
2 mA |
| Load regulation |
| Voltage |
1 mV |
2 mV |
3 mV |
4 mV |
5 mV |
| Current |
2 mA |
1 mA |
0.5 mA |
0.5 mA |
0.5 mA |
| Line regulation |
| Voltage |
0.5 mV |
0.5 mV |
1 mV |
1mV |
2 mV |
| Current |
2 mA |
1 mA |
0.75 mA |
0.5 mA |
0.5 mA |
| Transient response time |
Less than 100 μs for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current. |
|